<?xml version="1.0" encoding="UTF-8"?>
<!-- GXML Toolbox V3.13 R20101116;  http://www.gaeb-toolbox.de/  -->
<GAEB xmlns="http://www.gaeb.de/GAEB_DA_XML/200407"><GAEBInfo><Version>3.1</Version><VersDate>2009-12</VersDate><Date>2026-04-30</Date><Time>15:21:00</Time><ProgSystem>/ GXML Toolbox V3.13 R20101116</ProgSystem><ProgName>ORCA AVA Professional Edition 17.00.000.19</ProgName></GAEBInfo><PrjInfo><NamePrj>2025-03</NamePrj><LblPrj>Walldorf Astoriahalle Oberlichter</LblPrj><Cur>EUR</Cur><CurLbl>Euro</CurLbl></PrjInfo><Award><DP>83</DP><AwardInfo><Cat>SelectCall</Cat><Cur>EUR</Cur><CurLbl>Euro</CurLbl><SubmLoc/></AwardInfo><BoQ ID="id1"><BoQInfo><Name>01</Name><LblBoQ>Oberlichter</LblBoQ><OutlCompl>AllTxt</OutlCompl><BoQBkdn><Type>BoQLevel</Type><LblBoQBkdn>Titel</LblBoQBkdn><Length>2</Length><Num>No</Num></BoQBkdn><BoQBkdn><Type>BoQLevel</Type><LblBoQBkdn>Bereich</LblBoQBkdn><Length>2</Length><Num>No</Num></BoQBkdn><BoQBkdn><Type>Item</Type><Length>4</Length><Num>Yes</Num></BoQBkdn><BoQBkdn><Type>Index</Type><Length>1</Length><Num>No</Num></BoQBkdn><NoUPComps>2</NoUPComps><LblUPComp1>Material</LblUPComp1><LblUPComp2>Lohn</LblUPComp2><LblTime>Stunden       </LblTime></BoQInfo><BoQBody><Remark ID="id2"><Description><CompleteText><DetailTxt><Text><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;font-weight:bold;">1.  Ort der Baumaßnahme </span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Astoria-Halle Walldorf</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Schwetzinger Straße 91</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">69190 Walldorf</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;font-weight:bold;">2.  Baumaßnahme</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Gegenstand der Baumaßnahme ist die Sanierung der Oberlichtbänder über der Sporthalle und über dem Foyer der Astoria-Halle Walldorf und die damit verbundenen Sicherheitsmaßnahmen.</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;font-weight:bold;">3.  Bestandsgebäude</span></p><p style="text-align:left;margin-bottom:14pt;line-height:14pt;"><span style="font-family:Arial;font-size:10pt;">Die Astoria-Halle in Walldorf wurde 2007 errichtet. Der mehrgeschossige Bau beinhaltet eine Mehrzweckhalle und eine Dreifachsporthalle mit gemeinsam oder getrennt nutzbaren Foyer sowie Gastronomie und Kegelbahn mit allen jeweils nötigen Nebenräumen. Der Boden der Sporthalle liegt im UG, so dass sie sich nach außen zusammen mit dem Foyer als eingeschossiger Bau darstellt. Die Mehrzweckhalle stellt sich dagegen nach außen als zweigeschossiger Körper dar. Die Kegelbahn und die Nebenräume der Sporthalle liegen im UG.</span></p><p style="text-align:left;margin-bottom:14pt;line-height:14pt;"><span style="font-family:Arial;font-size:10pt;">Die Dachflächen des Gebäudes sind als Flachdach konstruiert und werden jeweils von einer Stahlkonstruktion getragen. Im Bereich der Sporthalle stoßen die Stahlträger durch den Dachaufbau und sind so von außen sichtbar. Zwischen den Trägern liegen insgesamt zwölf Oberlichtbänder. Das kleine Foyer der Sporthalle wird mit drei Lichtkuppeln auf dem Dach belichtet, das große Foyer der Mehrzweckhalle durch ein Oberlichtband. Auf dem Dach der Mehrzweckhalle befinden sich ebenfalls Lichtkuppeln und zusätzlich Photovoltaikanlagen. Die Dachfläche von Foyer und Sporthalle ist im Bereich der Sporthalle bekiest und im Bereich des Foyers begrünt und beherbergt dort zusätzlich eine Dachterrasse. Die Dachfläche der Mehrzweckhalle ist begrünt.</span></p><p style="text-align:left;line-height:14pt;"><span style="font-family:Arial;font-size:10pt;text-decoration:underline;">Bestehender Dachaufbau</span></p><p style="text-align:left;line-height:14pt;"><span style="font-family:Arial;font-size:10pt;font-style:italic;">Dachfläche über Sporthalle</span></p><p style="text-align:left;margin-bottom:14pt;line-height:14pt;"><span style="font-family:Arial;font-size:10pt;">Der Dachaufbau über der Mehrzweckhalle besteht aus quer zur Halle liegenden Stahl-Fachwerkträgern, welche auf den Außenwänden der Halle aufliegen und durch die Decke durchstoßen. Zwischen den Trägern wird mit 16cm Stahlträgern die sekundäre Tragstruktur gebildet, auf welcher ein 16cm starkes Trapezblech angebracht ist. Auf dem Trapezblech befindet sich eine 20cm starke Dämmschicht, die Dampfsperre und schließlich die Kiesschicht. </span></p><p style="text-align:left;margin-bottom:14pt;line-height:14pt;"><span style="font-family:Arial;font-size:10pt;">Der Deckendurchbruch der zwölf Oberlichtbänder ist identisch und beträgt im Innendurchmesser je 8,035m x 1,5m. Der Aufsetzkranz hat eine Breite von 10cm. Von innen sorgt eine weiße Abdeckung zwischen Oberlichtband und abgehängter Decke für eine klare Optik des Lichtschachts. Diese Abdeckung wird bei der lichten Breite des Oberlichtes nicht berücksichtigt.</span></p><p style="text-align:left;line-height:14pt;"><span style="font-family:Arial;font-size:10pt;font-style:italic;">Dachfläche über Foyer</span></p><p style="text-align:left;margin-bottom:14pt;line-height:14pt;"><span style="font-family:Arial;font-size:10pt;">Der Dachaufbau über dem Foyer besteht aus 36cm dicken Holzbalken, auf denen ein 14cm starkes Trapezblech direkt aufgebracht ist. Auf dem Trapezblech liegt eine 20cm dicke Dämmung, darüber befindet sich die Dampfsperre. Die oberste Schicht bildet das Substrat zur Begrünung.</span></p><p style="text-align:left;margin-bottom:14pt;line-height:14pt;"><span style="font-family:Arial;font-size:10pt;">Der Deckendurchbruch des Oberlichtbands hat einen Innendurchmesser von 19,51m x 1,20m. Der Aufsetzkranz hat eine Breite von 10cm. Hier sorgt eine weiße Verputzung zwischen Oberlichtband und abgehängter Decke für eine klare Optik des Lichtschachts. Die Verputzung wird bei der lichten Breite des Oberlichtes nicht berücksichtigt.</span></p><p style="text-align:left;line-height:14pt;"><span style="font-family:Arial;font-size:10pt;text-decoration:underline;">Dachentwässerung</span></p><p style="text-align:left;margin-bottom:14pt;line-height:14pt;"><span style="font-family:Arial;font-size:10pt;">Die bestehende Entwässerung der Flachdächer wird durch eine Sanierung der Oberlichtbänder nicht beeinflusst und muss daher nicht verändert werden. </span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;font-weight:bold;">4.  Baustelle</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Die Baumaßnahmen finden größtenteils in den Sommerferien statt. </span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Nach Erfordernis und Absprache finden die Bauarbeiten teilweise während des laufenden Hallenbetriebs statt. Die sich durch den laufenden Hallenbetrieb ergebenden Beeinträchtigungen für kontinuierliche Arbeitsabläufe sind vom Auftragnehmer organisatorisch im Arbeitsablauf zu berücksichtigen:</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;font-weight:bold;">nichtstörende Tätigkeiten während des Schulbetriebs ganztags, störende wie Bohrarbeiten in Beton, lärmverursachender Maschinen- und Gerätebetrieb und dergleichen außerhalb des hauptsächlichen Schulbetriebs nachmittags ab 13:00 Uhr.</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Störende Tätigkeiten sind zwingend der Bauleitung vorab anzuzeigen und genehmigen zu lassen.</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Die Arbeiten insgesamt müssen lärmarm erfolgen; lautes Rufen, das Abspielen von Unterhaltungsmedien und dergleichen sind zu unterlassen.</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Außerdem ist während des laufenden Schulbetriebs der insbesondere in den Pausen erhebliche Schülerverkehr innerhalb und außerhalb des Gebäudes zu berück- sichtigen. Gefahrenbereiche sind entsprechend zu kennzeichnen und abzusperren. Auch während der Ferien ist das Schulgelände für die Öffentlichkeit geöffnet und es ist mit Personenverkehr zu rechnen.</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-size:10pt;font-family:Arial;">Personen dürfen sich auf keinen Fall unter schwebenden Lasten aufhalten können. </span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Auf dem Schulgelände gilt die Straßenverkehrsordnung. Auf der Gebäudezufahrt ist Schrittgeschwindigkeit einzuhalten. Gegenüber dem Schüler- und Personenverkehr besteht eine besondere Sorgfalts- und Rücksichtnahmepflicht. Mit unerwartetem und unvorsichtigem Verhalten der Schüler ist jederzeit und überall zu rechnen. Rückwärtsfahren ist nur in Ausnahmefällen erlaubt, hierbei besteht Einweisungspflicht. Einweisungspflicht besteht generell beim Fahren mit Großfahrzeugen auf dem Schulgelände.</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Zufahrtswege für Feuerwehr-, Rettungs-, Polizei- und sonstige Hilfsfahrzeuge außerhalb des Gebäudes ebenso wie Rettungswege und Notausgänge im Gebäude sind jederzeit freizuhalten.</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Zugänglichkeit zum Gebäude besteht in den Schulferien montags bis freitags von 07:00 bis 16:00 Uhr. Beabsichtigte bzw. erforderliche Arbeitszeiten darüber hinaus sind mit dem Auftraggeber und Hausmeistern mit ausreichendem Vorlauf von mindestens 3 Tagen abzusprechen.</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Material ist zwingend nur in Absprache mit der Bauleitung auf der Baustelleneinrichtungsfläche zu lagern. Firmenfahrzeuge sind nach Be- und Entladevorgängen auf dem allgemeinen Parkplatz abzustellen. Materialanlieferungen können über den Parkplatz Sportlereingang erfolgen. Eine Ladezone wird in Absprache mit dem Auftraggeber und der Bauleitung festgelegt.</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Die Unterrichts- und Pausenzeiten sind wie folgt:</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">1.Std. 		7:40 - 8:25 Uhr</span><br/><span style="font-family:Arial;font-size:10pt;">2. Std.		8:30 - 9:15 Uhr</span><br/><span style="font-family:Arial;font-size:10pt;">	Pause</span><br/><span style="font-family:Arial;font-size:10pt;">3. Std.		9:35 - 10:20 Uhr</span><br/><span style="font-family:Arial;font-size:10pt;">4. Std.		10:25 - 11:10 Uhr</span><br/><span style="font-family:Arial;font-size:10pt;">	Pause</span><br/><span style="font-family:Arial;font-size:10pt;">5.Std.		11:25 - 12:10 Uhr</span><br/><span style="font-family:Arial;font-size:10pt;">6. Std.		12:15 - 13:00 Uhr</span><br/><span style="font-family:Arial;font-size:10pt;">	Mittagspause</span><br/><span style="font-family:Arial;font-size:10pt;">7. Std.		13:30 - 14:15 Uhr</span><br/><span style="font-family:Arial;font-size:10pt;">8. Std.		14:20 - 15:05 Uhr</span><br/><span style="font-family:Arial;font-size:10pt;">	Pause</span><br/><span style="font-family:Arial;font-size:10pt;">9. Std. 		15:15 - 16:00 Uhr</span><br/><span style="font-family:Arial;font-size:10pt;">10. Std. 	16:05 - 16:50 Uhr</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Über Straßensperrungen und ähnliches in den Zufahrtsbereichen im Ausführungszeitraum ist zum Zeitpunkt der Veröffentlichung der Ausschreibung nichts bekannt, dies kann jedoch während der Ausführung nicht gänzlich ausgeschlossen werden.</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Materiallieferungen und -sendungen sind nicht an den Auftraggeber, die Schule oder die Bauleitung zu richten, sondern an einen ortsanwesenden Beauftragten des Auftragnehmers. Seitens des Auftraggebers, der Schule bzw. der Bauleitung werden keinerlei Materiallieferungen angenommen oder quittiert oder Fracht- und Transportgebühren verauslagt. </span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Abschließbare Aufenthalts- und Lagerräume stehen nicht zur Verfügung. Die Baustelleneinrichtungsfläche wird vor dem Gebäude eingerichtet. Lagerplätze können nur innerhalb der Baustelleneinrichtungsfläche nach vorheriger Absprache mit der Bauleitung eingerichtet werden. Hilfskräfte und Transporthilfen stehen bauseits nicht zur Verfügung. Der Auftragnehmer hat die für ihn angelieferten Materialien sicher zu lagern. Die benutzten Flächen sind nach der Räumung in ihren ursprünglichen Zustand zu versetzen.</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Durch die Ausführung seiner Arbeiten oder durch den Transport entstandene Schäden an Gebäuden, Straßen, Zufahrten, Außenanlagen, Versorgungsleitungen, Kanälen usw. hat der Auftragnehmer auf seine Kosten sofort zu beheben. Die Behebung ist von ihm selbst zu veranlassen.</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Abtrennungen des Baubereichs wie Staubschutzwände oder Absperrungen sind stets geschlossen zu halten, um das Verbreiten von Verschmutzungen im übrigen Gebäude und das Betreten der Baubereiche durch Unbefugte zu verhindern.</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Anschlussleitungen für Baustrom und Bauwasser zu den Entnahmestellen sind so zu verlegen, dass sie keine Unfallgefährdung oder Behinderung darstellen.</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Hofeinläufe dürfen nicht zur Abwasser- oder Schmutzbeseitigung (Mörtel, Farbe etc.) genutzt werden. Abwasser muss ordnungsgemäß eingeleitet werden und darf keine Verunreinigungen aufweisen, die den einschlägigen und örtlichen Entwässerungsvorschriften widersprechen.</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Verschmutzungen, Bauabfälle und dergleichen sind unverzüglich (täglich) zu beseitigen. Kosten, die dem Auftraggeber für die Beseitigung der Verschmutzungen entstehen, werden dem Auftragnehmer in Rechnung gestellt und von dessen Rechnung abgezogen.</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;font-weight:bold;">5.  Arbeits- und Gesundheitsschutz</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Der Auftragnehmer ist hinsichtlich des Arbeits- und Gesundheitsschutzes über die Erfüllung der Arbeitsschutzpflichten gegenüber seinen Beschäftigten und sich selbst sowie zur Abstimmung mit anderen Unternehmern entsprechend § 8 ArbSchG und § 6 Abs. 2 UVV bdquo;Grundsätze der Präventionldquo; (BGV A 1) hinaus auch zur Beachtung und Abstellung möglicher Gefährdungen Dritter (Schulbetrieb) verpflichtet. Stellt der Auftragnehmer oder seine Beschäftigten Mängel oder Gefahrensituationen fest, sind diese unverzüglich den Vorgesetzten, gegebenenfalls anderen Firmen und in jedem Fall der Bauleitung zu melden und es ist auf deren Abstellung hinzuwirken.</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">Die für die Durchführung der Leistungen des Auftragnehmers gemäß den Unfallverhütungsvorschriften und den Vorschriften der Bau- und Berufsgenossenschaft erforderlichen Schutzausrüstungen im Allgemeinen sowie die persönliche Schutzausrüstung für die Arbeitnehmer im Speziellen sind unentgeltlich zur Verfügung zu stellen.</span></p><p style="text-align:left;margin-bottom:8pt;line-height:108%;"><span style="font-family:Arial;font-size:10pt;">In diesem Zusammenhang wird ausdrücklich auf die Einhaltung der einschlägigen arbeitssicherheitstechnischen Vorschriften hingewiesen. Der Auftragnehmer ist zur deren Einhaltung verpflichtet. Die Beauftragung eines Sicherheits- und Gesundheitsschutz-Koordinators durch den Auftraggeber entbindet den Auftragnehmer hiervon nicht.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Toiletten- und Waschräume werden dem Auftragnehmer innerhalb der Baustelleneinrichtungsfläche in Form einer Mobiltoilette von der Bauherrschaft zur Verfügung gestellt.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Vorbemerkungen zur Leistungsbeschreibung</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Remark><BoQCtgy ID="id3" RNoPart="00"><LblTx><p><span>Planung und Dokumentation</span></p></LblTx><BoQBody><Itemlist><Item ID="id4" RNoPart="1"><Qty>1.000</Qty><QU>psch</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Anfertigung der Werk- und Montageplanung</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">einschließlich Aufmaß der Oberlichter vor Ort.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Anfertigung der Werk- und Montageplanung</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id5" RNoPart="2"><Qty>1.000</Qty><QU>psch</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Durchführung der vollständigen Prüfung und des Funktionstests der NRA-Anlage nach Errichtung bzw. vor Inbetriebnahme. </span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Funktionsprobe NRA-Anlage</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id6" RNoPart="3"><Qty>1.000</Qty><QU>psch</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Erstellen von Revisionsunterlagen aller gelieferten sicherheitsrelevanten Bauteile.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Dokumentation</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id7" RNoPart="4"><Qty>1.000</Qty><QU>psch</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Abnahme der RWA-Anlagen in Oberlichtbändern durch qualifiziertes Fachpersonal gemäß den geltenden Vorschriften.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Kontrolle der Öffnungselemente sowie die vollständige Dokumentation der Abnahme in einem Prüf-/ Abnahmeprotokoll.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Anfahrt und erforderliche Nebenleistungen sind im Einheitspreis enthalten.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Abnahme RWA-Anlagen</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item></Itemlist></BoQBody></BoQCtgy><BoQCtgy ID="id8" RNoPart="01"><LblTx><p><span>Baustelleneinrichtung</span></p></LblTx><BoQBody><Itemlist><Item ID="id9" RNoPart="1"><Qty>1.000</Qty><QU>psch</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Baustelleneinrichtung für sämtliche aufgeführten Leistungen, sowie notwendige Gerätschaften, Werkzeuge und Hilfsmittel. </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Baustelleneinrichtung in Abstimmung und Koordination mit dem Bauherrn oder dessen Vertreter, auf dem Grundstück des Auftraggebers.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Bei der Lagerung von Material, Arbeitsmitteln und Geräten außerhalb des Gebäudes sind fortwährend Schutzmaßnahmen erforderlich. Hierbei ist besonders  Publikumsverkehr - auch Kinder - auf dem Grundstück zu berücksichtigen. </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Verkehrssicherungsmaßnahmen sowie die spätere Säuberung von Zugangs- und Verkehrswegen ist mit dieser Position abgegolten. Komplette Baustelleneinrichtung zu Beginn einrichten, Vorhalten für den Zeitraum der Baumaßnahme und vollständige Räumung nach Fertigstellung der Arbeiten.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Baustelleneinrichtung</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id10" RNoPart="2"><Qty>1.000</Qty><QU>psch</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Einsatz eines Mobilkrans inkl. Bedienpersonal zur Durchführung von Hub- und Transportarbeiten für Baustoffe auf der Baustelle.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">An- und Abfahrt des Mobilkrans zur Baustelle</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Auf- und Abbau des Krans inkl. erforderlicher Abstützungen</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Gestellung eines geprüften Kranführers</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Durchführung sämtlicher erforderlicher Hubarbeiten</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Bereitstellung der notwendigen Anschlagmittel (z. B. Rundschlingen, Seile, Ketten)</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Einhaltung aller sicherheitsrelevanten Vorschriften (DGUV, Betriebssicherheitsverordnung etc.)</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Hakenhöhe: 15m</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Ausladung 20m</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Traglast 2t</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Mobilkran</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id11" RNoPart="3"><Qty>1.000</Qty><QU>psch</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Personenauffangnetze montieren und demontieren</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">mit Einlage von Staubschutzgewirk (Monofilgarn, 50g/m², luft- und wasserdurchlässig)</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">nach EN 1263-1 und -2</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">und DGUV Regel 101-011</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">12 Leistungsbereiche je 8,00 lfm</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">insgesamt 96lfm</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Lichte Höhe der Sporthalle: ca. 7,00 m.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Der Sportboden ist bei der Montage zu schützen. Die Kassettendecke darf nicht beschädigt werden.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Personenauffangnetze montieren und demontieren</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id12" RNoPart="4"><Qty>1.000</Qty><QU>psch</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Unterhalb des Oberlichtes im Foyer ist zur Absturzsicherung ein Gerüst zu errichten.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Das Gerüst ist so zu errichten, dass eine maximale Fallhöhe von 1m bei Sturz durch das Oberlicht nicht überschritten wird. Das Gerüst darf daher nicht breiter als ca 1,10m sein. (Sollte nicht klar sein, ob das Gerüst passt, so ist dies vorher mit dem Bauherren zu klären.)</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Es ist die DGUV Information 201-011 zu beachten</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Dabei ist zu beachten, dass unter dem Gerüst Rettungswege freizuhalten sind.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Lichte Höhe des Foyers ca. 3,50 m</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Innengerüst als Absturzsicherung Foyer</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item></Itemlist></BoQBody></BoQCtgy><BoQCtgy ID="id13" RNoPart="02"><LblTx><p><span>Demontagearbeiten</span></p></LblTx><BoQBody><Itemlist><Item ID="id14" RNoPart="1"><Qty>12.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Demontage und vom Dach transportieren der bestehenden</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Lichtbandkonstruktion, bis auf Zarge. </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Zarge bleibt bestehen.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Die Lichtbänder sind bei Bedarf in handhabbare Einzelteile zu zerlegen.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Maße Bestandslichtbänder</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">1,70m x 8,25m</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Abbruch Lichtbänder Halle</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id15" RNoPart="2"><Qty>1.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Demontage und vom Dach transportieren der bestehenden</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Lichtbandkonstruktion, bis auf Zarge. </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Zarge bleibt bestehen.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Das Lichtband ist bei Bedarf in handhabbare Einzelteile zu zerlegen.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Maße Bestandslichtband</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">1,40m x 19,75m</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Abbruch Lichtband Foyer</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id16" RNoPart="3"><Qty>1.000</Qty><QU>psch</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Abtransport und fachgerechte Entsorgung des demontierten Materials der vorgenannten Positionen einschließlich Bereitstellung eines geeigneten Behälters für den Abtransport. </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Die Entsorgung erfolgt gemäß den geltenden gesetzlichen Vorschriften. Ein entsprechender Entsorgungsnachweis ist vorzulegen.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Entsorgung Bestandslichtbänder</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item></Itemlist></BoQBody></BoQCtgy><BoQCtgy ID="id17" RNoPart="03"><LblTx><p><span>Oberlichter Sporthalle</span></p></LblTx><BoQBody><Itemlist><Item ID="id18" RNoPart="1"><Qty>12.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Aufstockzarge H = 400mm</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">umlaufend voll aufliegend</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">bandbeschichtet, werkseitig aufgebracht, ähnlich RAL 9002</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Stahlblechdicke: bis zu 2,0mm, nach statischer Erfordernis, inkl. erforderlicher</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Verbindungselemente und Befestigungsmittel, verzinkt,</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Zargensteg senkrecht</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">angeordnet. Angepasst an bauseitige, bestehende Unterkonstruktion</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Aufstockzarge</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id19" RNoPart="2"><Qty>12.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Überhangkragen und Wärmedämmung als Zulage zur Aufstockzarge</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Überhangkragen bestehend aus mehrfach gekantetem, max. 1,5mm starken walzblankem Aluminium-Blech</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">auf dem Zargenkopf montiert</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">inkl. Stoßverbindungen und Eckausbildungen</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Zuschnitt nach Erfordernis zum Schutz des Zargenfußes</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Die Wärmedämmung besteht aus 80mm Mineralfaserdämmung A1</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Überhangkragen und Wärmedämmung</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id20" RNoPart="3"><Qty>12.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">Oberlichtbänder Klassisches Tageslichtsystem als gewölbtes Dachoberlichtband konzipiert zur</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">Erfüllung zeitgemäßer Anforderungen im Gewerbebau.</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">Allgemeine bauaufsichtliche Zulassung</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- U-Wert-Ermittlung gemäß EN ISO 10077 2:2012</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Ut horizontal (Verglasung): 1,3 W/m²K</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Ut vertikal (Verglasung): 1,2 W/m²K</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Ur (Lichtband): 1,4 W/m²K</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Urc (Lichtband + Aufsatzkranz):1,3 W/m²K</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Verglasung zweischalig</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- außen 16 mm PC-Stegplatte opal</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- innen 10 mm PC-Stegplatte klar</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- T D65 (Lichttransmissionsgrad): 31 %</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- g (Gesamtenergiedurchlaßgrad): 31 %</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">Baustoffklasse / Brandverhalten: </span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Brandüberschlagschutz nach DIN 18234 Teil 4 Weiche Bedachung,</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">-schwerentflammbar nach DIN 4102</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">-nicht brennend abtropfend</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">Schalldämmmaß </span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Rw: Schallschutz gemäß Prüfinstitut</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- SG-Bauakustik: Rw = 25 dB</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Windstaudruck q: bis 0,8 KN/m² für geschlossene</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">Gebäude</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">Lichte Öffnung: </span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Länge: bis 8,50 m</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Breite: bis 1,80 m </span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Oberlichtbänder</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id21" RNoPart="4"><Qty>12.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Hagel- und Durchsturzschutzgitter</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Hochstabiles korrosionsbeständiges Feinstahlgeflecht, mit einer Rasterung für optimale Lichttransmission, im Abstand von ca. 40 mm über der Verglasung montiert.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Hagelsicherheit:</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Hagelwiderstandsklassifizierung der Verglasung nach Schweizer Prüfvorgaben</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">VKF Bern für höchste Hagelwiderstandsklasse HW5 (Prüfzeugnis Nr. 173-</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">09/9c)</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Lichtdurchlässigkeit HW5</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Mechanik (Befestigung) HW5</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Hagelschutzwirkung (Wasserdichtigkeit)HW5</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Aussehen (unbeschädigte PC-Schale) HW5</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Durchsturzsicherheit:</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Gemäß dynamischem Belastungsversuch für Kunststoff-Verglasungen (50 kg</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">aus 2,40 m Höhe) werden folgende Klassifizierungen erreicht:</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- GS-Bau-18: durchsturzsicheres Bauteil</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- DIN EN 14963: Stoßbeanspruchung großer weicher Körper (SB 1200)</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Hagel- und Durchsturzschutzgitter</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id22" RNoPart="5"><Qty>12.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">RWA-Anlage</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">natürliches pneumatisches Rauch- und Wärmeabzugsgerät NRWG</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">NG: 1,10 x 2,30m Aa=1,64m² Ageo=2,30m²</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">Technischer Leistungsnachweis:</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- CE-Zertifikat</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Windlast: WL 1500 N/m2</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Schneelast: SL 500 N/m2</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Temperaturklasse: -05</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- B: 300 E</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- RE: 1000</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Auslösetemperatur: 68°C</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Öffnungswinkel: 155°</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>RWA-Anlage</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id23" RNoPart="6"><Qty>12.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Zulage für Sondertraverse Sonderanfertigung für bauseitiges Öffnungsmaß der RWA-Anlage</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Die Sondertraverse ist so auszuführen, dass sie die dauerhaft sichere Funktion der RWA-Anlage gewährleistet.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Zulage für Sondertraverse</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id24" RNoPart="7"><Qty>12.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Elektrischer Öffner 230V als Lüftungs-Zulage zur NRA-Klappe</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Hub 300mm</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">230V-Motoröffner für natürliche Lüftung, zum stufenlosen Öffnen und Schließen von Lichtbandklappen</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Technische Daten Spindelantrieb:</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Nennspannung: 230 V</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Nennstrom: 0,6 A</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Frequenz: 50 Hz</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Hubhöhe: 300 mm, stufenlos</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Hubkraft: 500 N</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Schutzart: IP 54</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Inkl. Anschlusskabel</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Gehäuse: RAL 9002 grauweiß</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Lastabschaltung integriert</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Inklusive erforderliche Verbindungsmitte</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Bauseitiger Elekttoanschluss und Verkabelung</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Elektrischer Öffner 230V</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id25" RNoPart="8"><Qty>12.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Hagel- und Durchsturzgitter für RWA an Lichtbandklappe</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Für dauerhafte Hagel- und Durchsturzsicherheit. Hochstabiles</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">korrosionsbeständiges Feinstahlgeflecht, mit einer Rasterung für optimale</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Lichttransmission, im Abstand von ca. 40 mm über der Verglasung montiert.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Hagelsicherheit:</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Hagelwiderstandsklassifizierung der Verglasung nach Schweizer Prüfvorgaben</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">VKF Bern für höchste Hagelwiderstandsklasse HW5 (Prüfzeugnis Nr. 173-</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">09/9c)</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Lichtdurchlässigkeit HW5</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Mechanik (Befestigung) HW5</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Hagelschutzwirkung (Wasserdichtigkeit)HW5</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Aussehen (unbeschädigte PC-Schale) HW5</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Durchsturzsicherheit:</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Gemäß dynamischem Belastungsversuch für Kunststoff-Verglasungen (50 kg</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">aus 2,40 m Höhe) werden folgende Klassifizierungen erreicht:</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- GS-Bau-18: durchsturzsicheres Bauteil</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- DIN EN 14963: Stoßbeanspruchung großer weicher Körper (SB 1200)</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- SUVA (Schweiz): Nachweis durchbruchsicheres Bauteil</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Hagel- und Durchsturzgitter für RWA</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id26" RNoPart="9"><Qty>12.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Innenliegende Durchsturzsicherung für RWA</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Hochstabiles korrosionsbeständiges Gitterelement</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Gemäß dynamischem Belastungsversuch (50kg aus 2,40m Höhe = 1200 J) werden folgende Klassifizierungen gefordert:</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- GS-Bau-18: durchsturzsicheres Bauteil</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- DIN EN 14963 / ETAG 010: Schlagfestigkeit</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">weicher Stoß (SB 1200)</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Innenliegende Durchsturzsicherung für RWA</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id27" RNoPart="10"><Qty>12.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Bestehende Rohrleitung der RWA-Klappen an neue RWA-Klappen anschließen.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Rohrleitung fachgerecht verlängern und inklusive erforderlicher Verbindungsmittel anpassen. Ausführung gemäß den Anforderungen der RWA-Anlagen, sodass das Auslösegas vom Handauslöser zuverlässig zu den Öffnungselementen geleitet wird und diese im Brandfall sicher öffnen.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Abschluss vor Funktionsprobe der Gesamtanlage.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Anschluss Rohrleitungssystem an RWA</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id28" RNoPart="11"><Qty>1.000</Qty><QU>psch</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Wind- und Regenschließautomatik für ein sicheres Schließen der Lüftungsklappe bei Niederschlag, Schneefall, starkem Nebel und hoher Windgeschwindigkeit, bestehend aus</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">einem AP-Schalt- und Steuerungskasten, sowie einer beheizten Regenfühlerplatte und einer elektronischen Windmesseinrichtung.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Elektroanschluss und Verkabelung erfolgen bauseits.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Wind- und Regenschließautomatik</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item></Itemlist></BoQBody></BoQCtgy><BoQCtgy ID="id29" RNoPart="04"><LblTx><p><span>Oberlicht Foyer</span></p></LblTx><BoQBody><Itemlist><Item ID="id30" RNoPart="1"><Qty>1.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Aufstockzarge H = 40mm</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">umlaufend voll aufliegend, Stahlblech,</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">bandbeschichtet, werkseitig aufgebracht, ähnlich RAL 9002</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Stahlblechdicke: bis zu 2,0mm, nach statischer Erfordernis, inkl. erforderlicher</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Verbindungselemente und Befestigungsmittel, verzinkt,</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Zargensteg senkrecht</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">angeordnet. Angepasst an bauseitige bestehende Unterkonstruktion</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Aufstockzarge</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id31" RNoPart="2"><Qty>1.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Überhangkragen und Wärmedämmung als Zulage zur Aufstockzarge</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Überhangkragen bestehend aus mehrfach gekantetem, max. 1,5mm starken walzblankem Aluminium-Blech</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">auf dem Zargenkopf montiert</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">inkl. Stoßverbindungen und Eckausbildungen</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Zuschnitt nach Erfordernis zum Schutz des Zargenfußes</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Die Wärmedämmung besteht aus 80mm Mineralfaserdämmung A1</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Überhangkragen und Wärmedämmung</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id32" RNoPart="3"><Qty>1.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">Oberlichtband Klassisches Tageslichtsystem als gewölbtes Dachoberlichtband konzipiert zur</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">Erfüllung zeitgemäßer Anforderungen im Gewerbebau.</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">Allgemeine bauaufsichtliche Zulassung</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- U-Wert-Ermittlung gemäß EN ISO 10077 2:2012</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Ut horizontal (Verglasung): 1,3 W/m²K</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Ut vertikal (Verglasung): 1,2 W/m²K</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Ur (Lichtband): 1,4 W/m²K</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Urc (Lichtband + Aufsatzkranz):1,3 W/m²K</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Verglasung zweischalig</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- außen 16 mm PC-Stegplatte opal</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- innen 10 mm PC-Stegplatte klar</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- T D65 (Lichttransmissionsgrad): 31 %</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- g (Gesamtenergiedurchlaßgrad): 31 %</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">Baustoffklasse / Brandverhalten: </span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Brandüberschlagschutz nach DIN 18234 Teil 4 Weiche Bedachung,</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">-schwerentflammbar nach DIN 4102</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">-nicht brennend abtropfend</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">Schalldämmmaß </span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Rw: Schallschutz gemäß Prüfinstitut</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- SG-Bauakustik: Rw = 25 dB</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Windstaudruck q: bis 0,8 KN/m² für geschlossene</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">Gebäude</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">Lichte Öffnung: </span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Länge: bis 20,00 m</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Breite: bis 1,40 m</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Oberlichtband</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id33" RNoPart="4"><Qty>1.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Hagel- und Durchsturzgitter</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Hochstabiles korrosionsbeständiges Feinstahlgeflecht, mit einer Rasterung für optimale Lichttransmission, im Abstand von ca. 40 mm über der Verglasung montiert.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Hagelsicherheit:</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Hagelwiderstandsklassifizierung der Verglasung nach Schweizer Prüfvorgaben</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">VKF Bern für höchste Hagelwiderstandsklasse HW5 (Prüfzeugnis Nr. 173-</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">09/9c)</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Lichtdurchlässigkeit HW5</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Mechanik (Befestigung) HW5</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Hagelschutzwirkung (Wasserdichtigkeit)HW5</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Aussehen (unbeschädigte PC-Schale) HW5</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Durchsturzsicherheit:</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Gemäß dynamischem Belastungsversuch für Kunststoff-Verglasungen (50 kg</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">aus 2,40 m Höhe) werden folgende Klassifizierungen erreicht:</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- GS-Bau-18: durchsturzsicheres Bauteil</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- DIN EN 14963: Stoßbeanspruchung großer weicher Körper (SB 1200)</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Hagel- und Durchsturzgitter</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id34" RNoPart="5"><Qty>3.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">RWA-Anlage</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Natürliches pneumatisches Rauch- und Wärmeabzugsgerät NRWG</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">NG: 1,10 x 2,30m Aa=1,64m² Ageo=2,30m²</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">Technischer Leistungsnachweis:</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- CE-Zertifikat</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Windlast: WL 1500 N/m2</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Schneelast: SL 500 N/m2</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Temperaturklasse: -05</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- B: 300 E</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- RE: 1000</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Auslösetemperatur: 68°C</span></p><p style="text-align:left;"><span style="font-family:Arial;font-size:10pt;">- Öffnungswinkel: 155°</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>RWA-Anlage</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id35" RNoPart="6"><Qty>3.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Zulage für Sondertraverse Sonderanfertigung für bauseitiges Öffnungsmaß der RWA-Anlage</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Die Sondertraverse ist so auszuführen, dass sie die dauerhaft sichere Funktion der RWA-Anlage gewährleistet.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Zulage für Sondertraverse</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id36" RNoPart="7"><Qty>3.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Elektrischer Öffner 230V als Lüftungs-Zulage zur NRA-Klappe</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Hub 300mm</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">230V-Motoröffner für natürliche Lüftung, zum stufenlosen Öffnen und Schließen von Lichtbandklappen</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Technische Daten Spindelantrieb:</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Nennspannung: 230 V</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Nennstrom: 0,6 A</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Frequenz: 50 Hz</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Hubhöhe: 300 mm, stufenlos</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Hubkraft: 500 N</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Schutzart: IP 54</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Inkl. Anschlusskabel</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Gehäuse: RAL 9002 grauweiß</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Lastabschaltung integriert</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Inklusive erforderliche Verbindungsmitte</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Bauseitiger Elekttoanschluss und Verkabelung</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Elektrischer Öffner 230V</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id37" RNoPart="8"><Qty>3.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Hagel- und Durchsturzgitter für RWA an Lichtbandklappe</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Für dauerhafte Hagel- und Durchsturzsicherheit. Hochstabiles</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">korrosionsbeständiges Feinstahlgeflecht, mit einer Rasterung für optimale</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Lichttransmission, im Abstand von ca. 40 mm über der Verglasung montiert.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Hagelsicherheit:</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Hagelwiderstandsklassifizierung der Verglasung nach Schweizer Prüfvorgaben</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">VKF Bern für höchste Hagelwiderstandsklasse HW5 (Prüfzeugnis Nr. 173-</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">09/9c)</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Lichtdurchlässigkeit HW5</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Mechanik (Befestigung) HW5</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Hagelschutzwirkung (Wasserdichtigkeit)HW5</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- Aussehen (unbeschädigte PC-Schale) HW5</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Durchsturzsicherheit:</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Gemäß dynamischem Belastungsversuch für Kunststoff-Verglasungen (50 kg</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">aus 2,40 m Höhe) werden folgende Klassifizierungen erreicht:</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- GS-Bau-18: durchsturzsicheres Bauteil</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- DIN EN 14963: Stoßbeanspruchung großer weicher Körper (SB 1200)</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- SUVA (Schweiz): Nachweis durchbruchsicheres Bauteil</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Hagel- und Durchsturzgitter für RWA</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id38" RNoPart="9"><Qty>3.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Innenliegende Durchsturzsicherung für RWA</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Hochstabiles korrosionsbeständiges Gitterelement</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Gemäß dynamischem Belastungsversuch (50kg aus 2,40m Höhe = 1200 J) werden folgende Klassifizierungen gefordert:</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- GS-Bau-18: durchsturzsicheres Bauteil</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">- DIN EN 14963 / ETAG 010: Schlagfestigkeit</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">weicher Stoß (SB 1200)</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Innenliegende Durchsturzsicherung für RWA</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id39" RNoPart="10"><Qty>3.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Bestehende Rohrleitung der RWA-Klappen an neue RWA-Klappen anschließen.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Rohrleitung fachgerecht verlängern und inklusive erforderlicher Verbindungsmittel anpassen. Ausführung gemäß den Anforderungen der RWA-Anlagen, sodass das Auslösegas vom Handauslöser zuverlässig zu den Öffnungselementen geleitet wird und diese im Brandfall sicher öffnen.</span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;"> </span></p><p style="width: 283pt;"><span style="font-family:Arial;font-size:10pt;">Abschluss vor Funktionsprobe der Gesamtanlage.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Anschluss Rohrleitungssystem an RWA</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item></Itemlist></BoQBody></BoQCtgy></BoQBody></BoQ></Award></GAEB>