<?xml version="1.0" encoding="UTF-8"?>
<!-- GXML Toolbox V3.3 R20200224;  http://www.gaeb-toolbox.de/  -->
<GAEB xmlns="http://www.gaeb.de/GAEB_DA_XML/DA83/3.2"><GAEBInfo><Version>3.2</Version><VersDate>2013-10</VersDate><Date>2026-01-26</Date><Time>14:29:06</Time><ProgSystem>/ GXML Toolbox V3.3 R20200224</ProgSystem><ProgName>ORCA AVA 23.2.1 - Professional Edition 23.02.01</ProgName></GAEBInfo><PrjInfo><NamePrj>9048</NamePrj><LblPrj>STF Sporthalle Theodor-Fontane-OS Potsdam</LblPrj><Cur>EUR</Cur><CurLbl>Euro</CurLbl></PrjInfo><Award><DP>83</DP><AwardInfo><Cat>SelectCall</Cat><Cur>EUR</Cur><CurLbl>Euro</CurLbl><SubmLoc/></AwardInfo><AddText><OutlineAddText><span>ZTV Estricharbeiten</span></OutlineAddText><DetailAddText><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">ZTV Estricharbeiten</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Für die Ausführung der Estricharbeiten gilt die DIN 18560 Estriche im Bauwesen und ihre Teile.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Vor Beginn der Arbeiten ist eine Nivellement vorzunehmen. Die Höhen sind von den bauseits vorgegebenen Höhenkennzeichnungen zu nehmen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Die Anordnung von erforderlichen Bewegungsfugen, ist dem Fugenplan zu entnehmen und mit der Bauleitung abzustimmen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Der Fugenplan ist auf Vollständigkeit und Eignung mit der zur Ausführung kommenden Estrichart abzustimmen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Estriche sind an aufgehenden Bauteilen mit einem  Randdämmstreifen zu versehen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Baustoffe:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Es dürfen nur trittfeste Wärmedämmstoffe (Kennzeichnung WD) verwendet werden. Der Nachweis über das Herstellungsdatum kann verlangt werden.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Es sind nur chromatarme Zemente zu verwenden.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Ausführung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Vor Beginn der Arbeiten sind die tatsächlichen Einbauhöhen gemeinsam mit der Bauleitung aufzunehmen und auch im Hinblick auf die Sturzhöhen zu überprüfen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Bereits fertiggestellte Leistungen Dritter, wie Sichtbetonbauteile, Installationen, Alufassade, Türen, Holzbauteilen, Sichtmauerwerk etc. sind vom Auftragnehmer wirksam gegen Beschädigung und Verschmutzung zu schützen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Der Herstellort des Estrich ist vor dem Gebäude.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Bei Materialtransport durch bauseits angebrachte Türen oder Fenster sind Vorkehrungen zu treffen, um Beschädigungen der Wände, Bekleidungen und Schwellen zuvermeiden. Die Art des Materialtransportes ist mit der Bauleitung abzusprechen. Zur Vermeidung von</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Verunreinigungen (Wasser, Schlämme) sind entsprechende Maßnahmen vorzusehen. Entstandene Verunreinigungen sind umgehend zu beseitigen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Böden mit verschiedenen Höhenkoten sind entsprechend abzuschalen, Türanschlagwinkel sind zu setzen, wobei immer der liegende Winkelschenkel vom höheren Estrichaufbau überdeckt wird. Aussparungen sind zu schalen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Trennschichten müssen eine glatte Oberfläche besitzen. Das Gefälle zu Einläufen ist in der Regel von 4 Seiten auszuführen. Die Estrichoberfläche ist grundsätzlich so auszuführen, dass Nutzbeläge üblicher Art, wie Beschichtungen,Linoleumbeläge, Fliesen etc. ohne weitere Egalisierungsmassnahmen aufgebracht werden.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">können. Somit sind Estrichoberkanten genau einzuhalten</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">und Schwindrisse zu vermeiden.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Vor Arbeiten, die Feinstaub erzeugen, sind die Räume entsprechend abzudichten, der Staub zu beseitigen und/ oder Absauggeräte zu verwenden. Die mit frisch ausgeführtem Estrich fertiggestellten Räume sind ohne Inanspruchnahme fremder Hilfe abzusperren, einschließlich des benötigten Absperrmaterials und, soweit erforderlich, gegen rasches, ungleichmäßiges Austrocknen zu schützen, insbesondere sind Vorkehrungen zum Schutz gegen Zugluft zu treffen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Die Estrichoberfläche muss nach Freigabe zur Begehbarkeit so widerstandsfähig sein, dass sie bis zur Verlegung des Oberbodens den normal üblichen Handwerkerverkehr ohne Schaden aufnehmen kann.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Dämmungen:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Auf die Rohdecke gestellte, selbstklebende Randstreifen sind stoßüberlappend so anzubringen, dass alle Bauteile wirksam getrennt sind und ein Überstand über OK-Estrich gewährleistet ist. Der Randstreifenüberstand darf vor dem Verlegen des Bodenbelages grundsätzlich nicht abgeschnitten werden. Er wird vom Bodenleger, Fliesenleger etc. belagbündig abgeschnitten, um zu gewährleisten, dass die Kontakttrennung im Randanschluss erhalten bleibt.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Ist die Wandbekleidung nicht bis zur Rohdecke geführt (&#x22;abgestellter Trockenbau&#x22;) und befindet sich der Absatz noch innerhalb des Fußbodenaufbaus, so müssen zur Vermeidung von Schallbrücken Dämmstoffstreifen als Auflage für die abgewinkelten Randstreifen eingebracht werden. Bei zweilagigen Dämmschichten ist der abgewinkelte Schenkel des Randstreifens auf die erste Dämmschichtlage zu stellen. Auch bei Rohr- und Kanaldurchführungen sind Randstreifen zu verlegen. Randdämmstreifen sind wie die Dämmung abzudecken.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Wird ein Schalldämmmaß ohne nähere Erläuterung im Leistungsverzeichnis angegeben, so genügt die Einhaltung des Labor-Dämmmaßes nicht. Der Auftragnehmer hat nach seinem vorauszusetzenden Wissensstand Bedenken geltend zu machen, wenn der effektiv gewollte oder nach Vorschrift erforderliche Wert mit der ausgeschriebenen Konstruktion vor Ort nicht erreicht wird.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Schalldämmung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Erkennbare Mängel am Baukörper sowie in den Vorleistungen, die sich nachteilig auf die Schalldämmung auswirken können (z.B. fehlende, zu niedrige Randdämmstreifen), sind dem Auftraggeber mitzuteilen. Metallteile wie Abläufe, Rohre, Standkonsolen, Trennschienen u. dgl. dürfen grundsätzlich keine starre Verbindung mit dem Estrich besitzen; sie sind mit Dämmstreifen zu ummanteln und ggf. gegen chemische Einflüsse aus dem Estrich zu schützen. Bei mehrlagigen Dämmschichten ist eine allseitige Fugenüberdeckung vorzunehmen. In der Regel ist die Dämmung unter Anschlagschienen durchzuführen. Dämmstoffe dürfen keinesfalls Hohlstellen im Fußboden ergeben. Falls die Rohdecke unzulässige Toleranzen aufweist, ist nach Rücksprache mit der Bauleitung ein Ausgleichsestrich aufzubringen. Dämmschichten sind an im Fußbodenaufbau befindliche Rohrleitungen kantengerade zu verlegen. Eine akustische Entkopplung ist zu garantieren. Insbesondere dürfen Rohrbefestigungen keinen Schall auf die Decken übertragen. Hohlräume zwischen und unterhalb von Rohren sind ggf. durch zusätzliche Schüttungen zu dämmen, bei späterem Fliesen- oder Plattenbelag ist ein gebundener Ausgleich erforderlich.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Die Verlegung der Trittschalldämmung ist (größtenteils) im Zuge der Herstellung der Fußbodenheizung durch das Sanitärgewerk vorgesehen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Trittschalldämmungen werden nur einlagig verlegt werden. Dämmschichten unter Estrichaufbau sind mit geeignetem Abdeckmaterial abzudecken. Die Verlegerichtung ist entgegengesetzt der Dämmschichtverlegung auszuführen. An den Stößen überlappt sich das Abdeckmaterial um mindestens 10 cm und ist an allen seitlichen, senkrechten Abschlüssen hochzuführen, sofern keine Randstreifen mit Folienlappen verwendet werden.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Fugen:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Vor dem Verlegen der Oberbeläge sind Fugen, die sich u. U. gebildet haben, fachgerecht mit Kunstharz zu verdübeln und auszugießen. Vorhandene Bewegungsfugen sind entsprechend zu berücksichtigen. Fugen sind nach einem Fugenplan anzulegen. Die Felder sollen nicht größer als 40 qm sein. Es sind auch Unterteilungen vorzunehmen, falls die Flächen vorspringen. Die einzelnen Felder sind ohne Arbeitsunterbrechung herzustellen. Fugen sind auch dort anzulegen, wo Körperschallübertragung vermieden werden soll. Ist bei schwimmenden Estrichen ein Höhenversatz der Fugen nicht auszuschließen, sind sie so zu verdübeln, dass eine Bewegung horizontal möglich ist. Scheinfugen sind mit entsprechenden Fugenprofilen auszuführen. Elastische Fugen sind grundsätzlich zu hinterfüllen, um eine Dreiflankenhaftung zu vermeiden.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;">Vor dem Einbau ist sich die Funktionsfähigkeit der FB-Heizung sowie die Abstimmung zum Heizprotokoll passend zum Abbinderbeschleuniger vom Heizungsbauer möglichst schriftlich bestätigen zu lassen. Messpunkte sind gemeinsam festzulegen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-weight:bold;font-family:Arial;">Ausführungszeitraum gemäß Bauterminplan in mehreren Bauabschnitten.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;"><span style="font-size:10pt;font-weight:bold;font-family:Arial;">Arbeitsunterbrechung durch die bauseitige Verlegung der Trittschallplatten- und Fußbodenheizung durch den Heizungsbauer ist einzukalkulieren.</span></p></DetailAddText></AddText><BoQ ID="id373"><BoQInfo><Name>15</Name><LblBoQ>Estricharbeiten</LblBoQ><OutlCompl>AllTxt</OutlCompl><BoQBkdn><Type>BoQLevel</Type><LblBoQBkdn>Titel</LblBoQBkdn><Length>2</Length><Num>Yes</Num></BoQBkdn><BoQBkdn><Type>BoQLevel</Type><LblBoQBkdn>Bereich</LblBoQBkdn><Length>2</Length><Num>Yes</Num></BoQBkdn><BoQBkdn><Type>Item</Type><Length>4</Length><Num>Yes</Num></BoQBkdn><BoQBkdn><Type>Index</Type><Length>1</Length><Num>No</Num></BoQBkdn><NoUPComps>4</NoUPComps><LblUPComp1 Type="Wages">Lohn</LblUPComp1><LblUPComp2 Type="Materials">Material</LblUPComp2><LblUPComp3 Type="Plant">Gerät</LblUPComp3><LblUPComp4 Type="Miscellaneous">Sonstiges</LblUPComp4><LblTime>Stunden</LblTime></BoQInfo><BoQBody><BoQCtgy ID="id1277" RNoPart="01"><LblTx><p><span>Vorbereitung</span></p></LblTx><BoQBody><Itemlist><Item ID="id1297" RNoPart="1"><Qty>1.000</Qty><QU>Psch</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Werkstattplanung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Erstellung von Estrichverlegeplänen, einschl. Fugenplan</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">und Abstimmung mit der Planung.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Die Verlegepläne sind rechtzeitig mit einem Vorlauf von</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">mindestens 4 Wochen vor Materialdisposition des AN</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">dem AG/Planer zur Prüfung zu übergeben.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">In den Zeichnungen sind Leistungen des AN und</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">bauseitig zu erbringenden Leistungen farblich</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">unterschiedlich darzustellen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Erstellung der erforderlichen Werkstattplanung und</span><span style="font-size:11pt;font-family:Arial;"> -details im für die Werkstatt- und Montagearbeiten notwendigen Umfang für alle angebotenen Leistungen, einschl. einem örtlichem Aufmaß inkl. Setzen der Höhenbezugspunkte</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Die durch den AN angefertigtre Planung</span><span style="font-size:11pt;font-family:Arial;"> ist dem AG und dessen OÜ zur Freigabe vorzulegen. </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Aufheizprotokoll des Estrichbeschleunigers zur Übergabe an Heizungsbau</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Die Materialbestellungen und Ausführung der Leistungen dürfen nur nach Freigabe erfolgen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Erstellen der Dokumentation</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Erstellen der Dokumentation (digital und 1x Papier) mit</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Fachunternehmererklärung </span><br/><span style="font-size:11pt;font-family:Arial;">Fachbauleitererklärung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Übereinstimmungserklärung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">schriftlicher Freimeldung zur Abnahme ggf vorhandener Mängel</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Prüfbescheinigungen / Dokumentation der Haftzugprüfung / CM-Messung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Fotos verdeckter Leistungen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Leistungsnachweis und Dokumentation aller verbauten Materialien</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Lieferscheine</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Produktdatenblätter</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Abrechnungshinweis: Diese Position wird 1x pauschal für</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">die Gesamtheit aller nachfolgenden Estrichpositionen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">gerechnet.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Abrechnung Freigabe OÜ Werkstattplanung 50%, Freigabe OÜ Dokumentation 50%</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:496pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Erstellung Werkstattplanung und Dokumentation</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id1278" RNoPart="2"><Qty>1.000</Qty><QU>Psch</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Einrichten und Räumen der Baustelle sowie Vorhalten der Baustelleneinrichtung für die Dauer der Arbeiten für sämtliche in der Leistungsbeschreibung aufgeführte Leistungen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Es werden auf der Baustelle 20 m² Estrichplatz in einer</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Entfernung von ca. 20 m zum Neubau bereitgestellt.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Diese Stelle ist im Rahmen der Bauanlaufbesprechung mit der Bauleitung abzustimmen. Der Mischplatz ist so einzurichten, dass ein Verwehen des Materials ausgeschlossen ist. Anlieferungen sind mit der Objektüberwachung vorher terminlich abzustimmen und es ist ein Mitarbeiter des AN zur Einweisung der Lieferanten vor Ort einzuplanen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Die Verteilung des zu verbauenden Materials im Gebäude</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">ist in alle Positionen einzukalkulieren.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Der Transport vom Mischplatz zum Einbauort ist Sache</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">des Unternehmers, alle Pumpen und Förderanlagen die zum Materialtransport nötig werden, der Schutz der eingebauten Fassaden und Durchgänge, die unfallfreie Verlegung und Fixierung des Pumpenschlauchs, die Beräumung und Schuttentsorgung sind mit in diese Position einzukalkulieren.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Der Auftragnehmer hat alle zusätzlichen Aufwendungen für den Transport seiner Materialien in die EPs einzukalkulieren</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Die Teilnahme an der Baubesprechung ist bis zur Fertigstellung der auszuführenden Leistung bindend. Zur Baubesprechung muss ein aussage- und entscheidungsbefähigter Vertreter teilnehmen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Einschl. herstellen und vorhalten der Abdeckung zum Schutz von Fenstern und Türen aus Glas vor mechanischen Beschädigungen einschl. deren späteren besenreine Beseitigung und Entsorgung.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Schutz- und Sicherheitsmaßnahmen nach den Unfallverhütungsvorschriften und den behördlichen Bestimmungen zur ordnungsgemäßen Durchführung der Baumaßnahmen sind einzuhalten.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Abrechnung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">50% nach Einrichtung, </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">50% nach besenreiner Beräumung einschl. der Schüttgüter.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Einrichten und Räumen der Baustelle,</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id1279" RNoPart="3"><Qty>1.000</Qty><QU>Psch</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Flächennivellement für alle Estrichflächen durchführen und Festhalten der Ergebnisse skizzenhaft in den Grundrissen zur Prüfung der geplanten Einbauhöhen (Bestand) sowie als Abrechnungsbasis, Raumweises Anzeichnen der Sollhöhen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Fläche rd 525 qm, 30 Räume</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:10pt;font-weight:bold;font-family:Arial;">Gemeinsame Durchführung mit Objektüberwachung</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Flächennivellement</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id1280" RNoPart="4"><Qty>521.000</Qty><QU>m²</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Reinigen des Untergrundes von groben Verunreinigungen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">wie Mörtel- oder Putzresten, durch gründliches Abfegen UND Absaugen, vorsichtiges Abstoßen von Unebenheiten, einschließlich Einsammeln und Beseitigen von Müll und Schutt.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Markierung von Beschädigungen in der Abdichtung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Die Abfälle sind in einen Schuttcontainer zu befördern.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Abrechnung Schuttcontainer gesondert.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Art des Untergrundes:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">- mit Bitumenbahn abgedichtete Stahlbetonplatten</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Vorbereiten des Untergrundes</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item></Itemlist></BoQBody></BoQCtgy><BoQCtgy ID="id1301" RNoPart="02"><LblTx><p><span>Unterbau</span></p></LblTx><BoQBody><Itemlist><Remark ID="id1302"><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Auf der Abdichtung der Bodenplatte werden Installationen wie Kabel und Leitungen verlegt. Diese sind mit einer gebundenen, druckstabilen Ausgleichsdämmung zu überdecken, die zum Teil im erforderlichen Gefälle zu den Abläufen zu führen ist und somit eine raumweise gleichbleibende Estrichstärke sicherstellt.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Ausgleichsschüttung</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Remark><Item ID="id1306" RNoPart="1"><Qty>27.200</Qty><QU>m³</QU><Description><CompleteText><ComplTSB>Yes</ComplTSB><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Liefern und einbauen einer schnelltrocknenden Wärmedämmung und Trittschalldämmung als Toleranzausgleich, als gebundene EPS-Schüttung mit recyceltem EPS (R)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Trockenrohdichte DMD = 110 kg/m³.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Bemessungswert Wärmeleitfähigkeit Lambda = 0,048 W/(mK)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Brandverhalten = E</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Mind. Einbaudicke = 35 mm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Trittschallverbesserung 25 dB</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Verkehrslast min. = 7 kN/m²</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">min. 35 mm dick eingebaut, verdichtet und eben abgezogen, inkl. aller Nebenleistungen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Inkl. hohlraumfreier Einbindung der bauseits verlegten Leitungen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Leitfabrikat: Thermowhite BEPS WD 100R o.glw.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"/></Text><TextComplement MarkLbl="11" Kind="Bidder"><ComplCaption><span style="font-size:11pt;font-family:Arial;">Angebotenes Fabrikat: </span></ComplCaption><ComplBody><span style="font-size:11pt;font-family:Arial;">&#x27;..........&#x27;</span></ComplBody><ComplTail><span style="font-size:11pt;font-family:Arial;"> </span><br/></ComplTail></TextComplement><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Bieterangabe</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Einbauhöhen im Mittel zwischen 45 und 60mm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Abrechnung nach cbm im eingebauten Zustand</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"/></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Gebundene Ausgleichsschüttung</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id1321" RNoPart="2"><Qty>53.000</Qty><QU>m²</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:10pt;font-weight:bold;font-family:Arial;">Zulage </span><span style="font-size:11pt;font-family:Arial;">Ausgleichsschüttung im Gefälle verlegen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Zulage zur </span><span style="font-size:11pt;font-family:Arial;">02.1</span><span style="font-size:11pt;font-family:Arial;"> für die Ausführung der Oberseite der Ausgleichsschüttung in einem geplanten Gefälle von 2-6%</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Die Anarbeitung an den bauseits eingebauten Bodenablauf / die Duschrinne ist Bestandteil der Leistung.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Abmessung von ca. 100 x 100 cm bis Duschraum 200 x 225 cm, </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">mit 6 Duschrinnen 180 x 10 cm und 6 Bodenabläufen in Duschen, Urinal, Technik</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Ausführung entsprechend Fliesenplänen bei Einzelduschen, Sammelduschen, Bodenabläufen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Abrechnung nach Quadratmeter schräger Oberseite</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Zulage Ausgleichsschüttung im Gefälle verlegen</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id16744" RNoPart="3"><Qty>25.000</Qty><QU>m</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Randschalung für zementgebundene Ausgleichsschüttung erstellen. </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Schüttungsstärke bis 60 mm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Liefern und fachgerecht einbauen inkl. aller Nebenarbeiten</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Zementgebundene Ausgleichsschüttung abstellen</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Remark ID="id1303"><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Die Trittschalldämmung und Fußbodenheizung wird bauseits durch den Heizungsbauer eingebracht, eine entsprechende Unterbrechung der eigenen Arbeiten ist einzukalkulieren.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Im Bereich der Flure der Sozialtrakte und Foyerzone ist die Ausührung nach Vorgabe Brandschutzkonzept mindestens schwerentflammbar Baustoffklasse B1 nach DIN 4102-1, Klasse zum Brandverhalten A2; B; d2 nach EN 13501-1 auszuführen </span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Dämmung</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Remark><Item ID="id1310" RNoPart="4"><Qty>521.000</Qty><QU>m²</QU><Description><CompleteText><ComplTSB>Yes</ComplTSB><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Wärmedämmschicht für Fußboden, EPS, WLG 035 DEO/WAB dh 150kPA, 80 mm als erste Lage</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Dämmschicht DIN 4108-10 als Unterlage für schwimmenden Heizestrich in Platten dicht gestoßen verlegen, Ausführung einschl. erforderlicher Zuschnitte und Anarbeitung an bauseitige Installationen auf/aus der Bodenplatte, Durchgänge, Stützen, Sockel, Fassadenelementen etc.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Verkehrslasten</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Flächenlasten: min bis 5 kN/m²,</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Dämmschichtdicke: 80mm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Anwendungsgebiet: DIN V 4108-10 DEO/WAB, hohe</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Druckbelastbarkeit - dh , </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Druckfestigkeit 150kPA</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">als Unterlage für Estrich.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Bemessungswert der Wärmeleitfähigkeit max. 0,035 W/mK</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Baustoffklasse nach DIN 4102 B1 schwer entflammbar</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Zulassung nach DIN EN 13163 mit CE-Kennzeichnung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"/></Text><TextComplement MarkLbl="11" Kind="Bidder"><ComplCaption><span style="font-size:11pt;font-family:Arial;">Angebotenes Fabrikat: </span></ComplCaption><ComplBody><span style="font-size:11pt;font-family:Arial;">&#x27;..........&#x27;</span></ComplBody><ComplTail><br/></ComplTail></TextComplement><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">(Bieterangabe für diese und die beiden Folgepositionen)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Einbauort: gesamtes Gebäude</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;text-decoration:underline ;font-family:Arial;">Wärmedämmschicht EPS 035 DEO/WAB dh 150kPA, 80 mm als erste Lage</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id1311" RNoPart="5"><Qty>92.000</Qty><QU>m²</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Wärmedämmschicht für Fußboden, EPS, WLG 035 DEO/WAB dh 150kPA, 60 mm als zweite Lage</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Dämmschicht DIN 4108-10 als Unterlage für schwimmenden Heizestrich in Platten dicht gestoßen  und stoßversetzt zur ersten Lage verlegen, Ausführung einschl. erforderlicher Zuschnitte und Anarbeitung an bauseitige Installationen auf/aus der Bodenplatte, Durchgänge, Stützen, Sockel, Fassadenelementen etc.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Verkehrslasten</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Flächenlasten: min bis 5 kN/m²,</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Dämmschichtdicke: 60mm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Anwendungsgebiet: DIN V 4108-10 DEO/WAB, hohe</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Druckbelastbarkeit - dh , </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Druckfestigkeit 150kPA</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">als Unterlage für Estrich.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Bemessungswert der Wärmeleitfähigkeit max. 0,035 W/mK</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Baustoffklasse nach DIN 4102 B1 schwer entflammbar</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Zulassung nach DIN EN 13163 mit CE-Kennzeichnung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Einbauort: FB-Aufbau 04 Technikbereiche, Lager, Heizung</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Wärmedämmschicht EPS 035 DEO/WAB dh 150kPA, 60 mm als zweite Lage</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id3807" RNoPart="6"><Qty>16.000</Qty><QU>m²</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Trittschalldämmschicht als Unterlage für Estrich aus Polystyrol-Hartschaum EPS DIN EN 13163,</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">- lotrechte Nutzlasten bis 5 kN/m²</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">- Lieferdicke 30-2mm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">- Stufe Zusammendrückbarkeit kleiner gleich 2 mm (CP 2) DIN V 4108-10,</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">- dynamische Steifigkeit SD 30 MN/m³</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">- Bemessungswert der Wärmeleitfähigkeit max. 0,038 W/mK DIN 4108-4</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">- geringe Zusammendrückbarkeit - sg, Anwendungsgebiet DIN V 4108-10 DES</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">- Baustoffklasse nach DIN 4102 B1 schwer entflammbar</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">als Unterlage für schwimmenden Estrich in Platten dicht gestoßen und stoßversetzt verlegen, Ausführung einschl. erforderlicher Zuschnitte und Anarbeitung an bauseitige Installationen, Durchgänge, Stützen, Sockel, Fassadenelementen etc.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Einbauort: Windfänge beidseits Foyer</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Trittschalldämmschicht EPS LD-CP 30-2 mm DES sg</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id3809" RNoPart="7"><Qty>122.000</Qty><QU>m²</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Liefern und verlegen einer falzfreien PE-Folie Dampfbremse/Trennlage.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">PE-Folie faltenfrei, wannenförmig auf dem in der</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Vorposition genannten Untergrund verlegen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Die Stoßüberlappung beträgt mindestens 15 cm. Den</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Nahtbereich mit zugelassenem Klebeband auf voller Länge abkleben.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Die Folie ist bis OF Estrich hochzuführen, bzw. mit dem Folienflansch zu verkleben.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Aufbauhöhe bis 110 mm.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Umlaufende Wandlänge rund 90 m.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:10pt;font-weight:bold;font-family:Arial;">Eigenschaften:</span></p><ul><li><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Dicke: 200 µ</span></p></li><li><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Rollenbreite: 2 m ohne Falz</span></p></li><li><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Dichte: 0,935 g/cm3 nach DIN 53479</span></p></li><li><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">SD-Wert: &#x3e;= 100 m nach DIN EN 1931</span></p></li></ul><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:10pt;font-weight:bold;font-family:Arial;">Ausführungsort: </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Windfängen, Technik und Lagerräumen ohne FB-Hzg.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:10pt;font-weight:bold;font-family:Arial;">Abrechnung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Abrechnung nach Grundrissfläche. Abgerechnet wird die einfache Fläche, Überlappungen und Höherführungen werden nicht gesondert vergütet und sind mit einzukalkulieren.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Trennlage PE-Folie, 0,2 mm</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id3808" RNoPart="8"><Qty>87.000</Qty><QU>m</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Liefern, montieren und zuschneiden von Randdämmstreifen für Bodenaufbau bis OK Estrich ca. 150 mm, inkl. erforderlichem Überstand an Wänden, Türzargen, Rohrleitungen etc.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Dicke: mindestens 8 mm, den Anforderungen entsprechend Höhe: mindestens 30 mm höher als Gesamtkonstruktion, nach Estricheinbau</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Einbauort: Technikräume ohne FB-Hzg</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Randdämmstreifen 150 mm</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id3837" RNoPart="9"><Qty>151.000</Qty><QU>m</QU><Description><CompleteText><ComplTSB>Yes</ComplTSB><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Liefern, montieren und zuschneiden von Mineralwolle-Randdämmstreifen für Bodenaufbau bis OK Estrich, Höhe ca. 120 mm, inkl. erforderlichem Überstand an Wänden, Türzargen, Rohrleitungen etc.,</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">inkl. hinterlaufsicherem Verkleben mit der Trittschalldämmung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Dicke: 12 mm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Laenge x Breite: 1000 mm x 120mm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Liefern und an allen aufgehenden Bauteilen verlegen. Die Randstreifen sind abzudecken und nach Fertigstellung des Oberbodenbelages abzuschneiden.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Verschnitte und Nachbesserungen sind einzukalkulieren.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Höhe: mindestens 20 mm größer als Gesamtkonstruktion, nach Estricheinbau ggf. auf dieses Maß zurückschneiden</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Fabrikat: ROCKWOOL RANDSTREIFEN RST o.glw.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"/></Text><TextComplement MarkLbl="11" Kind="Bidder"><ComplCaption><span style="font-size:11pt;font-family:Arial;">Angebotenes Produkt: </span></ComplCaption><ComplBody><span style="font-size:11pt;font-family:Arial;">&#x27;..........&#x27;</span></ComplBody><ComplTail><br/></ComplTail></TextComplement><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Bieterangabe</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Ausführung in den Fluchtwegen Foyer und beidseitige Flure</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Randdämmstreifen MiWo 120 mm</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id13184" RNoPart="10"><Qty>13.500</Qty><QU>m</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Zulage für die Anarbeitung des gesamten beschriebenenen Fußbodenaufbaus an die Rundungen der HP-Wandschalen innen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Wandschalen, Breite ca 2,00 cm, mittig konkav ca. 40 cm nach innen gewölbt.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Ausführung in Geräteraum, Technikräumen Heizung und Lüftung, Nord- und Südfassade.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Abgewickelte Länge je Schale ca. 2,25 m, </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">gesamt rd. 6 Schalen</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Zulage Anarbeitung FB.Aufbau Wandschalen</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item></Itemlist></BoQBody></BoQCtgy><BoQCtgy ID="id3810" RNoPart="03"><LblTx><p><span>Estrich</span></p></LblTx><BoQBody><Itemlist><Remark ID="id3820"><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Hinweis:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Lieferung bauseits durch Heizungsfirma:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><ul><li><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Wärme-Trittschall-Tacker-System 30/2 mm,  WLG032 mit selbstkl. Überlappung aus Polystrol (PS) Hartschaum Art und Anwendung gemäß DIN 4108-10: DES sg</span></p></li><li><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Randdämmstreifen 160 mm x 8 mm, mit Folienschürze für Tackersystem aus PE-F</span></p></li><li><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Kunststoffrohr für die Flächenheizung  PE-X 17mm</span></p></li><li><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Schutzhülse 300 mm für Rohr (Fugen an Türdurchgängen)</span></p></li></ul><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Leistungen bauseits durch Heizungsfirma:</span></p><ul><li><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Verlegung Randdämmstreifen </span></p></li><li><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Verlegung FB-Trägerplatte nach Herstellerangaben</span></p></li><li><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Leitungsinstallation FB-Heizung </span></p></li></ul></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Einbau und Lieferung bauseits durch Heizungsfirma:</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Remark><Remark ID="id3821"><Description><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Estrich</span></p></TextOutlTxt></OutlTxt></OutlineText></Description></Remark><Item ID="id3824" RNoPart="1"><Qty>257.000</Qty><QU>m²</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Faserverstärkter Zementheizestrich  CT C35 F5 S80 H64</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">auf bauseitiger Trittschalldämmplatte mit verlegten Heizleitungen einbauen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Zementestrich als Heizestrich gem. DIN 18 560, auf bauseits verlegtem Fußbodenheizsystem liefern und fachgerecht einbauen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Zementestrich dient als Untergrund für elastische und keramische Beläge (Fliesen)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Nutzlast min. 3 kN/m²,</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Beanspruchung Wohnräume mit Fußbodenheizung; Büroräume ohne Publikumsverkehr; Fabrikations-,</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Montage- und Lagerhallen für leichte Güter  gemäß Estrichmerkblatt B19</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Oberfläche gerieben und geglättet, wobei eine Mindestüberdeckung der Heizrohre von d=60mm inkl. Toleranz einzuhalten ist.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Das Einarbeiten eines Estrichzusatzmittel siehe gesondere Position.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Güteklasse: CT-C35-F5-S80-H65</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Estrichnenndicke: ca. 80 mm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Festigkeitsklasse: F5</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Bindemittel: Zement</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Verlegeart: schwimmend</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Verkehrslasten</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Flächenlasten: bis 3 kN/m²,</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Einzellasten: bis 3 KN</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Bewehrung des Estrichs mit Kunstfasern (faserverstärkt) nach Zulassung 4 kg / cbm liefern und fachgerecht einbauen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Zementestrich in richtiger Höhenlage ebenflächig nach</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Anforderungen gem. DIN 18202, Tab. 3, Zeile 3 einbauen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Das Anarbeiten an Installationen, Abläufe, Bewegungsfugen, Fugenprofilen, etc., Kellenschnitte an Einschnürungen z. B. an Türen, Ecken und Stützen, die Schein- und Arbeitsfugen sind in den EP einzurechnen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Einbauort Umkleiden, Regie-, Vereinsraum, </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">WCs und Sanitärräume gefliest, </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">siehe Fußbodenaufbau 01, 03, </span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Zementheizestrich DIN18560 CT C35 F5 S80 H64, 3 kN/m²</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id3825" RNoPart="2"><Qty>157.000</Qty><QU>m²</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Faserverstärkter Zementheizestrich  CT C35 F5 S85 H69</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">auf bauseitiger Noppenplatte / Klett-Trittschallplatte mit verlegten Heizleitungen einbauen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Zementestrich als Heizestrich gem. DIN 18 560, auf bauseits verlegtem Fußbodenheizsystem liefern und fachgerecht einbauen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Zementestrich dient als Untergrund für elastische und keramische Beläge sowie Bodenbeschichtung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Beanspruchung Wohnräume mit Fußbodenheizung; Büroräume ohne Publikumsverkehr; Fabrikations-,</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Montage- und Lagerhallen für leichte Güter  gemäß Estrichmerkblatt B19</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Oberfläche gerieben und geglättet, wobei eine Mindestüberdeckung der Heizrohre von d=65mm inkl Toleranz einzuhalten ist.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Das Einarbeiten eines Estrichzusatzmittel siehe gesondere Position.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Güteklasse: CT-C35-F5-S85-H69</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Estrichnenndicke: ca. 85 mm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Festigkeitsklasse: F5</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Bindemittel: Zement</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Verlegeart: schwimmend</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Verkehrslasten</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Flächenlasten: bis 5 kN/m²,</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Einzellasten: bis 4 KN</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Bewehrung des Estrichs mit Kunstfasern (faserverstärkt) nach Zulassung 4 kg / cbm liefern und fachgerecht einbauen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Zementestrich in richtiger Höhenlage ebenflächig nach</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Anforderungen gem. DIN 18202, Tab. 3, Zeile 3 einbauen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Das Anarbeiten an Installationen,  Abläufe, Bewegungsfugen, Fugenprofilen, etc., Kellenschnitte an Einschnürungen z. B. an Türen, Ecken und Stützen, die Schein- und Arbeitsfugen sind in den EP einzurechnen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Einbauort Foyerbereich und Flure zu Hallen und Gäste-WC</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">siehe Fußbodenaufbau 5.1</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Zementheizestrich DIN18560 CT C35 F5 S85 H69, 5 kN/m²</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id3826" RNoPart="3"><Qty>107.000</Qty><QU>m²</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Zementestrich DIN 18560 CT-C35-F5-S65</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Nutzlast 5 kN / qm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Zementestrich gem. DIN 18 560, auf verlegter Dämmung / gebundener Schüttung / PE-Folie liefern und fachgerecht einbauen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Zementestrich dient als Untergrund für elastische Beläge sowie Bodenbeschichtung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Beanspruchung entspricht ca. Fabrikations-, Montage- und Lagerhallen für leichte Güter gemäß Estrichmerkblatt B19</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Oberfläche gerieben und geglättet</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Das Einarbeiten eines Estrichzusatzmittel siehe gesondere Position.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Güteklasse: CT-C35-F5-S65</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Estrichnenndicke: ca. 65mm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Festigkeitsklasse: F5</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Bindemittel: Zement</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Verlegeart: schwimmend</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Nutzlast DIN 1055-3 Kategorie C3</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Verkehrslasten</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Flächenlasten: bis 5 kN/m²,</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Einzellasten: bis 4 KN</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Bewehrung des Estrichs mit Kunstfasern (faserverstärkt) 4 kg / cbm nach Zulassung liefern und fachgerecht einbauen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Einbau auf PE-Folie / Dämmung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Ausführung in Hausanschluss-, Technik-, Lagerräume, Windfänge Foyer unter Sauberlauf</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">siehe Fußbodenaufbau 04, 05.2 </span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Zementestrich DIN 18560 CT-C35-F5-S65</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id13135" RNoPart="4"><Qty>521.000</Qty><QU>m²</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Maschinelles Nachverdichten und Glätten der Oberfläche durch mehrmalige Bearbeitung mit Teller- und Flügelglättmaschinen zum Erreichen der für nachfolgende Linoleum oder Kunstharzarbeiten</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">erforderlichen Oberflächengüte.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Ausführung in Hausanschluss-, Technik-, Lagerräume, Windfänge Foyer unter Sauberlauf</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">siehe Fußbodenaufbau 04, 05.2 </span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Maschinelles Nachverdichten und Glätten der Oberfläche</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id3827" RNoPart="5"><Qty>521.000</Qty><QU>m²</QU><Description><CompleteText><ComplTSB>Yes</ComplTSB><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Estrichkomponente Verkürzung Abbindezeit 21 Tage</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">als Estrich- und Mörtelbettzusatzkomponente, zur Erhöhung der Estrichgüte durch höhere Plastifizierung und Verbesserung des Wasserrückhaltevermögens,  zur schnelleren Erhärtung (Frühhochfestigkeit) des Estrichs.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Für Nutzlast bis 5 kN/qm</span><br/><span style="font-size:11pt;font-family:Arial;">Abbindezeit: 21 Tage</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Leitfabrikat: Uponor Estrichkomponente VD 450 o.glw.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"/></Text><TextComplement MarkLbl="11" Kind="Bidder"><ComplCaption><span style="font-size:11pt;font-family:Arial;">Angebotenes Fabrikat: </span></ComplCaption><ComplBody><span style="font-size:11pt;font-family:Arial;">&#x27;..........&#x27;</span></ComplBody><ComplTail><br/></ComplTail></TextComplement><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">(Bieterangabe)</span><br/></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Abrechnung nach qm Estrich,</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">für Verbauch anzunehmende Stärke 60-85mm entsprechend Estrichpositionen</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Estrichkomponente Verkürzung Abbindezeit 21 Tage</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id3823" RNoPart="6"><Qty>109.000</Qty><QU>m²</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Mehr-/Minderdicke je 5 mm </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Differenzpreis für je 5 mm Estrich Mehr-/Minderstärke des Zementestriches, Minderstärke wird im Preis abgezogen </span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Mehr-/Minderdicke je 5 mm</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id3830" RNoPart="7"><Qty>70.000</Qty><QU>m²</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Zulage für die Verlegung des Estrichs im Gefälle </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Absenkung in der Estrichfläche an Bodenabläufen und im gesamten Duschraum mit vierseitig zur Rinne angelegten Gefälle auf dem unter Position </span><span style="font-size:11pt;font-family:Arial;">02.2</span><span style="font-size:11pt;font-family:Arial;"> angelegten Gefälle.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Der Estrich ist im unmittelbaren Bereich des Bodenablaufs, vierseitig nach Angabe Architekt abzusenken.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Die Anarbeitung an den bauseits eingebauten Bodenablauf /Duschrinne ist Bestandteil der Leistung.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Abmessung von ca. 100 x 100 cm bis Duschraum 200 x 225 cm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Ausführung entsprechend Fliesenplänen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">einschl. Abstimmung mit Heizungsbauer zum Freihalten der Bereiche von Fußbodenheizungsrohre zur Gewährleistung einer annähernd gleichbleibenden Estrichnutzstärke gemäß Vorgabe DIN 18560-2</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Der in der Fläche höhenmäßig abgesetzte Einbau für die Sauberlaufmatten (2 Stk. Breite ca. 1.80 m, Länge 4,60 m) im Foyer/Windfang ist in den Massen dieser Position mit erfasst. </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Abrechnung in qm</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Zulage Gefälleausbildung Estrich</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id3840" RNoPart="8"><Qty>11.000</Qty><QU>Stk</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Anarbeiten an Betonstützen, bis 40 / 40 cm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Anarbeiten des vorbeschriebenen Zementheizestrichs an</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Betonstützen, einschl. Abstellen des Randdämmstreifens</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><ul><li><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">für Stützen bis 40 /40 mm</span></p></li><li><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">10  x 2 - seitiges Anarbeiten</span></p></li><li><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">1 x 3 - seitiges Anarbeiten</span></p></li></ul><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Ort: Sozialtrakt Bestand</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Anarbeiten an Betonstützen, bis 40 / 40 cm</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id3831" RNoPart="9"><Qty>521.000</Qty><QU>m²</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Abdeckung als besonderer Schutz des Estrichs gegen Zugluft und Verschmutzung nach Anweisung der örtlichen Bauleitung liefern und herstellen, einschl. der späteren Beseitigung. Abdeckung aus Kunststoff-Folie, Dicke 0,2 mm, einlagig, Stöße lose überlappen, Ränder kleben.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Zusätzlich mit Bohlen und Kanthölzern zum Beschweren</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">der Ränder und Fugen abdecken.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Abrechnung nach Raumgrundfläche</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Abdeckung als besonderer Schutz des Estrichs</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Remark ID="id3834"><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Fugen</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Fugen</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Remark><Item ID="id3835" RNoPart="10"><Qty>75.000</Qty><QU>m</QU><Description><CompleteText><ComplTSB>Yes</ComplTSB><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Herstellen und Verdübeln der Dehnfugen im Heizestrich an Türen und in der Fläche und zur Trennung der Heizkreise mit Fugenprofil und Dübeln zur Vermeidung des Aufschüsselns im Trocknungsprozess.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Höhe 100 mm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Breite 8-10 mm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Rohrdurchführungen der FB-Heizung sauber ausschneiden und Profil mit Klebeband auf Tacker-/Rasterplatte fixieren. </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Im Preis inbegriffen sind alle Zuschnitte, Passstücke und Anschlüsse an Stützen, Leitungen und Wände.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">einschließlich der Verdübelung mit Querkraft-Estrichdübel mit Trittschallschutz im Abstand von 25cm, bei Herstellung in den Estrich einarbeiten.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Ø 6-10 mm, Länge 300 mm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Die Fugen müssen entsprechend Fugenplan und absolut gerade ausgeführt werden, ggf. hierfür notwendige Hilfskonstruktionen sind einzukalkulieren.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"/></Text><TextComplement MarkLbl="11" Kind="Bidder"><ComplCaption><span style="font-size:11pt;font-family:Arial;">angebotenes System/Produkt: </span></ComplCaption><ComplBody><span style="font-size:11pt;font-family:Arial;">&#x27;..........&#x27;</span></ComplBody><ComplTail><br/></ComplTail></TextComplement><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">(Bieterangabe)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Ausführung gemäß Estrichfugenplan im Foyer, Technik, in Durchgängen unter Türblättern, vor Estrich-Abstellwinkel zum Sportboden,</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">PE-Dehnfugenprofil Heizestrich mit Verdübelung</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id3836" RNoPart="11"><Qty>10.000</Qty><QU>m</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Anordnung erforderlicher Schein- und Arbeitsfugen gemäß DIN 18 560-2, Abschnitt 5.3.3 in Abhängigkeit von Flächengröße und Raumgeometrie in Zementestrich ohne Fussbodenheizung inkl. Querkraftverdübelung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Technikräume, Lager</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Schein- und Arbeitsfugen</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id3839" RNoPart="12"><Qty>10.000</Qty><QU>m</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Estrichfugen ( Schein- oder Bewegungsfugen ) sowie</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Anschlussfugen zwischen Anhydrit- und Zementestrich mit Epoxidharz schließen, klammern und absanden.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Fugenbreite: bis ca. 10 mm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Herstellerrichtlinien sind zu beachten.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Estrichfugen verharzen und verklammern</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Remark ID="id3828"><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Einbauten</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Einbauten</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Remark><Item ID="id2118" RNoPart="13"><Qty>6.750</Qty><QU>m</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Liefern und montieren von gekanteten Blechwinkeln, feuerverzinkt, Schenkellänge 190 bis 250 mm, vor Öffnungen am Übergang zwischen Estrichboden und Sportboden (Halleneingänge) auf der bituminösen Abdichtung verkleben und seitlich vor den Türlaibungen verdübeln zur Abstellung des Bodenaufbaus.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Einschl. Rückenabstützung währende Estricheinbaus</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Eingang Neubauhalle </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Winkel 190/250mm, Länge 2750 mm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Eingänge Altbauhalle </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Winkel 190/250 mm. Länge 2300 mm und 1700 mm</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Abstellwinkel Estrich 3 mm, Höhe 240 bis 260 mm, S235</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id3829" RNoPart="14"><Qty>30.000</Qty><QU>Stk</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Zulage für Heizestriche für folgende Leistungen:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Anlegen  und  Kennzeichnen  von  Messstellen  für  Feuchtigkeitsmessung nach CM-Methode</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Estrich-Messstellen</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id3838" RNoPart="15"><Qty>10.000</Qty><QU>Stk</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Aussparung im Zementestrich </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">nach Planung und Vorgabe Bauleitung herstellen (für nachträgliche Installationen o.ä.).</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Abmessungen bis zu 0,5 qm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">inkl. nachträglichem Schließen des gesamten Fußbodenaufbaus einschl. Schnellzementestrich entspr. v.g. Anforderungen aus Ausführungsbeschreibung der Hauptposition mit Trittschalldämmung an durchdringende Bauteile anarbeiten.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Estrichstärke 60-80mm</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Trittschall EPS 045 DES sg 30/2</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Aussparungsgröße bis 0,5 m²</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Nur auf Anweisung Bauleitung.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Aussparung im Zementestrich herstellen und nachtr. schließen</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item></Itemlist></BoQBody></BoQCtgy><BoQCtgy ID="id3811" RNoPart="04"><LblTx><p><span>Prüfungen, Nachweise, Sonstiges</span></p></LblTx><BoQBody><Itemlist><Item ID="id3813" RNoPart="1"><Qty>4.000</Qty><QU>Stk</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Überprüfen der Haftzugfestigkeit der vorbereiteten</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Oberfläche im Beisein der Bauleitung gem. DAfStb-</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Richtlinie Schutz und Instandsetzung von</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Betonbauteilen (Rili-SIB, 2001) bzw. ZTV-ING. Die</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Ergebnisse (Prüfstelle, Werte, Trennfall) sind in einem</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Protokoll festzuhalten und der Bauleitung zu</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">übergeben. Liegen die Werte außerhalb der vom</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Materialhersteller vorgegebenen Grenzwerte, sind mit</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">der Bauleitung weitere Maßnahmen abzusprechen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:10pt;font-weight:bold;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:10pt;font-weight:bold;font-family:Arial;">Gemeinsame Durchführung mit Objektüberwachung</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Prüfung der Haftzugfestigkeit</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id3814" RNoPart="2"><Qty>8.000</Qty><QU>Stk</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Estrich auf Restfeuchtegehalt überprüfen (CM-Methode).</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Einschl. voriger Abstimmung Abbindebeschleuniger und Übergabe Protokoll mit Heizkurve an den TGA-Planer und Heizungsbauer.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Nach der prognostizierter Belegereife gem. vorgegebener Ausführungsvariante wird die Belegreife durch den AN mittels CM-Messung gemessen und protokolliert. Die Prüfung erfolgt mit Prüfgut, welches aus dem kompletten Estrichquerschnitt entnommen wurde.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Je Raum ist eine Messungen vorzunehmen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Die Durchführung und Protokollierung der CM-Messung erfolgt gemäß Arbeitsanweisung/Dokumentation FBH-AD der Schnittstellenkoordination.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Restfeuchtegehalt des Zementestrichs für die Verlegung eines Fliesenbelags oder Linoleums: max. 2,0 CM-%</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Freigabe zur Belegung für nachfolgende Gewerke gemäß Merkblatt der Fußbodenheizungshersteller.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;"> </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:10pt;font-weight:bold;font-family:Arial;">Gemeinsame Durchführung mit Objektüberwachung</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Restfeuchtemessung Estrich (CM-Methode)</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id3816" RNoPart="3"><Qty>200.000</Qty><QU>d</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Radiallüfter</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Luftumwälzung (m³/h): 4250</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Gebläsestufen: 3 Stufen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Leistung Gebläsestufen (m³/h): 1416 - 2832 - 4250</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Drehzahl (U/min): 800 - 900 - 1000</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Luftdruck (Pa): 500</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Leistungsaufnahme (Watt): 700 - 730 - 850</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Spannung (V/Hz): 230/50</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Geräuschpegel bei 3m (dB): 76</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">einschl. Verlängerungskabel 20 m,</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">liefern, aufstellen, vorhalten und wieder abfahren.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Radiallüfter für Estrichtrocknung</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id21932" RNoPart="4"><Qty>8.000</Qty><QU>m³</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Container 8 m³ für Baustellenabfälle ASN 170904 vorhalten für die Entsorgung von Abfällen aus Fremdgewerken der Baumaßnahme, einschl. An- und Abfahren des Containers und aller Nebenkosten.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Nur auf Anweisung der Bauleitung und nur für Materialien, die keiner anderen ASN zugeordnet werden können. </span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Container 8 m³ gemischter Bau- und Abbruchabfall ASN 17 09 04</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item></Itemlist></BoQBody></BoQCtgy><BoQCtgy ID="id3812" RNoPart="05"><LblTx><p><span>Stundenlohnarbeiten</span></p></LblTx><BoQBody><Itemlist><Remark ID="id3817"><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Stundenlohnarbeiten dürfen nur dann ausgeführt werden, wenn sie vom Auftraggeber bzw. der Bauleitung im Einzelfall angeordnet werden.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Die aufgewendeten Stunden, verwendeten Geräte,Transportleistungen und verbrauchten Stoffe werden in die Stundenlohnnachweise täglich eingetragen und dem Auftraggeber zur Gegenzeichnung innerhalb einer Kalenderwoche vorgelegt bzw. elektronisch zugestellt.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Die Bestimmungen, wonach bei Mengenänderungen die Neuvereinbarung von Einheitspreisen verlangt werden kann, sind auf Regieleistungen nicht anwendbar.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Stundenlöhne werden nur mit dem Preisanteil Lohn abgerechnet. Bei Gerätebeistellungen, Transportleistungen, Stoffbeistellungen und Fremdleistungen werden die Einheitspreise in Lohn und Sonstiges aufgegliedert.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">In den Stundensätzen sind auch anteilige Wegegelder, Fahrtspesen und Aufwandsentschädigungen (Auslösen) einkalkuliert.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Verrechnet wird die an der Arbeits- oder Montagestelle tatsächlich geleistete Arbeitszeit, die kleinste Einheit ist die angefangene halbe Stunde. Zur Verrechnung kommen die Stundensätze jener Beschäftigungsgruppe, die für die jeweilige Regieleistung ausreicht, unabhängig von der Qualifizierung des tatsächlich eingesetzten Personals.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Die Einheitspreise für Stoffe gelten frei Baustelle, einschließlich Abladen.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Stundenlohnarbeiten</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Remark><Item ID="id3818" RNoPart="1"><Provis>WithoutTotal</Provis><HourIt>Yes</HourIt><Qty>1.000</Qty><QU>h</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Stundenlohnarbeiten eines </span><span style="font-size:11pt;font-family:Arial;">Vorarbeiter / Polier </span><span style="font-size:11pt;font-family:Arial;">auf Anweisung der Bauleitung.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Stundenlohn Vorarbeiter / Polier</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id3819" RNoPart="2"><Provis>WithoutTotal</Provis><HourIt>Yes</HourIt><Qty>1.000</Qty><QU>h</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;"><span style="font-size:11pt;font-family:Arial;">Stundenlohnarbeiten von Hilfskräften auf Anweisung der Bauleitung.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:595pt;margin-top:0pt;margin-bottom:0pt;"><span style="font-size:11pt;font-family:Arial;">Stundenlohn Hilfskräfte</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item></Itemlist></BoQBody></BoQCtgy></BoQBody></BoQ></Award></GAEB>