<?xml version="1.0" encoding="UTF-8"?>
<GAEB xmlns="http://www.gaeb.de/GAEB_DA_XML/DA83/3.3"><GAEBInfo><Version>3.3</Version><VersDate>2021-05</VersDate><Date>2026-02-10</Date><Time>11:35:15</Time><ProgSystem>FUTURA</ProgSystem><ProgName>FUTURA Version 9.1.03.77</ProgName></GAEBInfo><PrjInfo><NamePrj>DU-StA K</NamePrj><LblPrj>DU-StA Kleve, KNLV Projekt</LblPrj><Cur>EUR</Cur><CurLbl>Euro</CurLbl></PrjInfo><Award><DP>83</DP><AwardInfo><Cur>EUR</Cur><CurLbl>Euro</CurLbl></AwardInfo><OWN><Address><Name1>Bau- und Liegenschaftsbetrieb NRW</Name1><Name2>NL Duisburg</Name2><Street>Am Silberpalais 1</Street><PCode>47057</PCode><City>Duisburg</City><Phone>0203-98711-0</Phone><Fax>0203-98771-900</Fax><Email>0203-du.poststelle@blb.nrw.de</Email></Address></OWN><BoQ ID="OID_74"><BoQInfo><Name>054</Name><LblBoQ>Erneuerung NSHV - Beleuchtung KG</LblBoQ><OutlCompl>AllTxt</OutlCompl><BoQBkdn><Type>BoQLevel</Type><LblBoQBkdn>Titel</LblBoQBkdn><Length>2</Length><Num>Yes</Num></BoQBkdn><BoQBkdn><Type>BoQLevel</Type><LblBoQBkdn>Untertitel</LblBoQBkdn><Length>2</Length><Num>Yes</Num></BoQBkdn><BoQBkdn><Type>Item</Type><Length>4</Length><Num>Yes</Num></BoQBkdn><BoQBkdn><Type>Index</Type><Length>1</Length><Num>No</Num><Alignment>left</Alignment></BoQBkdn><Ctlg><CtlgID>CAGJAFNI</CtlgID><CtlgType>work category</CtlgType><CtlgName>noname</CtlgName></Ctlg><Ctlg><CtlgID>CAGLAFJN</CtlgID><CtlgType>cost group DIN 276-81</CtlgType><CtlgName>DIN 276-81</CtlgName></Ctlg><Ctlg><CtlgID>CAGHBJAE</CtlgID><CtlgType>cost group DIN 276-93</CtlgType><CtlgName>DIN 276-93</CtlgName></Ctlg><Ctlg><CtlgID>CAGAFDTR</CtlgID><CtlgType>cost group DIN 276-06</CtlgType><CtlgName>DIN 276-06</CtlgName></Ctlg><Ctlg><CtlgID>CAGHUSDF</CtlgID><CtlgType>cost group DIN 276-1 2008-12</CtlgType><CtlgName>DIN 276-1 2008-12</CtlgName></Ctlg><Ctlg><CtlgID>CAGHUSDG</CtlgID><CtlgType>miscellaneous</CtlgType><CtlgName>cost group DIN 276 2018-12</CtlgName></Ctlg><Ctlg><CtlgID>CAGHUSDH</CtlgID><CtlgType>miscellaneous</CtlgType><CtlgName>LB-DIN</CtlgName></Ctlg><Ctlg><CtlgID>CAGMAAAM</CtlgID><CtlgType>locality</CtlgType><CtlgName>noname</CtlgName></Ctlg><Ctlg><CtlgID>CAIGFLAA</CtlgID><CtlgType>cost unit</CtlgType><CtlgName>noname</CtlgName></Ctlg></BoQInfo><BoQBody><BoQCtgy ID="OID_76" RNoPart="01"><LblTx><span>Allgemeine Vorbemerkungen</span></LblTx><BoQBody><Itemlist><Remark ID="ID_542"><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;font-weight:bold;">Allgemeine Vorbemerkungen</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;font-weight:bold;">Objektbeschreibung</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Bei dem vorhandenen Gebäude handelt es sich um das Gebäude der Staatsanwaltschaft Kleve, welches 1937 errichtet wurde.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Das Gebäude besteht aus Kellergeschoss, zwei Vollgeschossen und einem Dachgeschoss mit Satteldach.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Das rechteckige Gebäude liegt auf einem Eckgrundstück und geht entlang der Graf - Johan- Straße, Kasinostraße und der Ringstraße mit einem Parkplatz im Innenhof.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Der Haupteingang des Gebäudes ist zur Ringstraße gerichtet und wird während der Bauzeit weiter benutzt.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die Fassade besteht aus Klinker mit Naturstein im Sockel und Kellerbereich. Das Mauerwerk ist monolithisch aus Ziegelmauerwerk errichtet.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Anschrift:</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Staatsanwaltschaft Kleve</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Ringstraße 13</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">47533 Kleve</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;font-weight:bold;">Lageplatz</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die Lagerung von Material muss in Abstimmung mit der Hausverwaltung der</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Staatsanwaltschaft (StA) erfolgen. Die vorgegebenen Verkehrswege sind einzuhalten.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Absperrungen und Umfahrungen sowie Rettungswegzufahrten für die Feuerwehr im Brand und Gefahrenfall sind zu berücksichtigen und ständig freizuhalten. Dies gilt insbesondere für die Aufstellung von Containern.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;font-weight:bold;">Sicherheits- und Schutzmaßnahmen</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Der Betriebsablauf ist vorrangig. Die Bedürfnisse der Sicherheit, der Flucht - und Rettungswege aus dem Gebäude sind bei der Baustelleneinrichtung und während der Bauzeit zu gewährleisten.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Bei der Kalkulation ist zu berücksichtigen, dass es sich um Arbeiten in einer StA handelt, die unter</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">erschwerten Bedingungen bezüglich des Personaleinsatzes, der täglichen Ausweiskontrolle, der</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Arbeitszeiten, der Baustelleneinrichtung, der Baustellensicherung, sowie des An- und Abtransportes von Materialien, durchzuführen sind.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Arbeiten des ANs, die den Betriebsablauf beeinträchtigen können, dürfen demzufolge nur nach</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">ausdrücklicher Genehmigung durch die StA durchgeführt werden. Das Einholen der hierfür erforderlichen</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Genehmigung ist Sache des ANs. Der Ansprechpartner in der StA wird nach Auftragsvergabe benannt.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Bei den Arbeiten sind Geräte und Materialien nach Angaben der Geschäftsleitung bzw. der Personen die für Sicherheit und Ordnung zuständig sind zu sichern. Während der Arbeiten ist darauf zu achten, dass Werkzeuge und Material zu keiner Zeit unbeaufsichtigt herumliegen.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die Vorschriften der Berufsgenossenschaft unter Zugrundelegung der Unfallverhütungsvorschriften und der Baustellenverordnung (BauStellV), einschließlich dem Arbeitsschutzgesetz und der anhängigen Verordnungen (z.B. zur Gefahrstoffverordnung, usw.) sind zu beachten.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;font-weight:bold;">Dienstzeiten</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die Arbeitszeiten in der StA sind wie folgt festgelegt:</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Montag bis Freitag: 7:30 - 16:00 Uhr</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Außerhalb dieser Zeiten können im Regelfall aus vollzugstechnischen Gründen keine Arbeiten ausgeführt werden.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;font-weight:bold;">Organisation der Arbeit</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Bauwasser und Strom werden kostenfrei zur Verfügung gestellt. Das Heranführen von Entnahmestellen zum Baustellenbereich geht zu Lasten des AN.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Soweit nicht gesondert in Positionen erfasst, sind die Baustellenrichtung und die Schuttbeseitigung, sowie alle dazu notwendigen Leistungen in den Positionen einzurechnen.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die Anhäufung von Material und Abfällen (Brandlast) ist zu vermeiden. Material sollte nur entsprechend dem Baufortschritt und dem Tagesbedarf in das Gebäude gebracht werden. Abfälle sind nach Beendigung der Arbeiten, mindestens jedoch arbeitstäglich, aus den Gebäuden zu entfernen und ordnungsgemäß zu beseitigen. Die Baustelle ist werktäglich besenrein zu verlassen.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Sämtliche Risiken der Verwahrung eventuell vom AG beigestellten Anlagen und Materialien bis zur</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Abnahme der durch den AN zu erbringenden Leistungen trägt der AN.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Mindestens 1 Beschäftigter des AN, welcher ständig vor Ort ist, muss Deutsch in Wort und Schrift</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">beherrschen, damit den Sicherheitsanweisungen Folge geleistet werden kann.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Der AN ist verpflichtet, täglich Bautageberichte zu führen. Die Bautageberichte müssen die folgenden Angaben enthalten: Anzahl und Name der Mitarbeiter, Dauer und kurze Beschreibung der ausgeführten Arbeiten.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die Bautageberichte sind der örtlichen Fachbauleitung spät. 7-tägig zu übergeben. Dieses gilt gleichermaßen für Nachunternehmer die ggf. durch den AN eingesetzt werden.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die Abrechnung erfolgt auf Grundlage der durch Aufmaße belegten Leistungen.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Bei den im folgenden LV genannten Positionen sind während der Bauzeit entsprechende</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Schutzmaßnahmen (Abdecken mit Folie) sowie ein einmaliges Säubern kurz vor der Abnahme</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">durchzuführen und mit in die Einheitspreise der Positionen einzukalkulieren.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;font-weight:bold;">Kalkulationhinweise</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die durch die Beauftragung festgelegten Leistungen/Lieferungen werden mit den vereinbarten Preisen abgegolten.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Mit den vereinbarten Preisen sind insbesondere abgegolten: Lohnkosten und Lohnnebenkosten aller Art einschl. Auslösungen, Wegegelder, Reisekosten und Kosten für Unterbringung auswärtiger Arbeitskräfte, Sämtliche Gemeinkosten und Zuschläge des Auftragnehmers, Kosten für Erschwernisse und Behinderungen.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Ferner sind einzukalkulieren: Montagegerüste (Blockgerüste), Leitern, Vorrichtungen, elektr. sowie</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">akkubetriebene Geräte und Werkzeuge für die Montagen bzw. für die Demontagen in den einzelnen Gebäudeabschnitten.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Alle im LV genannten Positionen verstehen sich gemäß VOB inkl. Lieferung und Montage.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;font-weight:bold;">Inbetriebnahme und VOB Abnahme</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">14 Tage vor dem VOB Abnahmetermin hat der Auftragnehmer die für die Abrechnung seiner Bauleistungen vollständigen Dokumentationsunterlagen einzureichen.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Der Auftragnehmer ist verpflichtet, dem Bauherrn oder dem von ihm bestellten Vertreter bei der Abnahme für die von ihm erbrachten Leistungen Bescheinigungen, Prüfberichte, Unterlagen, Datenblätter und dergleichen zu übergeben.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Ohne Vorlage dieser Unterlagen wird keine Abnahme durchgeführt.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die Gewährleistungsfrist nach VOB beträgt 4 Jahre.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Allgemeine Vorbemerkungen</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Remark></Itemlist></BoQBody></BoQCtgy><BoQCtgy ID="OID_77" RNoPart="02"><LblTx><span>Elektro</span></LblTx><BoQBody><BoQCtgy ID="OID_78" RNoPart="01"><LblTx><span>Niedersannungsschaltanlagen</span></LblTx><BoQBody><Itemlist><Item ID="ID_543" RNoPart="0001"><Qty>1.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Zählerschranksystem</span><br/></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Art und Aufbau gemäß den aktuellen VDE und DIN Vorschriften.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Der Zählerschrank ist mit Zu-und Abgangsklemmen zum Anschluss mehrerer Stromkreisleitungen mit getrennten N-und PE- Schienen sowie Nulleitertrennklemmen einschl. Sicherungsmaterial zu liefern.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Alle Adern sind auf Reihenklemmen zu führen. Bis 10 mm Durchmesser sind Trennklemmen einzusetzen, darüber sind N und PE auf Schienen mit Reiterklemmen anzuschließen</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Sämtliche NH-Sicherungstrenner und Neozed Sicherungstrennschalter sind mit Sicherungen bestück zu liefern.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Zuleitungen, auch von einpoligen Leitungsschutzschalter, sind generell auf dreipolige Klemmen aufzulegen.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Stromlauf- und Aufbaupläne entsprechend den gültigen VDE-Vorschriften sind zu erstellen und vor Montagebeginn der Installationsarbeiten vorzulegen.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">An der Innenseite der Tür ist eine Tasche aus Klarsichtfolie anzubringen, die zur Aufnahme. der Schaltpläne, die gedruckt anzufertigen sind, dient.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die gravierten Bezeichnungsschilder auf den Frontplatten sind jeweils den Sicherungen, Automaten, Tastern und Schaltern der jeweiligen Stromkreise zugeordnet und dauerhaft haltbar anzubringen.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die Leistungsschalter sind mit elektronischen</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Ueberstromausloeser und Primaerstromwandler</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">auszuruesten.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die Festeinbau-Leistungsschalter sind zu- und</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">abgangsseitig fuer festen Anschluss vorzusehen</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Der Zählerverteilung ist gem. den geltenden DIN VDE -</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;"> Bestimmungen komplett zusammengebaut und</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;"> verdrahtet, anschlussfertig zu liefern und zu</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;"> montieren.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;"> Die Ausführung erfolgt nach den anerkannten Regeln</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;"> der Technik. Hierzu ist mindestens der jeweils</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;"> aktuelle Normenstand zu realisieren.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Verteilerschrank-System/Betriebsmittel einschließlich</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;"> allem benötigtem Systemzubehör,</span><br/></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Mit dem Bau darf erst nach Genehmigung durch den</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;"> Auftraggeber / Planer begonnen werden.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;"> Zur Genehmigung sind Frontansicht mit</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;"> Betriebsmittelaufteilung einzureichen.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die Anlage ist nach den Vorgaben des Netzbetreibers</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;"> (EVU) aufzubauen.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;"> Die Abstimmungsgespräche mit dem EVU sind</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;"> mit im Angebotspreis einzukalkulieren.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Ergänzend zum zuvor beschriebenen betriebsfertig Bestück mit folgenden Einbauteilen, deren Abrechnung über gesonderte Positionen erfolgt.:</span><br/></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Technische Daten:</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Nennspannung: 500 V</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Betriebsspannung: 230/400 V</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Frequenz: 50 Hz</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Schutzart: IP 55</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Aufbau: Schutzklasse 2 (schutzisoliert)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Nennstrom 250 A oder 355 A</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Maße (HxBxT): 1400mm x 2450 x 215mm</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">1x Einspeisegehäuse</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">3x Stück leistungsschalter - 120A</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">1x Kombiableiter Typ 1 + 2</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">3x NH 1 Lasttrennschalter 3. pol</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">3 x D00 Lasttrennschalter 3 pol.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">3 Stück Neozed Sicherungslasttrennschalter 3-polig D02 bis 63A</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">3x Vorichtung für Stromwandler</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>ZHV</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_544" RNoPart="0002"><Qty>1.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Standverteiler als schutzisolierte, fabrikfertige Schaltgeräte-Kombination in berührungssicherer a.P.- Ausführung, komplett verdrahtet mit Resopalschildern beschriftet, inkl. allem wie nachfolgend beschrieben, liefern, montieren und betriebsbereit anschließen.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Art und Aufbau gemäß den aktuellen VDE und DIN Vorschriften.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Verteilung mit Abschlusstür in verwindungsfreier Ausführung, abschließbar mit Halbprofilzylinderaufnahme, einschl. deren Einbauteile, Sammelschienen, Verdrahtungsmaterial, Frontabdeckungen, Abdeckstreifen der Einbauverteiler, Berührungsschutz und Leitungseinführungen.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die Verteilung ist mit Zu-und Abgangsklemmen zum Anschluss mehrerer Stromkreisleitungen mit getrennten N-und PE- Schienen sowie Nulleitertrennklemmen einschl. Sicherungsmaterial zu liefern.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Alle Adern sind auf Reihenklemmen zu führen. Bis 10 mm Durchmesser sind Trennklemmen einzusetzen, darüber sind N und PE auf Schienen mit Reiterklemmen anzuschließen</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Sämtliche NH-Sicherungstrenner und Neozed Sicherungstrennschalter sind mit Sicherungen bestück zu liefern.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Zuleitungen, auch von einpoligen Leitungsschutzschalter, sind generell auf dreipolige Klemmen aufzulegen.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Bei Steuerungen für Beleuchtungen oder Motoren, sind für die Steuerleitungen und Lastleitungen separate Klemmen zu berücksichtigen.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Stromlauf- und Aufbaupläne entsprechend den gültigen VDE-Vorschriften sind zu erstellen und vor Montagebeginn der Installationsarbeiten vorzulegen.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Über dem gesamten Verteilerfeld ist ein freier Raum von ca. 30 cm Höhe hinter den Frontblenden vorzusehen, der zur Aufnahme der Abgangs- und Trennklemmen dient.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">An der Innenseite der Tür ist eine Tasche aus Klarsichtfolie anzubringen, die zur Aufnahme. der Schaltpläne, die gedruckt anzufertigen sind, dient.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die gravierten Bezeichnungsschilder auf den Frontplatten sind jeweils den Sicherungen, Automaten, Tastern und Schaltern der jeweiligen Stromkreise zugeordnet und dauerhaft haltbar anzubringen.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die noch nachfolgend aufgeführten Geräte sind im Verteilerfeld übersichtlich anzuordnen und unter Verwendung der VDE-Farben werkseitig zu verdrahten, betriebsbereit anzuschließen, auf Nennwerte einzustellen und mit Resopalschildern zu beschriften.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Technische Daten:</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Nennspannung: 500 V</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Betriebsspannung: 230/400 V</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Frequenz: 50 Hz</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Schutzart: IP 54</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Aufbau: Schutzklasse 2 (schutzisoliert)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Maße (HxBxT): 1950mm x 1300mm x 275mm</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">benötigte Platzeinheiten: ca. PLE312</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Ergänzend zum zuvor beschriebenen betriebsfertig Bestück mit folgenden Einbauteilen, deren Abrechnung über gesonderte Positionen erfolgt.:</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">1 Stück leistungsschalter - 200A</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">1 Stück Blitzstromableiter als Typ 1&amp;2 für L1, L2, L3, N gegen PE</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">16 Stück Neozed Sicherungslasttrennschalter 3-polig D02 bis 63A</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">15 Stück Sicherungslasttrennschalter 3-polig 63 A, mit Anschlussklemmen D01 und D02</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">11x FI-Schutzschalter 4P, Typ A, 40A,</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">30mA, kurzzeitverz.</span><br/></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">70 x B16 Sicherungsautomat B-Char., 6 kA, 16 A 1p.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">5 x B16 Sicherungsautomat B-Char., 6 kA, 16 A 3p</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">2 Stück Installationsschütz 25A 4 Schließer 230/400V</span><br/></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>GHV</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_545" RNoPart="0003"><Qty>1.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:#373737;font-family:'Arial';font-size:10pt;">Elektronischer Haushaltszähler eHz nach FNN- Lastenheften für eHz -Version 2.1 und EDL Version 1.1. MID- konform und geeicht. Mehrphasen-Wechselstrom-Zweienergierichtungszähler, Genauigkeitsklasse A, zur Montage auf Befestigungs- und Kontaktiereinrichtungen nach DIN V VDE 0603-5 (VDE V 0603-5). Betrieb als Mehrphasen- oder Einphasen-Wechselstromzähler. Zwei Tarifregister und Summenregister zur Zählung von Wirkenergieverbrauch und - lieferung. Für externer Tarifsteuerung über rückseitige Schnittstelle. Kontrollanzeige für Phasenbelegung und Drehfeldrichtung. Hohe magnetische Immunität &gt; 380mT. Anzeigefunktionen für abrechnungsrelevante Verbrauchsdaten, zusätzlich Momentanleistung und kumulierte Verbrauchsanzeige für 1 Tag, 7 Tage, 30 Tage, 365 Tage, individuelle rücksetzbare Verbrauchsanzeige, nicht sperrbar über Schutzcode. </span></p><p style="font-family:'Arial';font-size:10pt;"><span style="color:#373737;font-family:'Arial';font-size:10pt;"></span></p><p><span style="color:#373737;font-family:'Arial';font-size:10pt;">Nennspannung: 230/400 V</span></p><p><span style="color:#373737;font-family:'Arial';font-size:10pt;">Frequenz: 50 Hz</span></p><p><span style="color:#373737;font-family:'Arial';font-size:10pt;">Anzahl Module: 5</span></p><p><span style="color:#373737;font-family:'Arial';font-size:10pt;">Tiefe installiertes Produkt: 93 mm</span></p><p><span style="color:#373737;font-family:'Arial';font-size:10pt;">Betriebsstrom: 0.1 / 60 A</span></p><p><span style="color:#373737;font-family:'Arial';font-size:10pt;">Leistungsaufnahme: 0.2 VA</span></p><p><span style="color:#373737;font-family:'Arial';font-size:10pt;">Montageart: Gerastet</span></p><p><span style="color:#373737;font-family:'Arial';font-size:10pt;">Polart: 3P+N</span></p><p><span style="color:#373737;font-family:'Arial';font-size:10pt;">Anzeige Einheit Energie: 1 kWh</span></p><p><span style="color:#373737;font-family:'Arial';font-size:10pt;">Genauigkeitsklasse: 1%</span></p><p><span style="color:#373737;font-family:'Arial';font-size:10pt;">Versorgungsspannung: 400 V ± 20%</span></p><p><span style="color:#373737;font-family:'Arial';font-size:10pt;">Zähleraufnahme: Tarifzähler</span></p><p><span style="color:#373737;font-family:'Arial';font-size:10pt;">Übersetzungsverhältnisses einstellbar: Nein</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>eHz Zweirichtungszähler</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_546" RNoPart="0004"><Qty>1.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>054</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>054</WCtg><Group>3466</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>319</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>985</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11903</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6578</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>12</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>29</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12491</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5753</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10554</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>62</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5741</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>37</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12481</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12438</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>5</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12458</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>42</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>7800</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>13</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Lasttrennschalter DIN EN IEC 60947-3 (VDE 0660-107), als Hauptschalter, gekapselt, 3-polig, Bemessungsbetriebsspannung 690 V AC, in Festeinbautechnik, mit Handantrieb, zur Montage auf Tragschiene DIN EN 60715 (VDE 0660-520), abschließbar, fingersicher DIN EN 50274 (VDE 0660-514), Gebrauchskategorie AC-21, Bemessungsbetriebsstrom 200 A, Gehäuse aus Kunststoff.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Lasttrennschalter Hauptschalter 3polig 690VAC AC-21 200A</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_547" RNoPart="0005"><Qty>3.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>054</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>054</WCtg><Group>3466</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>319</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>985</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11903</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6578</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>12</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>29</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12491</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5753</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10554</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>62</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5741</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>37</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12481</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12438</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>5</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12458</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>43</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>7800</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>13</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Lasttrennschalter DIN EN IEC 60947-3 (VDE 0660-107), als Hauptschalter, gekapselt, 3-polig, Bemessungsbetriebsspannung 690 V AC, in Festeinbautechnik, mit Handantrieb, zur Montage auf Tragschiene DIN EN 60715 (VDE 0660-520), abschließbar, fingersicher DIN EN 50274 (VDE 0660-514), Gebrauchskategorie AC-21, Bemessungsbetriebsstrom 125 A, Gehäuse aus Kunststoff.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Lasttrennschalter Hauptschalter 3polig 690VAC AC-21 125A</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_548" RNoPart="0006"><Qty>2.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>050</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2022-04</VersDate><WCtg>050</WCtg><Group>3435</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>701</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>23510</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12403</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>5</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12482</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>17204</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>4</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11900</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>17</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10079</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>4</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6850</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>7</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>60</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>23511</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>9</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>7319</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>4</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12364</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>9</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>22803</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>17203</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12363</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>4</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Überspannungsschutzgerät DIN EN 61643-11 (VDE 0675-6-11), Typ 1 und 2, mit integrierter Überstromschutzeinrichtung, Einbauort am oder in der Nähe des Speisepunktes der elektrischen Anlage, Komplettbauweise, als Reiheneinbaugerät, Maße DIN 43880, mit Funktionsanzeige, Bemessungsbetriebsspannung 230/400 V AC, für TN-S-System mit Schutzschaltung DIN VDE 0100-534, Blitzstoßstrom (10/350) mind. 7,5 kA je Pol, Blitzstoßstrom (10/350) zwischen N und PE mind. 100 kA, Folgestromlöschfähigkeit mind. 25 kA effektiv, Schutzpegel max. 1,5 kV.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Überspannungsschutzgerät Typ 1/2 Reiheneinbau 230/400VAC TN-S-System 7,5kA je Pol 100kA N-PE Schutzpegel 1,5kV</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description><SumDescr>Yes</SumDescr><SubDescr><SubDNo>1</SubDNo><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Incl. Klemmen und Verdrahtungsmaterial so wie Arbeitslohn, zum Nachrüsten/Umrüsten von einzelnen Stromkreisen in Verteilungen.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Incl. Klemmen und Verdrahtungsmaterial so wie Arbeitslohn, zum Nachrüs</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></SubDescr></Item><Item ID="ID_549" RNoPart="0007"><Qty>4.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>054</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>054</WCtg><Group>3444</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>339</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12482</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12472</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>7</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12468</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12481</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10554</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>62</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11899</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12438</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6578</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>12</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12469</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5740</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>12</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Sicherungslasttrennschalter DIN EN IEC 60947-3 (VDE 0660-107), als Reiheneinbaugerät, Maße DIN 43880, einschl. Passeinsatz, bedingter Bemessungskurzschlussstrom 50 kA, fingersicher DIN EN 50274 (VDE 0660-514), zur Montage auf Tragschiene DIN EN 60715 (VDE 0660-520), Baugröße D 02, Bemessungsbetriebsspannung 400 V AC, Gebrauchskategorie AC-22, 3-polig, mit Sicherungseinsatz, Bemessungsstrom 63 A.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Sicherungslasttrennschalter Gr.D02 400VAC AC-22 3polig Sicherungseinsatz 63A</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_550" RNoPart="0008"><Qty>7.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>054</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>054</WCtg><Group>3444</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>339</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12482</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12472</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>7</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12468</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12481</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10554</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>62</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11899</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12438</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6578</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>12</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12469</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5740</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>54</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Sicherungslasttrennschalter DIN EN IEC 60947-3 (VDE 0660-107), als Reiheneinbaugerät, Maße DIN 43880, einschl. Passeinsatz, bedingter Bemessungskurzschlussstrom 50 kA, fingersicher DIN EN 50274 (VDE 0660-514), zur Montage auf Tragschiene DIN EN 60715 (VDE 0660-520), Baugröße D 02, Bemessungsbetriebsspannung 400 V AC, Gebrauchskategorie AC-22, 3-polig, mit Sicherungseinsatz, Bemessungsstrom 50 A.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Sicherungslasttrennschalter Gr.D02 400VAC AC-22 3polig Sicherungseinsatz 50A</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_551" RNoPart="0009"><Qty>5.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>054</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>054</WCtg><Group>3444</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>339</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12482</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12472</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>7</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12468</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12481</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10554</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>62</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11899</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12438</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6578</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>12</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12469</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5740</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>55</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Sicherungslasttrennschalter DIN EN IEC 60947-3 (VDE 0660-107), als Reiheneinbaugerät, Maße DIN 43880, einschl. Passeinsatz, bedingter Bemessungskurzschlussstrom 50 kA, fingersicher DIN EN 50274 (VDE 0660-514), zur Montage auf Tragschiene DIN EN 60715 (VDE 0660-520), Baugröße D 02, Bemessungsbetriebsspannung 400 V AC, Gebrauchskategorie AC-22, 3-polig, mit Sicherungseinsatz, Bemessungsstrom 35 A.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Sicherungslasttrennschalter Gr.D02 400VAC AC-22 3polig Sicherungseinsatz 35A</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_552" RNoPart="0010"><Qty>1.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>054</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>054</WCtg><Group>3444</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>339</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12482</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12472</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>7</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12468</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12481</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10554</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>62</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11899</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12438</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6578</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>12</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12469</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5740</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Sicherungslasttrennschalter DIN EN IEC 60947-3 (VDE 0660-107), als Reiheneinbaugerät, Maße DIN 43880, einschl. Passeinsatz, bedingter Bemessungskurzschlussstrom 50 kA, fingersicher DIN EN 50274 (VDE 0660-514), zur Montage auf Tragschiene DIN EN 60715 (VDE 0660-520), Baugröße D 02, Bemessungsbetriebsspannung 400 V AC, Gebrauchskategorie AC-22, 3-polig, mit Sicherungseinsatz, Bemessungsstrom 25 A.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Sicherungslasttrennschalter Gr.D02 400VAC AC-22 3polig Sicherungseinsatz 25A</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_553" RNoPart="0011"><Qty>1.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>054</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>054</WCtg><Group>3444</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>339</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12482</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12472</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>7</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12468</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12481</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10554</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>62</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11899</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12438</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6578</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>12</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12469</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5740</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Sicherungslasttrennschalter DIN EN IEC 60947-3 (VDE 0660-107), als Reiheneinbaugerät, Maße DIN 43880, einschl. Passeinsatz, bedingter Bemessungskurzschlussstrom 50 kA, fingersicher DIN EN 50274 (VDE 0660-514), zur Montage auf Tragschiene DIN EN 60715 (VDE 0660-520), Baugröße D 02, Bemessungsbetriebsspannung 400 V AC, Gebrauchskategorie AC-22, 3-polig, mit Sicherungseinsatz, Bemessungsstrom 25 A.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Sicherungslasttrennschalter Gr.D02 400VAC AC-22 3polig Sicherungseinsatz 25A</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_554" RNoPart="0012"><Qty>1.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>054</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>054</WCtg><Group>3444</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>339</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12482</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12472</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>7</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12468</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12481</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10554</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>62</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11899</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12438</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6578</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>12</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12469</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5740</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>9</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Sicherungslasttrennschalter DIN EN IEC 60947-3 (VDE 0660-107), als Reiheneinbaugerät, Maße DIN 43880, einschl. Passeinsatz, bedingter Bemessungskurzschlussstrom 50 kA, fingersicher DIN EN 50274 (VDE 0660-514), zur Montage auf Tragschiene DIN EN 60715 (VDE 0660-520), Baugröße D 02, Bemessungsbetriebsspannung 400 V AC, Gebrauchskategorie AC-22, 3-polig, mit Sicherungseinsatz, Bemessungsstrom 16 A.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Sicherungslasttrennschalter Gr.D02 400VAC AC-22 3polig Sicherungseinsatz 16A</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_555" RNoPart="0013"><Qty>3.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>054</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>054</WCtg><Group>3444</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>339</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12482</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12472</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>7</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12468</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12481</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10554</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>62</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11899</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12438</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6578</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>12</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12469</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5740</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>8</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Sicherungslasttrennschalter DIN EN IEC 60947-3 (VDE 0660-107), als Reiheneinbaugerät, Maße DIN 43880, einschl. Passeinsatz, bedingter Bemessungskurzschlussstrom 50 kA, fingersicher DIN EN 50274 (VDE 0660-514), zur Montage auf Tragschiene DIN EN 60715 (VDE 0660-520), Baugröße D 02, Bemessungsbetriebsspannung 400 V AC, Gebrauchskategorie AC-22, 3-polig, mit Sicherungseinsatz, Bemessungsstrom 10 A.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Sicherungslasttrennschalter Gr.D02 400VAC AC-22 3polig Sicherungseinsatz 10A</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_556" RNoPart="0014"><Qty>14.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>054</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>054</WCtg><Group>3444</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>339</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12482</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12472</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>7</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12468</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12481</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10554</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>285</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11899</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12438</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6578</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12469</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5740</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>55</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Sicherungslasttrennschalter DIN EN IEC 60947-3 (VDE 0660-107), als Reiheneinbaugerät, Maße DIN 43880, einschl. Passeinsatz, bedingter Bemessungskurzschlussstrom 50 kA, fingersicher DIN EN 50274 (VDE 0660-514), zur Montage auf Sammelschiene, Baugröße D 02, Bemessungsbetriebsspannung 400 V AC, Gebrauchskategorie AC-22, einpolig, mit Sicherungseinsatz, Bemessungsstrom 35 A.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Sicherungslasttrennschalter Gr.D02 400VAC AC-22 einpolig Sicherungseinsatz 35A</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_557" RNoPart="0015"><Qty>1.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>054</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>054</WCtg><Group>3474</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>586</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12482</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12481</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>18957</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5767</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11898</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>4</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5740</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>12</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12473</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6578</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>16</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5797</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>4</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>18668</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5753</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5741</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>14870</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>9</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>13963</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>13964</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>4459</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>8358</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Fehlerstromschutzschalter mit Überstromschutz (RCBO) DIN EN 61009-1 (VDE 0664-20), als Reiheneinbaugerät, Maße DIN 43880, fingersicher DIN EN 50274 (VDE 0660-514), Typ A pulsstromsensitiv, Auslösung unverzögert, Auslösecharakteristik B, DIN EN 60898-1 (VDE 0641-11), Bemessungsstrom 63 A, Bemessungsfehlerstrom 30 mA, 3-polig + N, 400 V AC, Kurzschlussfestigkeit 10 kA, stoßstromfest bis 250 A, mit Handbetätigung.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Fehlerstromschutzschalter RCBO TypA unverzögert Charakter.B 63A Fehlerstrom 30mA 3polig+N 400VAC</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_558" RNoPart="0016"><Qty>12.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>054</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>054</WCtg><Group>3474</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>586</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12482</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12481</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>18957</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5767</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11898</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>4</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5740</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12473</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6578</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>16</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5797</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>4</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>18668</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5753</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5741</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>14870</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>9</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>13963</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>13964</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>4459</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>8358</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Fehlerstromschutzschalter mit Überstromschutz (RCBO) DIN EN 61009-1 (VDE 0664-20), als Reiheneinbaugerät, Maße DIN 43880, fingersicher DIN EN 50274 (VDE 0660-514), Typ A pulsstromsensitiv, Auslösung unverzögert, Auslösecharakteristik B, DIN EN 60898-1 (VDE 0641-11), Bemessungsstrom 40 A, Bemessungsfehlerstrom 30 mA, 3-polig + N, 400 V AC, Kurzschlussfestigkeit 10 kA, stoßstromfest bis 250 A, mit Handbetätigung.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Fehlerstromschutzschalter RCBO TypA unverzögert Charakter.B 40A Fehlerstrom 30mA 3polig+N 400VAC</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_559" RNoPart="0017"><Qty>2.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>054</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>054</WCtg><Group>3462</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>344</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12482</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12481</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>60</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12479</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>7</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6516</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>61</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6578</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>12</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5741</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12450</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12447</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11898</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>4</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5740</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>32</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>8358</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Leitungsschutzschalter DIN EN 60898-1 (VDE 0641-11), als Reiheneinbaugerät, Maße DIN 43880, fingersicher DIN EN 50274 (VDE 0660-514),</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Bemessungsbetriebsspannung 230/400 V AC, Bemessungsausschaltvermögen 10 kA, mit beidseitiger Klemmenabdeckung, 3-polig, Auslösecharakteristik B, Bemessungsstrom 32 A.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Leitungsschutzschalter 230/400VAC Ausschaltvermögen 10kA 3polig Charakter.B 32A</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_560" RNoPart="0018"><Qty>2.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>054</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>054</WCtg><Group>3462</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>344</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12482</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12481</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>60</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12479</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>7</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6516</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>61</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6578</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>12</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5741</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12450</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12447</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11898</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>4</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5740</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>8358</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Leitungsschutzschalter DIN EN 60898-1 (VDE 0641-11), als Reiheneinbaugerät, Maße DIN 43880, fingersicher DIN EN 50274 (VDE 0660-514),</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Bemessungsbetriebsspannung 230/400 V AC, Bemessungsausschaltvermögen 10 kA, mit beidseitiger Klemmenabdeckung, 3-polig, Auslösecharakteristik B, Bemessungsstrom 25 A.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Leitungsschutzschalter 230/400VAC Ausschaltvermögen 10kA 3polig Charakter.B 25A</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_561" RNoPart="0019"><Qty>2.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>054</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>054</WCtg><Group>3462</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>344</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12482</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12481</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>60</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12479</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>7</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6516</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>61</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6578</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>12</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5741</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12450</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12447</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11898</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>4</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5740</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>9</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>8358</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Leitungsschutzschalter DIN EN 60898-1 (VDE 0641-11), als Reiheneinbaugerät, Maße DIN 43880, fingersicher DIN EN 50274 (VDE 0660-514),</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Bemessungsbetriebsspannung 230/400 V AC, Bemessungsausschaltvermögen 10 kA, mit beidseitiger Klemmenabdeckung, 3-polig, Auslösecharakteristik B, Bemessungsstrom 16 A.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Leitungsschutzschalter 230/400VAC Ausschaltvermögen 10kA 3polig Charakter.B 16A</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_562" RNoPart="0020"><Qty>1.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>054</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>054</WCtg><Group>3462</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>344</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12482</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12481</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>60</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12479</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>7</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6516</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>61</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6578</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5741</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12450</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12447</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11898</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5740</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>56</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>8358</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Leitungsschutzschalter DIN EN 60898-1 (VDE 0641-11), als Reiheneinbaugerät, Maße DIN 43880, fingersicher DIN EN 50274 (VDE 0660-514),</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Bemessungsbetriebsspannung 230/400 V AC, Bemessungsausschaltvermögen 10 kA, mit beidseitiger Klemmenabdeckung, einpolig, Auslösecharakteristik C, Bemessungsstrom 20 A.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Leitungsschutzschalter 230/400VAC Ausschaltvermögen 10kA einpolig Charakter.C 20A</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_563" RNoPart="0021"><Qty>1.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>054</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>054</WCtg><Group>3462</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>344</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12482</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12481</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>60</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12479</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>7</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6516</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>61</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6578</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5741</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12450</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12447</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11898</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5740</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>8</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>8358</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Leitungsschutzschalter DIN EN 60898-1 (VDE 0641-11), als Reiheneinbaugerät, Maße DIN 43880, fingersicher DIN EN 50274 (VDE 0660-514),</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Bemessungsbetriebsspannung 230/400 V AC, Bemessungsausschaltvermögen 10 kA, mit beidseitiger Klemmenabdeckung, einpolig, Auslösecharakteristik C, Bemessungsstrom 10 A.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Leitungsschutzschalter 230/400VAC Ausschaltvermögen 10kA einpolig Charakter.C 10A</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_564" RNoPart="0022"><Qty>50.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>054</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>054</WCtg><Group>3462</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>344</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12482</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12481</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>60</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12479</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>7</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6516</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>61</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6578</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5741</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12450</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12447</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11898</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>4</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5740</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>9</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>8358</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Leitungsschutzschalter DIN EN 60898-1 (VDE 0641-11), als Reiheneinbaugerät, Maße DIN 43880, fingersicher DIN EN 50274 (VDE 0660-514),</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Bemessungsbetriebsspannung 230/400 V AC, Bemessungsausschaltvermögen 10 kA, mit beidseitiger Klemmenabdeckung, einpolig, Auslösecharakteristik B, Bemessungsstrom 16 A.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Leitungsschutzschalter 230/400VAC Ausschaltvermögen 10kA einpolig Charakter.B 16A</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_565" RNoPart="0023"><Qty>3.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>054</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>054</WCtg><Group>8510</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>734</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12468</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12481</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12438</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11899</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>19</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12465</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6578</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>12</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10554</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>285</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>21154</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6459</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>280</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12469</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>9</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5740</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>13</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12480</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>30</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6492</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">NH-Sicherungslasttrennschalter in Trennerbauform DIN EN IEC 60947-3 (VDE 0660-107), bedingter Bemessungskurzschlussstrom 100 kA, fingersicher DIN EN 50274 (VDE 0660-514), Bemessungsbetriebsspannung 400 V AC, Gebrauchskategorie AC-22, Baugröße 1, Einfachunterbrechung, 3-polig, zur Montage auf Sammelschiene, Schienenmittenabstand 60 mm, mit Schraubanschluss, mit NH-Sicherungseinsatz, Bemessungsstrom 100 A, mit Sicherungsüberwachung.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>NH-Sicherungslasttrennschalter TrennerBF 400VAC AC-22 Gr.1 3polig NH-Sicherungseinsatz 100A</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_566" RNoPart="0024"><Qty>5.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>054</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>054</WCtg><Group>8510</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>734</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12468</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12481</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6842</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12438</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11899</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>19</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12465</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6578</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>12</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10554</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>285</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>21154</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6459</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>280</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12469</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>9</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5740</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>52</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>12480</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>30</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6492</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19904</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">NH-Sicherungslasttrennschalter in Trennerbauform DIN EN IEC 60947-3 (VDE 0660-107), bedingter Bemessungskurzschlussstrom 100 kA, fingersicher DIN EN 50274 (VDE 0660-514), Bemessungsbetriebsspannung 400 V AC, Gebrauchskategorie AC-22, Baugröße 1, Einfachunterbrechung, 3-polig, zur Montage auf Sammelschiene, Schienenmittenabstand 60 mm, mit Schraubanschluss, mit NH-Sicherungseinsatz, Bemessungsstrom 125 A, mit Sicherungsüberwachung.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>NH-Sicherungslasttrennschalter TrennerBF 400VAC AC-22 Gr.1 3polig NH-Sicherungseinsatz 125A</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_567" RNoPart="0025"><Qty>1.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Abstimmung mit dem EVU</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Abstimmung mit dem EVU</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_568" RNoPart="0026"><Qty>1.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Demontage der alten NSHV+UV+Zählerschrank.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Abgabe des Zählers an das EVU</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">inkl. Abklemmen, Demontage, Abtransport und</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Fachgerechter Entsorgung</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Demontage der alten NSHV+UV+Zählerschrank</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item></Itemlist></BoQBody></BoQCtgy><BoQCtgy ID="OID_79" RNoPart="02"><LblTx><span>Niederspannungsinstallationsanlagen</span></LblTx><BoQBody><Itemlist><Item ID="ID_569" RNoPart="0001"><Qty>50.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>053</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>053</WCtg><Group>5393</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>13252</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5812</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>29</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5813</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>135</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5814</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>238</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5811</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5686</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>28</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10617</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Installationsleitung DIN VDE 0250-204 (VDE 0250-204) NYM-J 3 x 1,5, Cu-Zahl 43.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Installationsltg NYM-J 3x1,5</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description><SumDescr>Yes</SumDescr><SubDescr><SubDNo>1</SubDNo><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Mischpreis für verschiedene Verlegearten:</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- auf Kabelrinne/in Kanal (ca.25%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Sammelhaltern (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- unter Bügelschellen (ca. 5%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- unter Putz (ca.20%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- auf Rohfußboden (incl. Schutzrohr) (ca. 5%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Hohlwänden/Vorsatzschalen (ca.20%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- sonstige Verlegearten (ca.10%)</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Mischpreis für verschiedene Verlegearten:</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></SubDescr></Item><Item ID="ID_570" RNoPart="0002"><Qty>50.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>053</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>053</WCtg><Group>5393</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>13252</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5812</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>29</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5813</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>134</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5814</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>219</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5811</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5686</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>28</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10617</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Installationsleitung DIN VDE 0250-204 (VDE 0250-204) NYM-J 3 x 2,5, Cu-Zahl 72.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Installationsltg NYM-J 3x2,5</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description><SumDescr>Yes</SumDescr><SubDescr><SubDNo>1</SubDNo><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Mischpreis für verschiedene Verlegearten:</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- auf Kabelrinne/in Kanal (ca.25%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Sammelhaltern (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- unter Bügelschellen (ca. 5%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- unter Putz (ca.20%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- auf Rohfußboden (incl. Schutzrohr) (ca. 5%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Hohlwänden/Vorsatzschalen (ca.20%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- sonstige Verlegearten (ca.10%)</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Mischpreis für verschiedene Verlegearten:</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></SubDescr></Item><Item ID="ID_571" RNoPart="0003"><Qty>50.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>053</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-04</VersDate><WCtg>053</WCtg><Group>5393</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>13252</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5812</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>29</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5813</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>132</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5814</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>219</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5811</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5686</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>28</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10617</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Installationsleitung DIN VDE 0250-204 (VDE 0250-204) NYM-J 5 x 1,5, Cu-Zahl 72.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Installationsltg NYM-J 5x1,5</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description><SumDescr>Yes</SumDescr><SubDescr><SubDNo>1</SubDNo><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Mischpreis für verschiedene Verlegearten:</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- auf Kabelrinne/in Kanal (ca.25%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Sammelhaltern (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- unter Bügelschellen (ca. 5%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- unter Putz (ca.20%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- auf Rohfußboden (incl. Schutzrohr) (ca. 5%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Hohlwänden/Vorsatzschalen (ca.20%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- sonstige Verlegearten (ca.10%)</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Mischpreis für verschiedene Verlegearten:</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></SubDescr></Item><Item ID="ID_572" RNoPart="0004"><Qty>50.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>053</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-04</VersDate><WCtg>053</WCtg><Group>5393</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>13252</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5812</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>29</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5813</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>131</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5814</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>209</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5811</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5686</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>28</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10617</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Installationsleitung DIN VDE 0250-204 (VDE 0250-204) NYM-J 5 x 2,5, Cu-Zahl 120.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Installationsltg NYM-J 5x2,5</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description><SumDescr>Yes</SumDescr><SubDescr><SubDNo>1</SubDNo><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Mischpreis für verschiedene Verlegearten:</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- auf Kabelrinne/in Kanal (ca.25%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Sammelhaltern (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- unter Bügelschellen (ca. 5%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- unter Putz (ca.20%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- auf Rohfußboden (incl. Schutzrohr) (ca. 5%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Hohlwänden/Vorsatzschalen (ca.20%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- sonstige Verlegearten (ca.10%)</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Mischpreis für verschiedene Verlegearten:</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></SubDescr></Item><Item ID="ID_573" RNoPart="0005"><Qty>100.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>053</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2022-04</VersDate><WCtg>053</WCtg><Group>5393</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>13252</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5812</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>29</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5813</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>130</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5814</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>198</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5811</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5686</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>28</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10617</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Installationsleitung DIN VDE 0250-204 (VDE 0250-204) NYM-J 5 x 4, Cu-Zahl 192.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Installationsleitung NYM-J 5x4</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description><SumDescr>Yes</SumDescr><SubDescr><SubDNo>1</SubDNo><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Mischkalkulation für verschiedene Verlegearten:</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- auf Kabelrinne/in Kanal (ca.30%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Sammelhaltern (ca.40%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- unter Bügelschellen (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Rohr (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- sonstige Verlegearten (ca.10%)</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Mischkalkulation für verschiedene Verlegearten:</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></SubDescr></Item><Item ID="ID_574" RNoPart="0006"><Qty>100.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>053</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>053</WCtg><Group>5393</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>13252</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5812</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>29</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5813</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>129</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5814</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>186</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5811</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5686</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>28</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10617</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Installationsleitung DIN VDE 0250-204 (VDE 0250-204) NYM-J 5 x 6, Cu-Zahl 288.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Installationsltg NYM-J 5x6</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description><SumDescr>Yes</SumDescr><SubDescr><SubDNo>1</SubDNo><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Mischkalkulation für verschiedene Verlegearten:</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- auf Kabelrinne/in Kanal (ca.30%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Sammelhaltern (ca.40%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- unter Bügelschellen (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Rohr (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- sonstige Verlegearten (ca.10%)</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Mischkalkulation für verschiedene Verlegearten:</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></SubDescr></Item><Item ID="ID_575" RNoPart="0007"><Qty>100.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>053</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>053</WCtg><Group>5395</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>13252</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5812</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>39</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5813</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>210</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5814</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>186</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5811</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>19</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5686</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>28</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10617</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Kabel DIN VDE 0276-603 (VDE 0276-603) NYY-J 5 x 6 RE, Cu-Zahl 288.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Kabel NYY-J 5x6RE</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_576" RNoPart="0008"><Qty>100.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>053</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>053</WCtg><Group>5393</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>13252</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5812</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>29</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5813</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>128</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5814</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>165</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5811</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5686</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>28</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10617</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Installationsleitung DIN VDE 0250-204 (VDE 0250-204) NYM-J 5 x 10, Cu-Zahl 480.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Installationsltg NYM-J 5x10</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description><SumDescr>Yes</SumDescr><SubDescr><SubDNo>1</SubDNo><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Mischkalkulation für verschiedene Verlegearten:</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- auf Kabelrinne/in Kanal (ca.30%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Sammelhaltern (ca.40%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- unter Bügelschellen (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Rohr (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- sonstige Verlegearten (ca.10%)</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Mischkalkulation für verschiedene Verlegearten:</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></SubDescr></Item><Item ID="ID_577" RNoPart="0009"><Qty>100.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>053</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>053</WCtg><Group>5393</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>13252</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5812</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>29</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5813</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>127</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5814</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>153</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5811</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5686</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>28</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10617</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Installationsleitung DIN VDE 0250-204 (VDE 0250-204) NYM-J 5 x 16, Cu-Zahl 768.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Installationsltg NYM-J 5x16</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description><SumDescr>Yes</SumDescr><SubDescr><SubDNo>1</SubDNo><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Mischpreis für verschiedene Verlegearten:</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- auf Kabelrinne/in Kanal (ca.25%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Sammelhaltern (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- unter Bügelschellen (ca. 5%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- unter Putz (ca.20%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- auf Rohfußboden (incl. Schutzrohr) (ca. 5%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Hohlwänden/Vorsatzschalen (ca.20%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- sonstige Verlegearten (ca.10%)</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Mischpreis für verschiedene Verlegearten:</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></SubDescr></Item><Item ID="ID_578" RNoPart="0010"><Qty>10.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>053</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>053</WCtg><Group>5393</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>13252</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5812</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>29</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5813</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>126</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5814</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>138</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5811</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5686</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>28</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10617</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Installationsleitung DIN VDE 0250-204 (VDE 0250-204) NYM-J 5 x 25, Cu-Zahl 1200.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Installationsltg NYM-J 5x25</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description><SumDescr>Yes</SumDescr><SubDescr><SubDNo>1</SubDNo><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Mischkalkulation für verschiedene Verlegearten:</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- auf Kabelrinne/in Kanal (ca.30%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Sammelhaltern (ca.40%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- unter Bügelschellen (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Rohr (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- sonstige Verlegearten (ca.10%)</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Mischkalkulation für verschiedene Verlegearten:</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></SubDescr></Item><Item ID="ID_579" RNoPart="0011"><Qty>20.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>053</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>053</WCtg><Group>5395</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>13252</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5812</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>37</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5813</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>166</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5814</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>120</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5811</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>19</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5686</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>28</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10617</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Kabel DIN VDE 0276-603 (VDE 0276-603) NYCWY 4 x 70 SM/35, Cu-Zahl 3082.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Kabel NYCWY 4x70SM/35</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description><SumDescr>Yes</SumDescr><SubDescr><SubDNo>1</SubDNo><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Mischkalkulation für verschiedene Verlegearten:</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- auf Kabelrinne/in Kanal (ca.30%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Sammelhaltern (ca.40%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- unter Bügelschellen (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Rohr (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- sonstige Verlegearten (ca.10%)</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Mischkalkulation für verschiedene Verlegearten:</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></SubDescr></Item><Item ID="ID_580" RNoPart="0012"><Qty>50.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>061</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>061</WCtg><Group>824</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>5815</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>7</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5679</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>30</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5816</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>136</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5817</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>21</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10617</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>3805</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>32</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Installationskabel, symmetrisch, J-Y(St)Y, 4 x 2 x 0,8.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Installationskabel symmetrisch J-Y(St)Y 4x2x0,8</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description><SumDescr>Yes</SumDescr><SubDescr><SubDNo>1</SubDNo><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Mischpreis für verschiedene Verlegearten:</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- auf Kabelrinne/in Kanal (ca.25%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Sammelhaltern (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- unter Bügelschellen (ca. 5%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- unter Putz (ca.20%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- auf Rohfußboden (incl. Schutzrohr) (ca. 5%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Hohlwänden/Vorsatzschalen (ca.20%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- sonstige Verlegearten (ca.10%)</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Mischpreis für verschiedene Verlegearten:</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></SubDescr></Item><Item ID="ID_581" RNoPart="0013"><Qty>100.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>061</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>061</WCtg><Group>5039</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>3805</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>60</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5679</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>61</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>21299</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>21748</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>23870</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>23947</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>21570</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>4</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5816</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>488</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6872</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5817</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>21</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10617</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Datenkabel für den Horizontal- und Steigbereich DIN EN 50288-4-1 (VDE 0819-4-1), Kategorie 7 DIN EN 50173-1 (VDE 0800-173-1), geschirmt, Trennklasse d DIN EN 50174-2 (VDE 0800-174-2), für PoE, Typ 1, Leitungswiderstand 0,065 Ohm/m und Kabeldurchmesser 0,007 m DIN EN 50174-2 (VDE 0800-174-2), Link-Klasse F, DIN EN 50173-1 (VDE 0800-173-1), 4 x 2 x AWG 22.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Datenkabel Horizontal-Steigbereich Kat.7 geschirmt 4x2xAWG22</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description><SumDescr>Yes</SumDescr><SubDescr><SubDNo>1</SubDNo><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Mischpreis für verschiedene Verlegearten:</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- auf Kabelrinne/in Kanal (ca.30%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Sammelhaltern (ca.40%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- unter Bügelschellen (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Rohr (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- sonstige Verlegearten (ca.10%)</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Mischpreis für verschiedene Verlegearten:</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></SubDescr></Item><Item ID="ID_582" RNoPart="0014"><Qty>100.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die Leitung bis 16mm2 sind freizuschalten und mittels</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Verbinder und Schrumpfschlauch zu verlangern.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Einschlieslich aller dazugehorigen freischaltungen und</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">messungen.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Leitung bis 16mm²</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description><SumDescr>Yes</SumDescr><SubDescr><SubDNo>1</SubDNo><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die Leitungen sind einzeln von den Sicherungsautomaten abzuklemmen und mittels Verbinder und Schrumpfschlauch zu verlangern und auf die neue Verteilung aufzulegen.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Allgemeines zum abklemmen und Verlängern der Leitungen</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></SubDescr></Item><Item ID="ID_583" RNoPart="0015"><Qty>20.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die Leitung von 25mm2 bis 95mm2 sind freizuschalten und</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">mittels Verbinder und Schrumpfschlauch zu verlangern.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Einschlieslich aller dazugehorigen freischaltungen und</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">messungen.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Leitung von 25 mm² bis 95 mm²</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description><SumDescr>Yes</SumDescr><SubDescr><SubDNo>1</SubDNo><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die Leitungen sind einzeln von den Sicherungsautomaten abzuklemmen und mittels Verbinder und Schrumpfschlauch zu verlangern und auf die neue Verteilung aufzulegen.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Allgemeines zum abklemmen und Verlängern der Leitungen</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></SubDescr></Item><Item ID="ID_584" RNoPart="0016"><Qty>2.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Bestandsleitungen sind von der alten NSHV abzuklemmen und auf die neue NSHV aufzulegen</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Umschlussarbeiten der Bestandsleitungen</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_585" RNoPart="0017"><Qty>2.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Koordination der Umschaltarbeiten.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Der AN koordiniert selbstständig die Freischaltung/Umschaltung der alten NSHV auf die neue NSHV. Es sind selbstständig alle Vorkehrungen,Abstimmungen für die Freischaltung zwischen dem AN und Nutzer,</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Koordination der Umschaltungen</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_586" RNoPart="0018"><Qty>1.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>053</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>053</WCtg><Group>3268</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>175</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>13627</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11905</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>14</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>17644</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11850</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>8864</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>16</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11851</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11849</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Potentialausgleichsschiene DIN VDE 0618-1 (VDE 0618-1), aus verzinktem Stahl, mit Kunststoffabdeckung, mit Anschluss für 7 x 2,5 bis 25 mm2, ein Flachband bis 30 mm x 3,5 mm, und Massivrundleiter, Durchmesser 8 bis 10 mm.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Potentialausgleichsschiene Stahl verz 7x2,5-25mm2 Abdeck. 30x3,5mm</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_587" RNoPart="0019"><Qty>200.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>053</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>053</WCtg><Group>5393</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>13252</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5812</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>29</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5813</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>138</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5814</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>221</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5811</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5686</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>28</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10617</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Installationsleitung DIN VDE 0250-204 (VDE 0250-204) NYM-J 1 x 6, Cu-Zahl 58.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Installationsltg NYM-J 1x6</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description><SumDescr>Yes</SumDescr><SubDescr><SubDNo>1</SubDNo><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Mischpreis für verschiedene Verlegearten:</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- auf Kabelrinne/in Kanal (ca.30%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Sammelhaltern (ca.40%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- unter Bügelschellen (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Rohr (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- sonstige Verlegearten (ca.10%)</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Mischpreis für verschiedene Verlegearten:</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></SubDescr></Item><Item ID="ID_588" RNoPart="0020"><Qty>50.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>053</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>053</WCtg><Group>5393</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>13252</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5812</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>29</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5813</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>136</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5814</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>204</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5811</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5686</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>28</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10617</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Installationsleitung DIN VDE 0250-204 (VDE 0250-204) NYM-J 1 x 16, Cu-Zahl 154.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Installationsltg NYM-J 1x16</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description><SumDescr>Yes</SumDescr><SubDescr><SubDNo>1</SubDNo><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Mischpreis für verschiedene Verlegearten:</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- auf Kabelrinne/in Kanal (ca.30%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Sammelhaltern (ca.40%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- unter Bügelschellen (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- in Rohr (ca.10%)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">- sonstige Verlegearten (ca.10%)</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Mischpreis für verschiedene Verlegearten:</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></SubDescr></Item><Item ID="ID_589" RNoPart="0021"><Qty>5.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Erdung von Einrichtungsgegenständen und Konstruktionsteilen wie Kabelbühnen, Überspannungsschutz,etc. mittels Kabelschuh und Schraubverbindung</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Erdung von Einrichtungsgegenständen</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_590" RNoPart="0022"><Qty>20.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>053</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>053</WCtg><Group>3278</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>570</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6490</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>72</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19612</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>16</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19613</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>12</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11905</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>3054</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>124</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>8016</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>8</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2169</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>147</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>8255</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>229</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>145</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2753</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>26</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">C-Profilschiene, Breite 35 mm, Höhe 18 mm, gelocht, aus bandverzinktem Stahl DIN EN 10346, an der Wand aus Beton, befestigen mit bauaufsichtlich zugelassenen Dübeln, Einbau im Innenbereich.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>C-Profilschiene B 35mm H 18mm gelocht Stahl bandverz Wandbefestigung</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description><SumDescr>Yes</SumDescr><SubDescr><SubDNo>1</SubDNo><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">einschl. aller systembedingten Form- und Verbindungsstücke, aus bandverzinktem Stahl DIN EN 10346 inkl. Befestigungsmaterial.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Einschl. aller systembedingten Form und Verbindungsstücke inkl. Befest</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></SubDescr></Item><Item ID="ID_591" RNoPart="0023"><Qty>10.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>053</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>053</WCtg><Group>3278</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>623</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6490</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>72</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2163</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11895</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11894</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10462</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>6516</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11905</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>3054</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>124</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>8016</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>8</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11892</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11891</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2169</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>100</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2753</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>26</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Steigleiter als Kabelleiter, gelocht, Sprossenabstand 300 mm, mit einem Trennsteg, aus bandverzinktem Stahl DIN EN 10346, Seitenhöhe mind. 35 mm, Breite mind. 300 mm, Einbau im Innenbereich.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Steigleiter gelocht Stahl bandverz H 35mm B 300mm</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_592" RNoPart="0024"><Qty>30.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Hammerfuß-Bügelschelle, mit bandverzinkter Stahldruckwanne nach DIN EN 10346, Hammerfußbügel tauchfeuerverzinkt nach DIN EN ISO 1461, mit 16-17 mm Schlitzweite.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Durchmesser 34-50mm</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Bügelschelle 34-50mm</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_593" RNoPart="0025"><Qty>30.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Hammerfuß-Bügelschelle, mit bandverzinkter Stahldruckwanne nach DIN EN 10346, Hammerfußbügel tauchfeuerverzinkt nach DIN EN ISO 1461, mit 16-17 mm Schlitzweite.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Durchmesser 22-30mm</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Bügelschelle 22-30mm</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_594" RNoPart="0026"><Qty>50.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>053</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>053</WCtg><Group>3275</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>207</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11905</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11267</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9731</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>23127</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11271</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11272</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11910</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10617</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>29</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Elektroinstallationsrohr DIN EN 61386 (VDE 0605), Maße DIN EN 60423, aus PE-HD, Außendurchmesser 25 mm, Druckfestigkeit Klasse 1 - sehr leicht (125 N) DIN EN 61386-1 (VDE 0605-1), Klasse Schlagbeanspruchung 3 - mittel DIN EN 61386-1 (VDE 0605-1), max. Gebrauchstemperatur Klasse 1 (60 Grad C) DIN EN 61386-1 (VDE 0605-1), Verlegung offen, auf Putz, mit Abstandsschellen.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Elektroinstallationsrohr PE-HD AD 25mm AP Abstandsschellen</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_595" RNoPart="0027"><Qty>50.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>053</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>053</WCtg><Group>3275</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10435</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>207</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11905</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>11</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11267</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9731</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>14</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>23127</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11271</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11272</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>11910</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10617</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>29</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Elektroinstallationsrohr DIN EN 61386 (VDE 0605), Maße DIN EN 60423, aus PE-HD, Außendurchmesser 32 mm, Druckfestigkeit Klasse 1 - sehr leicht (125 N) DIN EN 61386-1 (VDE 0605-1), Klasse Schlagbeanspruchung 3 - mittel DIN EN 61386-1 (VDE 0605-1), max. Gebrauchstemperatur Klasse 1 (60 Grad C) DIN EN 61386-1 (VDE 0605-1), Verlegung offen, auf Putz, mit Abstandsschellen.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Elektroinstallationsrohr PE-HD AD 32mm AP Abstandsschellen</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_596" RNoPart="0028"><Qty>100.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Sammelhalterung für die allgemeine Anwendung mit Befestigungslöchern 6 mm Ø, geeignet für Wand- und Deckenmontagefür bis zu 20 Ltg.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Liefern und Montieren</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Sammelhater bis 20 Ltg. Kunststoff</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item></Itemlist></BoQBody></BoQCtgy><BoQCtgy ID="OID_80" RNoPart="03"><LblTx><span>Kernbohrungen/Stemmarbeiten</span></LblTx><BoQBody><Itemlist><Item ID="ID_597" RNoPart="0001"><Qty>4.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>084</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2025-10</VersDate><WCtg>084</WCtg><Group>6341</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>5852</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2501</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>14</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2439</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>85</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>783</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>16162</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>16160</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>3335</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5833</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>50</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5832</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5834</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>9</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5853</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19068</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>22</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2294</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>20</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>7881</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>9</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>1737</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>17</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19064</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>8304</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>142</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>1630</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>127</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>22233</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>1631</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>4</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10490</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>46</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>19741</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2710</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>3182</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>159</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>785</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>82</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>786</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>7736</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>35</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>3631</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>139</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Bohrung, senkrecht zur Untergrundfläche, Untergrundfläche waagerecht, aus Mauerwerk aus Kalksandstein, Bohrdurchmesser über 50 bis 100 mm, Bohrtiefe über 20 bis 25 cm, einschl. Lösen des Bohrkerns aus dem Gefüge, nicht schadstoffbelastet,</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Abfall ist nicht gefährlich, Zuordnung LAGA Z 0 (uneingeschränkter Einbau), Wichte des Abbruchstoffes DIN EN 1991-1-1 15 kN/m3, Arbeitshöhe bis 3,5 m über der Standfläche des hierfür erforderlichen Gerüstes,</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Geräteeinsatz ist möglich, max. Gesamtgewicht bis 5 t, Ausführung erschütterungsarm DIN 4150, lärmarm, Lärmpegel max. 80 dB(A), Ausführung innerhalb des Bauwerks, über Kopf,</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">aufgenommene Stoffe sammeln, ohne Zerkleinerung, im Behälter des AN lagern, Behältergröße über 0,5 bis 1 m3, auf LKW des AN laden, Mengenermittlung nach Aufmaß,</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">die Entsorgung wird gesondert vergütet, Ausführung gemäß Zeichnung.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Bohrung KS Durchm. 50-100mm T 20-25cm nicht schadstoffbelastet Geräteeinsatz mgl. Stoffe</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_598" RNoPart="0002"><Qty>2.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Herstellen von Wand oder Deckendurchbruch in Mauerwerk / Beton.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Maße (LxBxT) = 100 mm x 100 x 300 mm</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Herstellen von Wand - Deckendurchbruch 100x100x300mm</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_599" RNoPart="0003"><Qty>2.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Herstellen von Wand oder Deckendurchbruch in Mauerwerk / Beton.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Maße (LxBxT) = 100 mm x 100 x 300 mm</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Herstellen von Wand - Deckendurchbruch 200x300x300mm</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_600" RNoPart="0004"><Qty>80.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>047</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2022-04</VersDate><WCtg>047</WCtg><Group>1204</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>4201</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2163</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>108</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>7955</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>84</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2628</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>36</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>126</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10970</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2439</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>66</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>1282</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>20</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>828</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>4207</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>4208</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>4206</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>172</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>7</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Brandschutzabschottung an Kabel-/Leitungsanlagenals Mineralwolleplattenschott,Feuerwiderstandsklasse S 90 DIN 4102-9,mit allgemeinem bauaufsichtlichen Prüfzeugnis/allgemeiner bauaufsichtlicher Zulassung,eckiger Durchbruch,Querschnitt über 0,01 bis 0,02 m2,Baustoffklasse DIN 4102-1 A (nichtbrennbar), Schmelzpunkt größer gleich 1000 Grad C,im Gebäude,Wandaus Stahlbeton,Dicke 240 mm.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Brandschutzabschottung Leitungsanlagen MW-Pl.Schott S90 0,01-0,02m2 Gebäude Wand D 240mm</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_601" RNoPart="0005"><Qty>6.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>047</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2022-04</VersDate><WCtg>047</WCtg><Group>1204</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>4201</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2163</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>108</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>7955</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>84</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2628</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>36</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>126</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10970</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2439</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>66</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>1282</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>20</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>828</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>4207</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>4208</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>4</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>4206</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>172</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>7</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Brandschutzabschottung an Kabel-/Leitungsanlagenals Mineralwolleplattenschott,Feuerwiderstandsklasse S 90 DIN 4102-9,mit allgemeinem bauaufsichtlichen Prüfzeugnis/allgemeiner bauaufsichtlicher Zulassung,eckiger Durchbruch,Querschnitt über 0,02 bis 0,05 m2,Baustoffklasse DIN 4102-1 A (nichtbrennbar), Schmelzpunkt größer gleich 1000 Grad C,im Gebäude,Wandaus Stahlbeton,Dicke 240 mm.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Brandschutzabschottung Leitungsanlagen MW-Pl.Schott S90 0,02-0,05m2 Gebäude Wand D 240mm</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item></Itemlist></BoQBody></BoQCtgy><BoQCtgy ID="OID_81" RNoPart="04"><LblTx><span>Beleuchtung</span></LblTx><BoQBody><Itemlist><Item ID="ID_602" RNoPart="0001"><Qty>1.000</Qty><QU>psch</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>445000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Baubeleuchtung mittels Stecker und Kupplung hertsellen und nach Baufortschritt</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">versetzten. Einschließlich deren aller Wartungsarbeiten und</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Erstatzteile für die gesamteBauzeit.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Inkl. Klein - und Befestigungsmaterial.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Anzahl der Leuchten: 30</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Anzahl Schutzkontaktstecker 230V IP44: 30</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Anzahl Schutzkontaktkupplung 230V IP44: 30</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Technische Daten der Leuchte:</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Ausstrahlungscharakteristik: breit</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Ausstrahlungsgeometrie: symmetrisch</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Lichtstärkeverteilung: direkt</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Material Reflektor: PMMA-Abdeckung</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Optisches System: PMMA-Diffusor</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Blendungsbewertung nach UGR-Einstufung (EN 12464-1) &lt; 25.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Farbe Leuchtenkörper: lichtgrau, (RAL 7035)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Zulässige Umgebungstemperatur (ta): -20 °C - +35 °C.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Betriebsgerät: Mit elektronischem Betriebsgerät, schaltbar.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Mittlere Bemessungslebensdauer L80(t</span><span style="color:black;font-family:'Arial';font-size:10pt;vertical-align:sub">q</span><span style="color:black;font-family:'Arial';font-size:10pt;"> 25 °C) = 50.000 h.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Lichtquelle gemäß Ökodesign-Anforderungen austauschbar.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Bemessungslichtstrom: ca. 4000 lm</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Bemessungsleistung: ca. 28,00 W</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Leistungsfaktor λ &gt; 0,95,</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Lichtausbeute: ca. 142 lm/W</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Farbwiedergabeindex: R</span><span style="color:black;font-family:'Arial';font-size:10pt;vertical-align:sub">a</span><span style="color:black;font-family:'Arial';font-size:10pt;"> &gt; 80</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Lichtfarbe: neutralweiß</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Farbtemperatur: 4000 K</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Farborttoleranz (initial MacAdam) ≤ 3 SDCM,</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Maße ca. (L x B): 1257 mm x 102 mm, Leuchtenhöhe 91 mm.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Schutzklasse (DIN EN 61140): I</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Schutzart (DIN EN 60529): IP66</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Schutzart raumseitig: IP66</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Baubeleuchtung liefern und montieren</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_603" RNoPart="0002"><Qty>50.000</Qty><QU>m</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>053</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>445000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2022-04</VersDate><WCtg>053</WCtg><Group>5389</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>13252</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>6</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5812</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>22</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5813</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>93</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5814</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>219</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5811</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>13</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>5686</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>28</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10617</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>9122</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>10</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Gummischlauchleitung DIN EN 50525-2-21 (VDE 0285-525-2-21) H07RN-F 5 G 1,5, Cu-Zahl 72.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Gummischlauchleitung H07RN-F 5G1,5</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_604" RNoPart="0003"><Qty>50.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>445000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Die Leuchte ist zu demontieren und zu entsorgen.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Weiterhin ist anteilig das Leitungsnetz der Beleuchtung</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">zu demontieren.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Das Befestigungsmaterial (Schrauben, Gewindestab, Haken</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">etc.) ist ebenfalls zu entfernen.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Demontage einer Einzelleuchten Keller</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_605" RNoPart="0004"><Qty>50.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>445000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">LED-Feuchtraum-Anbauleuchte für Decken -/ Wandbefestigung inkl aller Systembedingter Befestigungssysteme für Decke -/ Wandbefestigung und anteilmäsig mit Kettenbefestigung. Für Feuchträume und überdachte Außenbereiche. Leuchtenkörper aus PC. Leuchtenkörper Farbe lichtgrau (RAL 7035). Mit Cliplos-Verschlusstechnik zur schutzartgerechten, einfachen Montage von Diffusor-Abdeckwanne und Leuchtenkörper nach dem Anschluss. Anschlussfertig inkl LED-Treiber liefern und montieren.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Technische Daten:</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Ausstrahlungscharakteristik: breit</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Ausstrahlungsgeometrie: symmetrisch</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Lichtstärkeverteilung: direkt</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Material Reflektor: PMMA-Abdeckung</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Optisches System: PMMA-Diffusor</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Blendungsbewertung nach UGR-Einstufung (EN 12464-1) &lt; 25.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Farbe Leuchtenkörper: lichtgrau, (RAL 7035)</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Zulässige Umgebungstemperatur (ta): -20 °C - +35 °C.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Betriebsgerät: Mit elektronischem Betriebsgerät, schaltbar.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Mittlere Bemessungslebensdauer L80(t</span><span style="color:black;font-family:'Arial';font-size:10pt;vertical-align:sub">q</span><span style="color:black;font-family:'Arial';font-size:10pt;"> 25 °C) = 50.000 h.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Lichtquelle gemäß Ökodesign-Anforderungen austauschbar.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Bemessungslichtstrom: ca. 4000 lm</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Bemessungsleistung: ca. 28,00 W</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Leistungsfaktor λ &gt; 0,95,</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Lichtausbeute: ca. 142 lm/W</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Farbwiedergabeindex: R</span><span style="color:black;font-family:'Arial';font-size:10pt;vertical-align:sub">a</span><span style="color:black;font-family:'Arial';font-size:10pt;"> &gt; 80</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Lichtfarbe: neutralweiß</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Farbtemperatur: 4000 K</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Farborttoleranz (initial MacAdam) ≤ 3 SDCM,</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Maße ca. (L x B): 1257 mm x 102 mm, Leuchtenhöhe 91 mm.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Schutzklasse (DIN EN 61140): I</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Schutzart (DIN EN 60529): IP66</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Schutzart raumseitig: IP66</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>LED-Feuchtraum-Anbauleuchte Keller</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_606" RNoPart="0005"><Qty>1.000</Qty><QU>psch</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>445000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Messung der Beleuchtungsstärke</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Messbericht zur Messung der Beleuchtung</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Erstellung des Messprotokolls uber den Nachweis der</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">vorhandenen Beleuchtungsstärken der Kellerbeleuchtung</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Inklusive der Erstellung der Dokumentation</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Messung der Beleuchtungsstärke Keller</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item></Itemlist></BoQBody></BoQCtgy><BoQCtgy ID="OID_82" RNoPart="05"><LblTx><span>Sonstiges</span></LblTx><BoQBody><Itemlist><Item ID="ID_607" RNoPart="0001"><Qty>1.000</Qty><QU>psch</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Erstellung der Montageplanung:</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Direkt nach Auftragsvergabe sind die erforderlichen</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Ausführungsunterlagen anzufordern und die technischen Details zur Erstellung der Montagepläne.. Montageplanung beinhaltet die Zählerverteilung sowie die Hauptverteilung.Die Liste ist mit Angaben über Anschlussleistungen, Kabeltyp und Kabelzugweg zu erstellen. Die Erstellung der Montageplanung erfolgt nach VOB/VDI 6026 Bl.1 Der Auftragnehmer hat bis spätestens 3</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Wochen nach Auftragsvergabe diese Unterlagen zur</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Prüfung per Email und 2-fach auf Papier der Fachbauleitung zu schicken.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Erstellung der Montageplanung</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_608" RNoPart="0002"><Qty>1.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>053</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2022-04</VersDate><WCtg>053</WCtg><Group>3248</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>11821</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>2</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>3114</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>29</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>7851</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>4</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>7727</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>19</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Prüfung der Anlage mit Bemessungsspannung bis 1000 V,mit Besichtigen, Erproben und Messen,einschl. Messprotokoll.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Prüfung 1000V</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_609" RNoPart="0003"><Qty>1.000</Qty><QU>St</QU><CtlgAssign><CtlgID>CAGJAFNI</CtlgID><CtlgCode>050</CtlgCode></CtlgAssign><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><STLBBau><STLBBauCtlg><CtlgName>STLB-Bau</CtlgName><VersDate>2022-04</VersDate><WCtg>050</WCtg><Group>8564</Group></STLBBauCtlg><STLBBauID><ArtChrIdent>10698</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>4</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>22668</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>3</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>10164</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>1</ChVIdent></STLBBauID><STLBBauID><ArtChrIdent>2136</ArtChrIdent><ArtChIdx>0</ArtChIdx><ChVIdent>15</ChVIdent></STLBBauID></STLBBau><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Messbericht DIN EN 62305-3 (VDE 0185-305-3).</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Messbericht</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_610" RNoPart="0004"><Qty>1.000</Qty><QU>psch</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Sachverstendigenabnahme ist zu koordinieren. Sämtliche Unterlagen die zur Abnahme relevant sind, sind bereitzustellen.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Sachverstendigenabnahme</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_611" RNoPart="0005"><Qty>1.000</Qty><QU>psch</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p style="text-align:justify;"><span style="color:black;font-family:'Arial';font-size:10pt;">Abnahmebegleitung  der   Elektrischen Anlagen, durch einen baurechtlich, staatlich anerkannten Sachverständigen gem. der TPrüfVo. Die Leistung umfasst die technische Klärung mit dem Sachverständigen, dem Ausschreibendem und dem Ausführendem bei einem gemeinsamen Ortstermin mit anschließender Freigabe der Planungsunterlagen vor Montagebeginn sowie der Prüfung der technischen Anlagen nach Fertigstellung vor Übergabe des Gebäudes an den Nutzer, einschl Prüfbericht aus dem hervorgeht, dass die Anlage gemäß den Auflagen des Bauscheines mängelfrei ist. Evtl. erforderliche Nachprüfungen, die der Auftragnehmer zu vertreten hat werden nicht besonders vergütet. Weitere Kosten, wie Reisekosten, Kosten für die Berichterstattung und den Einsatz von Meßgeräten sowie Hilfeleistung durch den Auftragnehmer entstehen nicht.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p style="text-align:justify;"><span style="color:black;font-family:'Arial';font-size:10pt;">Die eigentliche Beauftragung des Sachverständigten erfolgt bauseits und ist in den Kosten nicht mit einzukalkulieren.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Beistellen Personal Sachverständigenabnahme Elektr/BWA/Blitzschutz/SiBel</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_612" RNoPart="0006"><Qty>1.000</Qty><QU>psch</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p><span style="color:black;font-family:'Arial';font-size:10pt;">Erstelen einer Excel Liste, zur Dokumentation aller im Gebäude erstellten Schottungen, incl. Fabrikat, Typ, Zulassungsnummer Erstellungsdatum, genaue Ort bezeichnung.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Dokumentation Brandschutz</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="ID_613" RNoPart="0007"><Qty>1.000</Qty><QU>psch</QU><CtlgAssign><CtlgID>CAGHUSDG</CtlgID><CtlgCode>443000000</CtlgCode></CtlgAssign><Description><CompleteText><DetailTxt><Text><p style="text-align:justify;"><span style="color:black;font-family:'Arial';font-size:10pt;">Erstellung der Dokumentations- und Revisionsunterlagen nach den anerkannten Regeln der Technik. Die nachfolgend beschriebenen Unterlagen sind in vierfacher Ausfertigung in DIN A4 Ordner gegliedert, 2 Wochen vor den Inbetriebnahmen zu übergeben.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p style="text-align:justify;"><span style="color:black;font-family:'Arial';font-size:10pt;">Die Bestandsunterlagen sind in folgender Ausführung in den Ordnern mit Register abzugeben. Sie sind wie folgt zu gliedern:</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">1. Inhaltsverzeichnis</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">2. Zeichnungsverzeichnis</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">3. Anlagenbeschreibung</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">4. Ersatzteilaufstellung</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">5. Technische Berechnungen</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">6. Bestandzeichnungen nach DIN gefaltet, ein Satz</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">farbig nach DIN angelegt. Alle Bestandszeichnungen sind</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">deutlich mt der Aufschrift "Bestandplan", dem</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">Firmenstempel und der rechtsverbindlichen Unterschrift</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">mit Datum zu versehen. Mit der Unterschrift wird</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">bestätigt, dass die Darstellungen auf den Plänen der</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">wirklichen Ausführung entsprechen.</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">7. Behördliche Abnahmen, Einmeßprotokolle</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">8. Sämtliche Anlagenteile (Leitungen etc.) sind zu</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">beschriften</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">9. Datenträger (CD) mit allen Installationszeichnungen und zuvor genannten Bestandsunterlageninhalten</span></p><p><span style="color:black;font-family:'Arial';font-size:10pt;">10. Datenträger mit allen Programm- und Programmierdateien aller installierter Anlage.</span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p style="text-align:justify;"><span style="color:black;font-family:'Arial';font-size:10pt;">Dazu zählen unter anderem:</span></p><p style="text-align:justify;"><span style="color:black;font-family:'Arial';font-size:10pt;">- Auflistung aller Technischen Anlagen</span></p><p style="text-align:justify;"><span style="color:black;font-family:'Arial';font-size:10pt;">- Prüfbücher mit dem Ergebnis der vor der Inbetriebnahme</span></p><p style="text-align:justify;"><span style="color:black;font-family:'Arial';font-size:10pt;"> durchgeführten Abnahmeprüfungen</span></p><p style="text-align:justify;"><span style="color:black;font-family:'Arial';font-size:10pt;">- Betriebsanweisung, einschließlich Bedienungs- und Installation- sanleitung der Anlagenhersteller</span></p><p style="text-align:justify;"><span style="color:black;font-family:'Arial';font-size:10pt;">- Liste der Anlagen die einer Überwachungspflicht auf</span></p><p style="text-align:justify;"><span style="color:black;font-family:'Arial';font-size:10pt;"> Grund öffentlich rechtlicher Vorschriften unterliegen, einschließlich</span></p><p style="text-align:justify;"><span style="color:black;font-family:'Arial';font-size:10pt;"> der Vorgesehenen Prüftermine.</span></p><p style="text-align:justify;"><span style="color:black;font-family:'Arial';font-size:10pt;">- Bescheinigung gemäß DEGUV</span></p><p style="text-align:justify;"><span style="color:black;font-family:'Arial';font-size:10pt;">- Erstprüfung gemäß VDE 0100 Teil 600</span></p><p style="text-align:justify;"><span style="color:black;font-family:'Arial';font-size:10pt;">- Konformitätsbescheinigung</span></p><p style="text-align:justify;"><span style="color:black;font-family:'Arial';font-size:10pt;">- Beleuchtungsberechnung</span></p><p style="text-align:justify;"><span style="color:black;font-family:'Arial';font-size:10pt;">-</span></p><p style="text-align:justify;font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p><p style="font-family:'Arial';font-size:11pt;"><span style="font-family:'Arial';font-size:11pt;"></span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><span>Dokumentations- und Revisionsunterlagen</span></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item></Itemlist></BoQBody></BoQCtgy></BoQBody></BoQCtgy></BoQBody></BoQ></Award></GAEB>
