<?xml version="1.0" encoding="UTF-8"?>
<!-- GXML Toolbox V3.3 R20220330;  http://www.gaeb-toolbox.de/ 
 gtcConverter.dll used version 2021.06.24  -->
<GAEB xmlns="http://www.gaeb.de/GAEB_DA_XML/DA83/3.2">
 <GAEBInfo>
  <Version>3.2</Version>
  <VersDate>2013-10</VersDate>
  <Date>2026-07-03</Date>
  <Time>12:09:20</Time>
  <ProgSystem>SOFTTECH GmbH / GXML Toolbox V3.3 R20220330</ProgSystem>
  <ProgName>AVANTI pro 2022</ProgName>
  <Certific>Available</Certific>
 </GAEBInfo>
 <PrjInfo>
  <NamePrj>AUSSCHREIBUNG</NamePrj>
  <LblPrj>Kreishaus und Leitstelle Coesfeld</LblPrj>
  <Descrip>
   <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
   <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
  </Descrip>
  <Cur>EUR</Cur>
  <CurLbl>Euro</CurLbl>
  <UPFracDig>2</UPFracDig>
 </PrjInfo>
 <Award>
  <DP>83</DP>
  <AwardInfo>
   <BoQID>3EE2A3DA-359A-4B05-9B15-5ADF021745F8</BoQID>
   <Cur>EUR</Cur>
   <CurLbl>Euro</CurLbl>
   <WarrDur>0</WarrDur>
   <WarrUnit>Months</WarrUnit>
  </AwardInfo>
  <BoQ ID="ID_BoQ36">
   <BoQInfo>
    <Name>39-3</Name>
    <LblBoQ>Trockenbauarbeiten - Lamellendecke (ohne Baffeln)</LblBoQ>
    <Date>2025-09-02</Date>
    <OutlCompl>AllTxt</OutlCompl>
    <BoQBkdn>
     <Type>BoQLevel</Type>
     <LblBoQBkdn>Gewerk</LblBoQBkdn>
     <Length>2</Length>
     <Num>Yes</Num>
     <Alignment>left</Alignment>
    </BoQBkdn>
    <BoQBkdn>
     <Type>BoQLevel</Type>
     <LblBoQBkdn>Titel</LblBoQBkdn>
     <Length>2</Length>
     <Num>Yes</Num>
     <Alignment>left</Alignment>
    </BoQBkdn>
    <BoQBkdn>
     <Type>Item</Type>
     <LblBoQBkdn>Teilleistung</LblBoQBkdn>
     <Length>4</Length>
     <Num>Yes</Num>
     <Alignment>left</Alignment>
    </BoQBkdn>
    <BoQBkdn>
     <Type>Index</Type>
     <LblBoQBkdn>Index</LblBoQBkdn>
     <Length>1</Length>
     <Num>No</Num>
     <Alignment>left</Alignment>
    </BoQBkdn>
    <LblTime>Minuten</LblTime>
   </BoQInfo>
   <BoQBody>
    <Remark ID="ID_5012">
     <Description ID="C5FAA2A7-956A-483B-BAF9-2F7676AD63B1">
      <CompleteText>
       <DetailTxt>
        <Text textWidth="14.998cm">
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Baubeschreibung Erweiterung Kreishaus und Leitstelle Coesfeld VOB Teil C</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Allgemeine Technische Vertragsbedingungen für Bauleistungen (ATV)</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Allgemeine Regelungen für Bauarbeiten jeder Art - DIN 18299</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Hinweis:</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Die Ordnungsziffern der nachfolgenden Punkte entsprechen der VOB C, DIN18299. Ordnungsziffern der VOB C DIN 18299 die nicht aufgeführt sind, bedürfen bei der vorliegenden</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Leistungsbeschreibung keiner gesonderten Angaben.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Soweit in der Leistungsbeschreibung auf Technische Spezifikationen, z.B. nationale Normen, mit denen Europäische Normen umgesetzt werden, europäische technische Zulassungen, gemeinsame technische Spezifikationen, internationale Normen, Bezug genommen</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">wird, werden auch ohne den ausdrücklichen Zusatz: &#x22;oder gleichwertig&#x22;,</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">immer gleichwertige Technische Spezifikationen in Bezug genommen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-weight:bold;font-size:10pt;">0.1 Angaben zur Baustelle</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-weight:bold;font-size:10pt;">0.1.1</span>
          <span style="font-family:Arial;font-size:10pt;"> </span>
          <span style="font-family:Arial;font-style:italic;font-size:10pt;">Lage der Baustelle, Umgebungsbedingungen, Zufahrtsmöglichkeiten und Beschaffenheit der Zufahrt sowie etwaige Einschränkungen bei ihrer Benutzung.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Das Baugrundstück befindet sich in der Stadt Coesfeld im Kreis Coesfeld in Nordrhein-Westfalen. Südöstlich an das Baugrundstücks grenzt die Straße &#x22;Friedrich-Ebert-Straße&#x22; an. Mehrere öffentliche Gebäude grenzen im Westen und Süden an das Grundstück an. Hierunter mehrere Gebäude des Kreises Coesfeld sowie öffentliche Bauten. Auf dem Baugrundstück und unmittelbar nördlich des Baufeldes liegt das Kreishaus 1, welches im Zuge der Erweiterung des Kreishauses und der Leitstelle einen direkten Zugang in Form einer zweigeschossigen Verbindungsbrücke zum Neubau erhalten soll. Die Topografie des Baufeldes weist ein leichtes Gefälle zur im Nordwesten befindlichen Fegetasche auf.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <br/>
          <span style="font-family:Arial;font-size:10pt;">Das Baugrundstück befindet sich in einem Wasserschutzgebiet. Es gelten die Regelungen der Wasserschutzgebietsverordnung sowie der gesetzlichen und allgemeinen Anforderungen zum Boden- und Grundwasserschutz.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Im östlichen Teil des Baugrundstücks grenzt ein Helikopterlandeplatz (angrenzend zur Friedrich-Ebert-Straße) zur Grundstückszufahrt an. Während An- und Abflug sowie während der Standzeit des Helikopters ergeben sich bauliche Einschränkungen, die zu jeder Zeit über die entsprechende Dauer einzuhalten sind. Es dürfen zudem keine Gegenstände unbefestigt und lose verlegt in der Nähe des Helikopterlandeplatzes (angrenzend zur Friedrich-Ebert-Straße) ausgelegt oder abgestellt werden.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Südlich und westlich des Baufeldes grenzen mehrere Bäume, die erhalten bleiben müssen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Die Baugrube kann im Norden und Osten geböscht werden. Im Süden und Westen kommt ein Verbau zum Einsatz. Stell- und Lagerflächen für Container sind dem Baustelleneinrichtungsplan zu entnehmen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Baustellenzufahrt und Ausfahrt sind voneinander getrennt und erfolgen beide über die Straße „Friedrich-Ebert-Straße“ im Südosten des Baugrundstücks. Die Zuwegung im Norden am Kreishaus 1 dient ausschließlich der Nutzung für Anlieferungen für das Kreishaus 1 sowie zur Nutzung von Dienstwagen der Kreisverwaltung. Diese wird temporär während der Bauzeit auf 3,00m erweitert sowie asphaltiert, ist jedoch nicht als Baustellenzu- und ausfahrt zu benutzen. Bei Baustellenein- und ausfahrten sind die verkehrsrechtlichen Anforderungen und die örtlichen Gegebenheiten zu beachten.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Die Baustraße und Zuwegung westlich des Baufeldes dient als Feuerwehrzufahrt und muss zu allen Zeiten freigehalten werden.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Transportwege auf der öffentlichen Verkehrsfläche sind ständig freizuhalten und bei Bedarf (bei Verunreinigung durch den AN) mit einer Kehrmaschine zu reinigen. Kosten gehen zu Lasten des AN. Es ist davon auszugehen, dass je nach Witterung mind. einmal je Woche für die Dauer der Erdarbeiten gekehrt werden muss. Ausbesserungen von Transportbeschädigungen im Straßenbereich gehen zu Lasten des Auftragnehmers.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Die Baustellenein- und ausfahrt hat nach den verkehrsrechtlichen Anforderungen und den örtlichen Gegebenheit zu erfolgen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Als vorbereitende Maßnahme wird der Baubetriebshof Coesfeld die Zufahrt im Süden des Parkplatzes errichten und den vorhandenen Pflasterbelag an der südlichen Baustelleneinfahrt sowie an der südlich angrenzenden Baustraße zum Baufeld zum Schutz aller nachfolgenden Gewerke mit Schutzmatten abdecken.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Der Kranstandort ist im Baustelleneinrichtungsplan dargestellt. Bei einer Änderung des Kranstandortes ist zu beachten, dass der Helikopterlandeplatz angrenzend zur Friedrich-Ebert-Straße nicht im Schwenkbereich des Krans liegt. Änderungen des Kranstandortes müssen frühzeitig bekannt und mit der Bauleitung und dem AG abgestimmt werden. Es ist zu beachten, dass sich im Schwenkbereich des Kranes das Bestandsgebäude Kreishaus 1 mit einer Höhe von 16m vorfindet.  Es muss zwingend darauf geachtet werden, dass der Schwenkradius des Kranauslegers nicht mit der im Baustelleneinrichtungsplan markierten Flugsicherheitszone kollidiert.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Erforderliche Mobilkranstandorte für zeitlich begrenzte Einsätze sind in Abstimmung mit der Bauleitung festzulegen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Im südlichen Bereich des Baugeländes sind vom AN Containerstandflächen herzustellen. Nördlich und westlich des Baufeldes sind Lagerflächen für die Nutzung des eigenen Gewerkes herzustellen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-weight:bold;font-size:10pt;">0.1.2</span>
          <span style="font-family:Arial;font-size:10pt;"> </span>
          <span style="font-family:Arial;font-style:italic;font-size:10pt;">Besondere Belastungen aus Immissionen sowie besondere klimatische oder betriebliche Bedingungen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Die Baumaßnahme findet während des laufenden Betriebes im Kreishaus 1 statt..</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Ein Teilbereich des südlichen Parkplatzes soll während der Baumaßnahme weiterhin als Besucherparkfläche genutzt werden können.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Aufgrund dessen muss mit erhöhter Sorgfalt und Rücksicht gearbeitet werden.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-weight:bold;font-size:10pt;">0.1.3</span>
          <span style="font-family:Arial;font-weight:bold;font-style:italic;font-size:10pt;"> </span>
          <span style="font-family:Arial;font-style:italic;font-size:10pt;">Art und Lage der baulichen Anlagen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Ziel der baulichen Maßnahme ist der Neubau eines Erweiterungsbaus im Süden des Bestandsgebäudes Kreishaus 1 in Coesfeld. Der Neubau ist darauf ausgerichtet, im Erdgeschoss und 1. Obergeschoss zusätzliche Räumlichkeiten für die Verwaltung bereitzustellen. Hierzu zählen neue Büroflächen sowie Konferenzbereiche, die eine Optimierung der Arbeitsabläufe und die Steigerung der Effizienz zum Ziel haben.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Die oberen Etagen, das zweite und dritte Obergeschoss, sind für die Erweiterung der Leitstelle vorgesehen. Diese umfasst einen Krisenstabsraum, einen zweigeschossigen Leitstellenbetriebsraum, angrenzende Büroflächen sowie Ruheräume.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Lage der baulichen Anlagen:</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Siehe beigefügter Lage- und Baustelleneinrichtungsplan.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;text-decoration:underline;font-size:10pt;">Erweiterungsbau</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Der geplante Erweiterungsbau wird als viergeschossiges Gebäude ohne Unterkellerung in Massivbauweise realisiert, wobei Decken und Wände vorrangig in Stahlbetonbauweise errichtet und teilweise in Sichtbetonqualität ausgeführt werden. Insbesondere im Erdgeschoss wird an den Außenwänden verstärkt auf Stahlbetonstützen in Sichtbetonqualität zurückgegriffen. Ein zentrales Element des Gebäudes bildet der durch alle Geschosse reichende offene Lichthof, der für eine optimale Lichtführung sorgt. Zwei durchgehende Treppenhäuser an der Süd- und Nordseite des Erweiterungsbaus dienen als Flucht- und Rettungswege für alle Geschosse. Für die barrierefreie Erschließung aller Etagen wird zudem ein Aufzug im nördlichen Treppenhaus installiert.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Die administrativen Bereiche, inklusive aller Büro- und Konferenzräume, sind über einen zentralen Erschließungsflur, der den Lichthof umgibt, sowie entlang der Achsen B/C und D/E zugänglich gemacht. Eine barrierefreie Verbindungsbrücke, die im 1. und 2. Obergeschoss an den Neubau anschließt, ermöglicht einen direkten Übergang zum bestehenden Gebäudekomplex. Der Bereich der Leitstelle, lokalisiert im zweiten und dritten Obergeschoss, wird ebenfalls über einen um den Lichthof geführten Erschließungsflur zugänglich gemacht. Ruhe- und Aufenthaltsräume sind über die Fortführung des Flurs entlang der Achsen B/C und D/E erreichbar.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Die Fassadengestaltung des Erweiterungsbaus wird mittels einer vorgesetzten Mauerwerkschale realisiert, die durch den Einsatz von Betonfertigteilen in Sichtbetonqualität ergänzt wird. Diese Betonfertigteile dienen als horizontale und vertikale Lisenen und werden durch Betonfertigteile mit aufgesetzten Riemchen als Abschluss der Stürze ergänzt. Im Bereich der Fensteröffnungen ist die Mauerwerksschale um 6 cm nach innen versetzt, wodurch der Bereich des Sturzes als Abschlusskante des Versprungs fungiert. Die Farblichkeit des Klinkers des Bestandsbaus wird aufgenommen und im Neubau weitergeführt.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Gebäudedaten:</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;text-decoration:underline;font-size:10pt;">Erweiterungsbau</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">-Brutto Geschossfläche BGF: 3.370,63m²</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">-Brutto Rauminhalt BRI: 13.482,37m³</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">-Länge: ca. 39,15m</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">-Breite: ca. 21,60m</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">-Höhe ab OK Gelände Osten: ca. 15,55m</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">-Höhe ab OK Gelände Westen: ca. 16,03m</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">-Höhe ab UK Bodenplatte Osten: ca. 16,48m</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">-Höhe ab UK Bodenplatte Westen: ca. 17,68m</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">-OKFFB Erdgeschoss: </span>
          <span style="font-family:Arial;font-weight:bold;font-size:10pt;">±</span>
          <span style="font-family:Arial;font-size:10pt;"> 0,00m (ca. 82,15üNN)</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">-OK Fertiggelände: </span>
          <span style="font-family:Arial;font-weight:bold;font-size:10pt;">-</span>
          <span style="font-family:Arial;font-size:10pt;"> 0,02m (ca. 82,13üNN)</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">-Anzahl der Geschosse: 4 Vollgeschosse</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;text-decoration:underline;font-size:10pt;">Bestandsgebäude</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">-Länge: ca. 92,99m</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">-Breite: ca. 60,535m</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">-Höhe ab OK Gelände: ca. 16,60m</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">-OKFFB Erdgeschoss:</span>
          <span style="font-family:Arial;font-weight:bold;font-size:10pt;"> +</span>
          <span style="font-family:Arial;font-size:10pt;"> 1,11m (ca. 83,26üNN)</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">-Anzahl der Geschosse: 4 Vollgeschosse</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-weight:bold;font-size:10pt;">0.1.4</span>
          <span style="font-family:Arial;font-size:10pt;"> </span>
          <span style="font-family:Arial;font-style:italic;font-size:10pt;">Verkehrsverhältnisse auf der Baustelle, insbesondere Verkehrsbeschränkungen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Siehe Punkt 0.1.1</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Für die Versorgung und Belieferung der Baustelle, Material An- und Abtransporte, gem. beigefügtem Lage- und Baustelleneinrichtungsplan.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-weight:bold;font-size:10pt;">0.1.5</span>
          <span style="font-family:Arial;font-style:italic;font-size:10pt;"> Für den Verkehr freizuhaltende Flächen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Die Ein- und Ausgänge, Verkehrswege für Zu- und Abfahrten, sowie brandschutzrelevante Flächen (z.B. Feuerwehraufstellflächen, Flucht- und Rettungswege, Sammelpunkte, etc.) angrenzender Gebäude müssen ständig freigehalten werden. Die Zu- und Abfahrten zur öffentlichen Straße, die Feuerwehrzufahrt sowie der Fluchtweg vom Kreishaus 1 müssen ständig freigehalten werden.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-weight:bold;font-size:10pt;">0.1.6</span>
          <span style="font-family:Arial;font-style:italic;font-size:10pt;"> Art, Lage, Maße und Nutzbarkeit von Transporteinrichtungen und Transportwegen, z.B. Montageöffnungen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Transporteinrichtungen, insbesondere Förderanlagen stehen seitens des AG nicht zur Verfügung.</span>
          <span style="font-family:Arial;font-style:italic;font-size:10pt;"> </span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-weight:bold;font-size:10pt;">0.1.7</span>
          <span style="font-family:Arial;font-style:italic;font-size:10pt;"> Lage, Art, Anschlusswert und Bedingungen für das Überlassen von Anschlüssen für Wasser, Energie und Abwasser.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">a) Anschlüsse für Energie:</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">1.) Baustrom nach Abnahme der Rohbauarbeiten:</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Einrichtung, Vorhaltung und Räumen des Baustromanschlusses durch den AN Elektro.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Arial;font-size:10pt;">Erst nach funktionsfertiger Herstellung der neuen Baustromversorgung kann die Baustromversorgung durch den AN Rohbauarbeiten zurückgebaut werden.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">b) Anschlüsse für Wasser:</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">1.) Bauwasser während der Rohbauarbeiten:</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Einrichtung, Vorhaltung und Räumen des Bauwasseranschlusses durch den AN Rohbauarbeiten. 2 Wasserentnahmestellennotwendig (eine Entnahmestelle für Anschlüsse des Sanitärcontainers, eine Entnahmestelle für Bauwasser auf dem Gelände). Es ist auf Frostsicherheit aller Bereiche der Wasserleitungen zu achten.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Vergütung des Verbrauchs gemäß Vertragsbedingungen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">2.) Bauwasser im Zuge des Bauablaufs:</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Umbau, Vorhaltung und Räumen des Bauwasseranschlusses durch den AN Baustellenlogistik. </span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">c) Anschlüsse für Abwasser:</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Der Abwasseranschluss befindet sich im Bereich der südlichen</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Parkplatzfläche.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Anschluss, Vorhaltung und Räumen des</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Abwasseranschlusses von Geländeoberkante bis</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Sanitärconainer wird durch den AN Baustelleneinnrichtung zur Verfügung gestellt.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Es ist untersagt, Zement-, Gips- und Putzschlämmen in</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">die Kanalisation zu entsorgen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">0.1.8</span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;"> Lage und Ausmaß der dem Auftragnehmer für die Ausführung seiner Leistungen zur Benutzung oder Mitbenutzung überlassenen Flächen und Räume.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Siehe beigefügter Lage- und Baustelleneinrichtungsplan. </span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Der Platzbedarf und die Baustelleneinrichtung sind mit der Bauleitung vor Beginn der Arbeiten abzustimmen. Lagerflächen für Baumaterialien, Baustoffe usw. werden im Einvernehmen mit der örtlichen Bauleitung benannt. Nicht genehmigte Bautüren innerhalb der Gebäude werden zu Lasten des AN entfernt. </span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Das Umsetzen von Teilbereichen der Baustelleneinrichtung auf Verlangen der örtlichen Bauleitung ist einzukalkulieren. Dieser Aufforderung ist unverzüglich nachzukommen. </span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Bewachung und Verwahrung der Baubuden, Arbeitsgeräte usw. des AN oder seiner Erfüllungsgehilfen - auch während der Arbeitsruhe - ist ausschließlich Sache des AN.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Baustelleneinrichtung erfolgt nur auf den im Baustelleneinrichtungsplan ausgewiesenen Flächen, in Abstimmung mit der örtlichen Objektüberwachung.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">0.1.11</span>
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;"> </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">Besondere umweltrechtliche Vorschriften.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Das geltende Kreislaufwirtschafts- und Abfallgesetz ist lückenlos zu erfüllen. Landesabfallgesetze sowie Satzungen der öffentlich-rechtlichen Entsorgungsträger sind zu beachten. Verpackungs-, Restmaterialien und Baustellenabfälle sind gemäß der gesetzmäßig vorgeschriebenen Entsorgung zu beseitigen und sind Eigentum des AN.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">0.1.12</span>
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;"> </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">Besondere Vorgaben für die Entsorgung, z. B. besondere Beschränkungen für die Beseitigung von Abwasser und Abfall.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Beseitigung von Schutt, Abfall, Verpackungs- und Abdeckmaterial hat von jedem Auftragnehmer arbeitstäglich zu erfolgen. Die Möglichkeit der Containerstellung sowie deren Standorte sind mit der Bauleitung abzustimmen. Eine Lagerung von Abfällen und Schutt auf der Baustelle ist unzulässig.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Bei der Schuttbeseitigung sind die geltenden Vorschriften des Landes bzw. der Kommune zu beachten. Grundsätzlich sind Verpackungen und Transportpaletten gebührenfrei gemäß Abfallbeseitigungsgesetz vom AN von der Baustelle zu entfernen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">0.1.14</span>
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;"> </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">Art und Umfang des Schutzes von Bäumen, Pflanzenbeständen, Vegetationsflächen, Verkehrsflächen, Bauteilen, Bauwerken, Grenzsteinen und dergleichen im Bereich der Baustelle.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Zu erhaltende Bäume dürfen während der Bauzeit weder beschädigt, oder durch Erdarbeiten ausgetrocknet werden. Nicht unmittelbar vom Neubau betroffene, angrenzende und zu erhaltende Bauteile, wie Straßenbeläge und technische Anlagen etc. sind während der Ausführungen in ausreichendem Maße vor Beschädigungen zu schützen. </span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Beschädigungen werden über Beweissicherungsverfahren des AG dokumentiert.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">0.1.15</span>
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;"> </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">Art und Umfang der Regelung und Sicherung des öffentlichen Verkehrs.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Feuerwehrzufahrten der umliegenden Gebäude sind während der gesamten Bauzeit in ihrer Funktion zu erhalten. Der amtl. Lageplan mit eingetragenen Feuerwehraufstellflächen und Bewegungsflächen ist beigefügt.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Verunreinigungen oder Beschädigungen öffentlicher Verkehrsanlagen, müssen durch den Verursacher sofort gemeldet, beseitigt bzw. instandgesetzt werden. Kosten gehen zu Lasten des AN.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Es ist davon auszugehen, dass je nach Witterung für die Dauer der Erdarbeiten mind. einmal je Woche gekehrt werden muss. Besonders verkehrsbehindernde Maßnahmen (Lieferung Fertigteile), sind vorher mit dem Auftraggeber und der Bauleitung abzusprechen und zu koordinieren.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">0.1.17</span>
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;"> </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">Bekannte oder vermutete Hindernisse im Bereich der Baustelle, z. B. Leitungen, Kabel, Dräne, Kanäle, Bauwerksreste und, soweit bekannt, deren Eigentümer.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Im Bereich der Baustelle zur Bestandsfassade des Kreishaus 1 liegen noch in Betrieb befindliche Grundleitungen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">0.1.18</span>
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;"> </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">Bestätigung, dass die im jeweiligen Bundesland geltende Anforderungen zu Erkundungs- und gegebenenfalls Räumungsmaßnahmen hinsichtlich Kampfmitteln erfüllt wurden.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Der Nachweis der Kampfmittelfreiheit wird vom AG erbracht. </span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">0.1.19</span>
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;"> </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">Gemäß der Baustellenverordnung getroffene Maßnahmen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Der Auftraggeber hat zur Wahrnehmung seiner Pflichten aus der Baustellenverordnung einen Sicherheits- und Gesundheitsschutz-Koordinator (SiGeKo) beauftragt. Der SiGeKo stellt eine Baustellenordnung auf, deren Forderungen einzuhalten sind. Die Baustellenordnung wird Vertragsbestandteil. Der SiGeKo nimmt jederzeit Einfluß auf die sicherheits- und gesundheitstechnisch korrekte Abwicklung der Baustelle und führt unangekündigte Kontrollen vor Ort durch. Die Mängel werden der Bauleitung mittels Bericht angezeigt und sind umgehend durch den AN zu beseitigen. Der AN, einschließlich seiner etwaigen Nachunternehmer, werden darauf hingewiesen, dass sie die für die Koordination der sicherheits- und gesundheitsrelevanten Punkte nötigen Unterlagen rechtzeitig zur Verfügung zu stellen haben. Der AN hat seine Arbeiter anhand der Gefährdungsanalyse nachweislich zu unterweisen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Erforderliche Sicherheitseinrichtungen, die auch zum Schutz anderer auf der Baustelle verkehrender Personen zu dienen haben, darf der AN während oder nach Beendigung der eigenen Arbeiten nur mit ausdrücklicher Zustimmung der örtlichen Bauleitung entfernen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">0.1.20</span>
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;"> </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">Besondere Anordnungen, Vorschriften und Maßnahmen der Eigentümer (oder der anderen Weisungsberechtigten) von Leitungen, Kabeln, Dränen, Kanälen, Straßen, Wegen, Gewässern, Gleisen, Zäunen und dergleichen im Bereich der Baustelle.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Bauausführung erfolgt während der üblichen Arbeitszeiten (7:00 - 19:00 Uhr werktags). Die Ausführung von Arbeiten außerhalb der vorgenannten Arbeitszeiten bedarf der Zustimmung des AG. An Sonn- und Feiertagen ist vom AN eigenverantwortlich die Zustimmung der zuständigen Behörde einzuholen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Regelungen und Arbeitsschutzrichtlinien für das Personal von Fremdfirmen bei der Durchführung von Auftragsarbeiten auf dem Gelände sind einzuhalten.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">0.1.21</span>
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;"> </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">Art und Umfang von Schadstoffbelastungen, z.B. des Bodens, der Gewässer, der Luft, der Stoffe und Bauteile; vorliegende Fachgutachten oder dergleichen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Siehe Baugrund- und Gründungsgutachten. Baugrund- und Gründungsgutachten ist beigefügt.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">0.1.23</span>
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;"> </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">Arbeiten anderer Unternehmer auf der Baustelle.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Der Auftragnehmer ist verpflichtet, seine Arbeiten mit anderen am Bau tätigen Unternehmern so zu koordinieren, dass keine Unterbrechungen bzw. Behinderungen im Bauablauf eintreten. Daraus bedingte Erschwernisse sind in die Einheitspreise einzurechnen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">0.2 Angaben zur Ausführung</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">0.2.02</span>
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;"> </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">Besondere Erschwernisse während der Ausführung, z.B. Arbeiten in Räumen, in denen der Betrieb weiterläuft, Arbeiten im Bereich von Verkehrswegen oder bei außergewöhnlichen äußeren Einflüssen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Süd- und Westseite des Baufeldes befindet sich in direkter Lage zur vorgesehenen Zu- und Ausfahrt für Feuerwehr und Anlieferungsfahrzeuge.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">0.2.04</span>
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;"> </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">Art und Umfang von Leistungen zur Unfallverhütung und zum Gesundheitsschutz für Mitarbeiter anderer Unternehmer, z.B. trittsichere Abdeckungen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">-Trittsichere Abdeckungen von Deckendurchbrüchen</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">-Schutznetze und Schutzgeländer</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">-Sicherheitskennzeichnungen</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">-Sicherheitskoordinator</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">0.2.06</span>
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;"> </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">Besondere Anforderungen an die Baustelleneinrichtung und Entsorgungseinrichtung, z.B. Behälter für die getrennte Erfassung.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Baustelleneinrichtung sieht eine Feuerwehrzuwegung an der Süd- und Westseite des Baufelds vor und muss unter allen Umständen frei gehalten werden.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">0.2.08</span>
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;"> </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">Mitbenutzung fremder Gerüste, Hebezeuge, Aufzüge, Aufenthalts- und Lagerräume, Einrichtungen und dergleichen durch den Auftragnehmer.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;"> Es werden durch den AG bzw. das Gewerk Gerüstbauarbeiten entsprechende Gerüste o.  bereitgestellt, die durch den AN mitbenutzt werden können.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Der Abstand zwischen Rohbau (tragende Außenwand) und Gerüst inkl. Konsole beträgt maximal 36 cm.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Im Zuge der späteren Fassadenarbeiten sind die Fassadenfertigteile mithilfe eines</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Baukrans von oben zwischen Rohbau und Arbeitsgerüst einzulassen und anschließend</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">zu montieren.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">An allen Seiten der Fassade wird der Abstand durch den Einbau von Konsolen (30 cm) bis</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">zur Montage der Fassadenunterkonstruktion (Unterkonstruktion und Dämmung) minimiert.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">An Konsolen wird wandseitig Seitenschutz angebracht werden. Der Seitenschutz wird im</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Zuge des Rückbaus der Konsolen an die Innenseite des Gerüsts angebracht.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Angaben zum gestellten Fassadengerüst:</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Standgerüst, längenorientiert, Fassadengerüst DIN EN 12810-1,</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Lastklasse 4 (3 kN/m2), Breitenklasse SW09, Höhenklasse H 1,</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">mit wandseitiger Belagverbreiterung über 0,25 bis 0,33 m,</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Es ist davon auszugehen, dass bauseits keine technische Hilfsmittel zum vertikalen und horizontalen Transport von Materialien gestellt werden (z. B. mobile Lastenaufzüge, Personenaufzüge, etc.). Bauseitige Aufenthalts- und Lagerräume zur Mitbenutzung durch den AN stehen nicht zur Verfügung.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">0.2.13</span>
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;"> </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">Art und Umfang der vom Auftraggeber verlangten Eignungs- und Gütenachweise.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Prüfungen und Nachweise:</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Art und Umfang der Eignungs-, Güte- und Kontroll- und sonstigen Prüfungen, sowie der Nachweise über die Eignung der Bauprodukte richten sich nach den vertraglichen Bestimmungen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Durchführung dieser Prüfungen, sowie die Erbringung der Nachweise, gelten als Nebenleistung, soweit im Vertrag nichts anderes geregelt ist.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Soweit auf Grund von Rechts- und Verwaltungsvorschriften Prüfungen oder Abnahmen gefordert jedoch nicht Vertragsinhalt sind, hat der Auftragnehmer deren Durchführung in Abstimmung mit dem Auftraggeber zu veranlassen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Kosten für diese Leistungen werden dem Auftragnehmer gegen Originalrechnungen und Nachweise (Prüfzeugnisse, Bescheinigungen, Atteste, usw.) vom Auftraggeber gesondert erstattet.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Termine für die Durchführung von Prüfungen bzw. Abnahmen hat der Auftragnehmer so rechtzeitig festzulegen, dass im Bauablauf keineUnterbrechungen bzw. Behinderungen entstehen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;text-decoration:underline;font-size:10pt;">Bauprodukte (Baustoffe, und Bauteile, usw.):</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Angaben über zu benennende Bauprodukte sind im Leistungsverzeichnis, sofern abgefragt, vorzunehmen. Bauprodukte dürfen nur verwendet werden, wenn der Nachweis über deren Eignung gemäß DIN 18299 erbracht ist. Bei der Bauausführung sind die Herstellervorschriften zu beachten.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Für sämtliche Bauteile mit brandschutztechnischen Anforderungen sind die erforderlichen Prüfzeugnisse und bauaufsichtlichen Zulassungen vor der Ausführung vorzulegen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">0.2.16</span>
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;"> </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">Art, Anzahl, Menge oder Masse der Stoffe und Bauteile, die vom Auftraggeber beigestellt werden, sowie Art, genaue Bezeichnung des Ortes und Zeit ihrer Übergabe.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Bereitstellung von Stoffen oder Bauteilen seitens des Auftraggebers ist nicht vorgesehen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">0.2.17</span>
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;"> </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">In welchem Umfang der Auftraggeber Abladen, Lagern und Transport von Stoffen und Bauteilen übernimmt oder dafür dem Auftragnehmer Geräte oder Arbeitskräfte zur Verfügung stellt.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Das Abladen, Lagern und Transportieren von Stoffen und Bauteilen ist seitens des Auftraggebers nicht vorgesehen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">0.2.22</span>
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;"> </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">Abrechnung nach bestimmten Zeichnungen oder Tabellen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Abrechnung erfolgt grundsätzlich gemäß VOB. Sofern abzurechnende Bauteile nur auf durch den Auftragnehmer zu fertigenden Werkstatt- oder Detailausführungszeichnungen erkennbar sind, sind diese Unterlagen inkl. den erforderlichen Listen und oder Tabellen vor Ausführung der Leistung dem Bauherrn bzw. der Bauleitung vorzulegen und Rechnungsunterlagen nochmals beizulegen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;">Zusätzliche Angaben zur Ausführung über Ordnungsziffern</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;">der VOB C DIN 18299 hinaus</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;">0.2.23 </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">Grundlagen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">a) Maßgebend für die nachstehend ausgeschriebenen</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Leistungen und deren vertragsgemäße Ausführung sind neben</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">den beigefügten Unterlagen folgende nicht beigefügte</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Unterlagen:</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-size:10pt;">Die VOB gilt im Ganzen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">außerdem gelten:</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">- die anerkannten Regeln der Technik</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">- bauaufsichtlichen Zulassungen und Prüfzeugnisse</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">- Verarbeitungsvorschriften und Empfehlungen der Hersteller</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">- Unfallverhütungsvorschriften der Berufsgenossenschaften</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Maßgeblich ist die jeweils neueste gültige Fassung.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die dem Leistungsverzeichnis beiliegenden Pläne und Berechnungen gelten als zeichnerische bzw. rechnerische Beschreibung der auszuführenden Leistung. Gleiches gilt für die beiliegenden Gutachten. </span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Hinweise zum Bauablauf sind lediglich Hinweise zur Baudurchführung und haben keinen Anspruch auf Vollständigkeit. Der Bauablauf ist vom AN unter Berücksichtigung statischer und konstruktiver Zwangspunkte und Eckdaten der Bauzeit sowie den genannten Einschränkungen zu planen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Sofern in den einzelnen Leistungspositionen die Vorgänge „Herstellen“, „Liefern“, „Einbauen“ bzw. „Montage“ nicht gesondert beschrieben sind, gelten diese Vorgänge einschließlich aller dafür erforderlichen Leistungen als beschrieben und sind im Angebotspreis einzurechnen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Arbeiten Dritter zur Fertigstellung der Leistungen sind nicht vorgesehen, sofern dies in den Positionen nicht ausdrücklich beschrieben ist.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;">0.2.24</span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;"> Vertretung des AN an der Baustelle.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;"> </span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Für die Leistung aller Aufgaben ist der AN verpflichtet auf der</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Baustelle einen bevollmächtigten Vertreter zu benennen und zur Verfügung des AG, bzw. dessen Vertreter zu halten. Die Benennung des Bauführers hat spätestens eine Woche nach Auftragserteilung zu erfolgen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Der Bauführer darf nur aus wichtigem Grund ausgetauscht werden. Ein Wechsel des Bauführers ist rechtzeitig mit entsprechender Begründung anzumelden. Der Bauführer, dessen Vertreter, oder der Fachbauleiter müssen der deutschen Sprache in Wort und Schrift fließend mächtig sein.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Aus wichtigem Grund kann der AG den sofortigen Austausch fordern.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;">0.2.25</span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;"> Koordinationsgespräche / Baubesprechungen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Der Auftragnehmer hat für die Dauer seiner Leistung zu den Baubesprechungen, die der Auftraggeber regelmäßig durchführt, einen geeigneten bevollmächtigten Vertreter zu entsenden. Die Besprechungen finden jeweils 1x pro Woche zu einem festen Termin (=&#x22;Jour Fixe&#x22;) statt.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;">0.2.26</span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;"> Bauablauf.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Der Bauablauf erfolgt nach jeweils gültigem Bauzeitenplan des AG und den vertraglichen Vereinbarungen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;">0.2.27</span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;"> Bautagesberichte.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Der Auftragnehmer hat Bautagesberichte zu führen und diese der örtlichen Bauleitung täglich zu übergeben.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Diese müssen alle Angaben enthalten, die für die Ausführung und Abrechnung des Auftrages von Bedeutung sein können, aber mindestens Angaben über das Wetter, Temperatur, Zahl und Art der eingesetzten Großgeräte, Zahl der Arbeitskräfte, den wesentlichen Baufortschritt (mit Beginn und Ende von Leistungen grösseren Umfangs), Unfälle und sonstige besondere Vorkommnisse enthalten.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">In den Tagesberichten dürfen keine Angaben zu Behinderungen oder Stundenlohnarbeiten aufgenommen werden. Eventuelle Eintragungen diesbezüglich gelten als nicht geschrieben.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;">0.2.28</span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;"> Vom AG zur Verfügung gestellte Ausführungsunterlagen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die für die Bauausführung maßgeblichen Ausführungsunterlagen (Ausführungszeichnungen, Berechnung, Behördenbescheide usw.), werden dem</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">AN nach Auftragserteilung rechtzeitig vor Ausführung der jeweiligen Leistung - gegen Empfangsbestätigung - ausgehändigt.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Ausführungsunterlagen werden in digitaler Form (PDF) übermittelt. Abweichungen gegenüber diesen Unterlagen bedürfen der schriftlichen Beantragung des Auftragnehmers und der Zustimmung durch den Auftraggeber.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;">0.2.29</span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;"> Vom AN zu erbringenden Ausführungsunterlagen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Vom AN zu fertigende Unterlagen sind nach Abstimmung mit den vom AG bestellten Fachingenieuren ausschließlich in digitaler Form an den AG zur Prüfung und Freigabe vorzulegen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Art der Unterlagen sind gemäß VOB als Nebenleistung zu erbringen oder über die Nebenleistung hinausgehende Unterlagen in den Leistungspositionen gesondert gefordert.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Von den vorgelegten Unterlagen erhält der AN ein Exemplar mit Prüfvermerk zurück. Bei Korrekturen des AG ist die Vorlage nach Übernahme der Korrekturen zu wiederholen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Ausführungsunterlagen sind bei dem AG rechtzeitig, jedoch spätestens 18 Werktage vor der Ausführung einzureichen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Soweit in den Ausschreibungsunterlagen darauf hingewiesen, hat der AN erforderliche behördliche Genehmigungen, Prüfungen, notwendige Nachweise, sowie Zulassungen und Gestattungen rechtzeitig einzuholen und notwendige statische Berechnungen zu erstellen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;">0.2.30</span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;"> Bauzeitenplan des AN.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Der AN ist verpflichtet, nach Absprache mit der Bauleitung, zwei Wochen nach Auftragsvergabe, bei Überarbeitung unverzüglich, einen genauen Bauzeitenplan (Bauablaufplan als Balkenplan) für seine Leistungen unter Berücksichtigung der Terminvorgaben dem AG vorzulegen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Der Bauzeitenplan ist ausschließlich in digitaler Form vorzulegen. Die Bauleitung fertigt einen Gesamt-Bauzeitenplan, in welchem die vorgenannten Termine eingearbeitet werden.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Rahmen- und Zwischentermine werden damit verbindlich. Rahmen- und Zwischentermine, auch nach vereinbarten Verschiebungen, werden Vertragsfristen im Sinne der VOB.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Kosten für die Erstellung des Bauablaufplan sind in die</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Einheitspreise einzukalkulieren.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;">0.2.31 </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">Abnahmen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">In jedem Falle ist eine förmliche Abnahme nach Fertigstellung der gesamten geschuldeten Leistungen, einschl. Dokumentation, durchzuführen. Diese förmliche Abnahme wird nicht durch eine vorzeitige Benutzung, die Inbetriebnahme der Leistung, eine bauaufsichtliche oder sonstige behördliche Abnahme oder die Anweisung der Schlusszahlung etc. ersetzt.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Über die Abnahme wird ein Protokoll erstellt.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Wurde die förmliche Abnahme verweigert, ist nach</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Mängelbeseitigung eine erneute Abnahme zu beantragen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Mit dem schriftlichen Antrag auf erneute Abnahme hat der AN den Nachweis zu führen, dass die wesentlichen Mängel nicht mehr vorliegen.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;">0.2.32 </span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;">Projekt- und Dokumentenmanagementsystem</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;"> </span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Der Auftraggeber hat für die Kommunikation und Dokumentation mit dem Auftragnehmer und den weiteren Projektbeteiligten ein Projekt- und Dokumentenmanagementsystem eingerichtet.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;"> </span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Der Auftragnehmer hat das Projekt- und Dokumentenmanagementsystem zwingend zu nutzen. Das elektronische Projekt- und Dokumentenmanagementsystem verfügt über eine Dokumentenablage- und eine Kommunikationsfunktion. Der Auftragnehmer hat diese Funktionen zu verwenden. Der Unternehmer verpflichtet sich, Dokumente jeder Art uneingeschränkt und unverzüglich nach deren Erstellung in dem Projekt- und Dokumentenmanagementsystem abzulegen. Diese Dokumente gelten nur in dem Fall als zugestellt, wenn sie entsprechend den inhaltlichen Vorgaben in dem Projekt- und Dokumentenmanagementsystem so eingestellt worden sind, dass sie ohne weiteren Aufwand ermittelt werden können. Hierbei hat der Auftragnehmer zwingend die Vorgaben des Auftraggebers zur Benennung und Bezeichnung von Dokumenten und Planunterlagen einzuhalten. Mit der Ablage der Dokumente im Projekt- und Dokumentenmanagementsystem erhält der Auftraggeber das uneingeschränkte Recht, diese Dokumente zu nutzen. Im elektronischen Projekt- und Dokumentenmanagementsystem vom Auftraggeber abgelegte Dokumente gelten im umgekehrten Fall ebenfalls als zur Verfügung gestellt und als schriftlich zugestellt.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;"> </span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Nutzung des Systems ist für den Auftragnehmer kostenlos. Aufwendungen, die dem Auftragnehmer evtl. durch diese Anforderung entstehen, werden nicht gesondert vergütet.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;"> </span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Nach der Auftragserteilung ist vom Auftragnehmer eine Projekt-Mailadresse od. die Mail-Adresse des projektverantwortlichen Mitarbeiters anzugeben.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;"> </span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Nach der Auftragserteilung erfolgt eine Einweisung in die Bedienung des Systems.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;">0.5 Abrechnung</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-weight:bold;font-style:italic;font-size:10pt;">0.5.1</span>
          <span style="font-family:Frutiger45Light;font-style:italic;font-size:10pt;"> Abrechnungspläne.</span>
         </p>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
         <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
          <span style="font-family:Frutiger45Light;font-size:10pt;">Die Abrechnung erfolgt nach den vom AN zu erstellenden Abrechnungsplänen.</span>
         </p>
        </Text>
       </DetailTxt>
       <OutlineText>
        <OutlTxt>
         <TextOutlTxt>
          <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
           <span>Allgemeine Regelungen für Bauarbeiten jeder Art - DIN 18299</span>
          </p>
         </TextOutlTxt>
        </OutlTxt>
       </OutlineText>
      </CompleteText>
     </Description>
    </Remark>
    <BoQCtgy ID="ID_5013" RNoPart="01">
     <LblTx>
      <span>Allgemeines</span>
     </LblTx>
     <BoQBody>
      <BoQCtgy ID="ID_5014" RNoPart="01">
       <LblTx>
        <span>Allgemein</span>
       </LblTx>
       <BoQBody>
        <Itemlist>
         <Remark ID="ID_5830">
          <Description ID="EF33B84E-B86B-430D-B64D-405CD34DB5F9">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Ergänzungen zu</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Allgemeinen Regelungen für Bauarbeiten jeder Art, DIN 18299</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Hinweis:</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die Ordnungsziffern der nachfolgenden Punkte entsprechen der VOB C, DIN 18340. Ordnungsziffern der VOB C, DIN 18340 die nicht aufgeführt sind, bedürfen bei der vorliegenden Leistungsbeschreibung keiner gesonderten Angaben.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">0.1 Angaben zur Baustelle</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-style:italic;font-size:10pt;">Art, Lage, Maße und Ausbildung sowie Termine des Auf- und Abbaus von bauseitigen Gerüsten.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Bauseitige Gerüste für die Ausführungen der Trockenbauarbeiten werden nicht zur Verfügung gestellt.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Hebezeug steht nicht zur Verfügung.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">0.2 Angaben zur Ausführung</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">0.2.2 </span>
               <span style="font-family:Arial;font-style:italic;font-size:10pt;">Gestaltung und Einteilung von Flächen. Raster- und Fugenausbildung, besondere Verlegart.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Gestaltung der Deckenflächen gemäß Ausführungsplanung. Anschlüsse zwischen Decken und Wänden erfolgen grundsätzlich sofern nicht anders gefordert als starre Anschlüsse.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">0.2.3 </span>
               <span style="font-family:Arial;font-style:italic;font-size:10pt;">Maße, Sonderformate, Formen und Profile, z.B. Tafeln, Paneele, Kassetten, Oberflächenart, Struktur und Oberflächenbehandlung sowie Farben der Bauteile, Ausbildung der Kanten und Ecken.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Metall-Lamellendecke, mikroperforiert, mit Akustikvlies ausgekleidet. Steghöhe Lamelle: 40 mm, Stegbreite: 10 mm, Achsabstand: 50 mm</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Teilweise Ausführung mit zusätzlichen Dämmplatten und / oder Akustikabsorbern an Rohdecke</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">0.2.7 </span>
               <span style="font-family:Arial;font-style:italic;font-size:10pt;">Art und Ausbildung der Verankerung der Trag- und Unterkonstruktionen, z.B. Dübel, Schrauben.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abhänger Metall-Lamellendecken sind an Stahlbetondecken nach Wahl des AN bzw. Herstellervorgaben zu befestigen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">0.2.8 </span>
               <span style="font-family:Arial;font-style:italic;font-size:10pt;">Art, Beschaffenheit und Festigkeit des Untergrundes, z.B. verputztes oder unverputztes Mauerwerk, Beton, Porenbeton, Hohlkörper- oder Holzbalkendecke, Verbundestrich, Estrich auf Trenn- oder Dämmstoffschicht mit oder ohne Fußbodenheizung, Hohlboden, Doppelboden.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abgehängte Decken werden grundsätzlich an glatten Betondecken befestigt.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">0.2.13 </span>
               <span style="font-family:Arial;font-style:italic;font-size:10pt;">Vorleistungen anderer Unternehmer, insbesondere hinsichtlich der Ausführung der An- und Abschlüsse.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die haustechnischen Grobinstallationen sind zum Zeitpunkt der Leistungserbringung der Unterkonstruktion bauseits teilweise vorhanden. Im Zuge der Deckenbekleidungen werden die Fertiginstallationen der Haustechnik ausgeführt.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">0.2.15 </span>
               <span style="font-family:Arial;font-style:italic;font-size:10pt;">Anzahl, Art, Lage, Maße und Massen von Installations- und Einbauteilen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Im Bereich von abgehängten Decken ist insbesondere in Nebenräumen und Fluren eine erhöhte Installationsdichte vorhanden.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">0.2.21 </span>
               <span style="font-family:Arial;font-style:italic;font-size:10pt;">Anforderungen an den Brand-, Schall-, Wärme-, Feuchte- und Strahlenschutz sowie an die Luftdichtheit und elektrische Leitfähigkeit, akustische sowie licht- und lüftungstechnische Anforderungen, Feuerwiderstandsklasse, z.B. nach DIN 4102 (alle Teile) &#x22;Brandverhalten von Baustoffen und Bauteilen&#x22;.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die in den Leistungspositionen angegebenen Anforderungen an Schallschutz bzw. Raumakustik sind gemäß vorzulegenden Prüfzeugnissen nachzuweisen und einzuhalten.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">0.2.22 </span>
               <span style="font-family:Arial;font-style:italic;font-size:10pt;">Anzahl, Art, Lage, Maße und Ausbildung von Flächenheiz- und Kühlsystemen, z.B. Registermodulen, Verbindungen der Registermodule untereinander, Angaben zu Anschlüssen an das Verteilnetz.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Ausführung der Metall-Lamellendecken in Teilbereichen als Heiz-Kühl-Lamellensystem nach Herstellervorgaben.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">0.2.28 </span>
               <span style="font-family:Arial;font-style:italic;font-size:10pt;">Art und Umfang der vom Auftragnehmer zu liefernden Verlege- und Montagepläne, Stofflisten und sonstiger Dokumentationen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Für die Ausführung von Bauteilen mit definierten Anforderungen (z.B. Brandschutz und Schallschutz) sind vor der Ausführung die entsprechenden Nachweise des Herstellers vorzulegen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">0.2.31 </span>
               <span style="font-family:Arial;font-style:italic;font-size:10pt;">Anzahl, Art, Maße sowie Zeitpunkt der Montage von vorgezogenen oder nachträglich herzustellenden Teilflächen, z.B. Flächen hinter Installationen und Heizkörpern, Teilbeplankungen für Estrichverlegung.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die Arbeiten sind wegen zu integrierender Installationen (Elektro, Lüftung, usw.) in zwei unterschiedlich terminierten Arbeitsvorgängen zu erbringen.</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>ATV: für Trockenbauarbeiten (DIN 18340)</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Remark>
         <Remark ID="ID_5832">
          <Description ID="518D46E2-5B1C-4EC1-9871-815AE57636B5">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="20cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Arbeitsablauf</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die Erweiterung des Kreishaus 1 wird in einem Zuge ausgeführt.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Folgender Arbeitsablauf ist mit den Teilleistungen 1 bis 3 geplant:</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">1.) Montage von Dämmplatten und Akustikabsorbern an Rohdecke als Vorleistung der Metall-Lamellendecken bzw. parallel zu Installationsarbeiten in gesondertem Arbeitsabschnitt mit darauf folgender Arbeitsunterbrechung.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">2.) Montage Abhänger und Grundkonstruktion der abgehängten Lamellendecken als Vorleistung bzw. parallel zu Installationsarbeiten in gesondertem Arbeitsabschnitt mit darauf folgender Arbeitsunterbrechung.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">3.) Montage der Lamellen als Decklage von abgehängten Decken.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Für alle Arbeiten sind eigene Gerüste zu kalkulieren. </span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Ob sich Teilleistungen aufeinanderfolgend ausführen lassen, entscheidet der Baufortschritt der Installationsgewerke. Für die Kalkulation ist jedoch von getrennten Arbeitsgängen für die Teilleistungen auszugehen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Alle sich aus den Arbeitsabschnitten ergebenden Leistungen sind einzukalkulieren bzw. in den Leistungspositionen zu berücksichtigen.</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Arbeitsablauf</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Remark>
         <Remark ID="ID_5834">
          <Description ID="822382EC-6199-48AC-924A-CA830BF11FB6">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="20cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Baustelleneinrichtung</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Das Einrichten, Vorhalten und Räumen der Baustelle für sämtliche in der Leistungsbeschreibung aufgeführten Leistungen ist als Nebenleistung gemäß DIN 18299 zu erbringen und wird nicht gesondert vergütet.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die Art und der Umfang der Baustelleneinrichtung ( BE ) ist dem AN überlassen. </span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Zur Baustelleneinrichtung zählen insbesondere:</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">- Transport- und Hebeeinrichtungen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">- Material- und Werkzeugcontainer</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">- Aufenthaltscontainer, sofern erforderlich</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">- Einrichtungen für Abfallentsorgung ( z.B. Abfallcontainer )</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">- Lagerflächen für Materialien</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Aufenthalts- und Lagerraum sind nur als gestapelte Container ( untere Ebene Lagerraum, obere Ebene Aufenthalt ) an im Baustelleneinrichtungsplan dargestellten Standorten möglich.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die Art und Anzahl , maximal 2 Stück , der Container erfolgt nach Wahl bzw. den Bedürfnissen der ausführenden Firma und den gesetzlichen Vorschriften.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Das Liefern, Vorhalten und Räumen der Container ist in die Baustelleneinrichtung einzukalkulieren.</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Baustelleneinrichtung</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Remark>
         <Remark ID="ID_5835">
          <Description ID="735D2A25-5BE0-46BE-BD6B-FF0A5E80B502">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="20cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Dokumentation</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Als Dokumentation sind folgende voneinander unabhängige Dokumentationen zu liefern  bzw. zu erbringen:</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">A.) Brandschutzdokumentation</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">B.) Allgemeine Gewerkedokumentation </span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Alle Plan-Unterlagen als: 1 Satz Papierunterlage,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">1 CAD-Datei ( dwg, pdf ) auf Datenträger </span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Spezifikation der Dokumentationen:</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">A.) Brandschutzdokumentation</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Register 1.) </span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Auflistung sämtlicher brandschutzrelevanter Bauteile mit Angabe der Verortung.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Register 2.)</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Bescheinigungen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">- Fachbauleitererklärung</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">- Fachunternehmererklärung</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">- Übereinstimmungserklärung für den Einbau von</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Feuerabschlüssen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">In den Bescheinigungen müssen die Produkte genannt sein und die Zulassungsnummern der bauaufsichtlichen Zulassungen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Register 3.)</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Herstellerangaben von brandschutzrelevanten Bauprodukten</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Register 4.)</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abnahmebescheinigung</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">B.) Allgemeine Gewerkedokumentation ( gilt für alle Bauteile )</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Register 1.) </span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Inhaltsverzeichnis</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Register 2.)</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Bescheinigungen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">- Fachbauleitererklärung</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">- Fachunternehmererklärung</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Register 3.)</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Herstellerangaben für alle Bauprodukte</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">-Angabe der eingebauten Materialien bzw. Materialnachweise, technische Merkblätter zu den eingebauten Produkten</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Register 4.)</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abnahmebescheinigung</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">- Abnahmeprotokoll mit Mängelliste</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Register 5)</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Bedienungs- und Wartungsanweisung,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;"> </span>
               <span style="font-family:Arial;font-size:10pt;Color:rgb(0,0,255);">- entfällt</span>
               <span style="font-family:Arial;font-size:10pt;Color:rgb(178,178,178);"> </span>
              </p>
              <p style="font-family:Arial;font-size:10pt;Color:rgb(192,192,192);text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;Color:rgb(192,192,192);">Einweisungsprotokolle</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;Color:rgb(192,192,192);text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;Color:rgb(192,192,192);">- für technische Anlagen, mechanische Antriebe oder</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;Color:rgb(192,192,192);text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;Color:rgb(192,192,192);">motorische Antriebe welche ausschließlich in deutscher</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;Color:rgb(192,192,192);text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;Color:rgb(192,192,192);">Sprache erstellt sind.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;Color:rgb(192,192,192);text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;Color:rgb(192,192,192);">- Pflegeanweisungen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;Color:rgb(192,192,192);text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;Color:rgb(192,192,192);">- Wartungsvorschriften</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;Color:rgb(192,192,192);text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;Color:rgb(192,192,192);">- Wartungstermine</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;Color:rgb(192,192,192);text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;Color:rgb(192,192,192);">- Einweisungsprotokolle</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Register 6)</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Planunterlagen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">  - </span>
               <span style="font-family:Arial;font-size:10pt;Color:rgb(0,0,255);">entfällt</span>
               <span style="font-family:Arial;font-size:10pt;Color:rgb(178,178,178);"> </span>
              </p>
              <p style="font-family:Arial;font-size:10pt;Color:rgb(192,192,192);text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;Color:rgb(192,192,192);">Pläne, die gemäß Auftrag vom AN zu erstellen sind sowie vom AN zu erbringende technische Unterlagen</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Dokumentation</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Remark>
         <Item ID="ID_5836" RNoPart="0010">
          <Qty>1.000</Qty>
          <QU>psch</QU>
          <Description ID="DA75AB0A-4BF2-4606-A042-8B55492352C9">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="20cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Dokumentationsunterlagen </span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">für die erstellte Leistung, LV -positionsbezogen liefern.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Der Auftragnehmer hat vor der VOB Abnahme des Leistungsumfanges eine Dokumentation der verwendeten Materialien mit entsprechenden Nachweisen der im LV geforderten Qualitäten für den Bauherrn zu erstellen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Ohne Vorlage der Dokumentation wird keine Abnahme</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">durchgeführt.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die Unterlagen sind 1-fach spätestens 18 Werktage vor Meldung Fertigstellung der Bauleistung zur Prüfung auf Übereinstimmung mit der ausgeführten Leistung der Bauüberwachung im PDF-Format vorzulegen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Erforderliche Änderungen und Ergänzungen sind in die zur Abnahme in 1-facher Ausfertigung vorzulegenden Unterlagen einzuarbeiten.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Form der Dokumentation gemäß vorgestelltem Hinweistext.</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Dokumentation</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Item>
        </Itemlist>
       </BoQBody>
      </BoQCtgy>
      <BoQCtgy ID="ID_5628" RNoPart="02">
       <LblTx>
        <span>Stundenlohnarbeiten</span>
       </LblTx>
       <BoQBody>
        <Itemlist>
         <Remark ID="ID_5827">
          <Description ID="725162CD-A6DA-455C-A664-A1138092B892">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="14.998cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Sind Stundenlohnarbeiten vorgesehen, so werden nur die auf</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Anordnung des Auftraggebers tatsächlich erforderlichen und</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">geleisteten Stunden vergütet.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die Zuordnung erfolgt nach Art der beauftragten Tätigkeit und</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">nicht nach der Qualifikation der ausführenden Person.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die Ausführung der Stundenlohnarbeiten ist vor Beginn der</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Arbeiten anzuzeigen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Über Stundenlohnarbeiten hat der Auftragnehmer arbeitstäglich</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Stundenlohnzettel einzureichen.</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Stundenlohnarbeiten Hinweistext</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Remark>
         <Item ID="ID_5828" RNoPart="0010">
          <Qty>20.000</Qty>
          <QU>h</QU>
          <Description ID="189EC480-7790-4FD6-ACB7-C385CF215B9E">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Stundenlohnarbeiten durch Facharbeiter/-in</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">der Verrechnungssatz für die jeweilige Arbeitskraft umfasst</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">sämtliche Aufwendungen wie Lohn- und Gehaltskosten, Lohn-</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">und Gehaltsnebenkosten, Zuschläge, lohngebundene und</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">lohnabhängige Kosten, sonstige Sozialkosten, Gemeinkosten,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Wagnis und Gewinn.</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Facharbeiter/-in sämtliche Kosten/Zuschläge</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Item>
        </Itemlist>
       </BoQBody>
      </BoQCtgy>
     </BoQBody>
    </BoQCtgy>
    <BoQCtgy ID="ID_5839" RNoPart="02">
     <LblTx>
      <span>Trockenbauarbeiten - Abgehängte Decken</span>
     </LblTx>
     <BoQBody>
      <Remark ID="ID_5868">
       <Description ID="F9886359-6A37-401A-9D19-D6E038F68FE9">
        <CompleteText>
         <DetailTxt>
          <Text textWidth="14.998cm">
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
            <span style="font-family:Arial;font-size:10pt;">Hinweistext Deckenbekleidungen</span>
           </p>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
            <span style="font-family:Arial;font-size:10pt;">Die Montage der Deckenbekleidungen erfolgt in den Geschossen EG - 3.OG an waagerechten Stahlbetondecken.</span>
           </p>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
            <span style="font-family:Arial;font-size:10pt;">Im Leistungsumfang enthalten sind Deckenbekleidungen aus</span>
           </p>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
            <span style="font-family:Arial;font-size:10pt;">- Metall-Lamellendecken (teilweise mit zusätzlichen Akustikabsorbern oder Akustikplatten)</span>
           </p>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
            <span style="font-family:Arial;font-size:10pt;">- Metall-Lamellendecken als Heiz- / Kühlsystemdecken</span>
           </p>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
            <span style="font-family:Arial;font-size:10pt;">mit folgender Verteilung auf die Geschosse:</span>
           </p>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
            <span style="font-family:Arial;font-size:10pt;">Deckenbekleidung 3.OG:</span>
           </p>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
            <span style="font-family:Arial;font-size:10pt;">Lamellendecke ca. 222,00 m²</span>
           </p>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
            <span style="font-family:Arial;font-size:10pt;">Lamellendecke mit Akustikabsorbern ca. 28,00 m²</span>
           </p>
           <p style="font-family:arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;tab-stops:4.40mm;">
            <span style="font-family:Arial;font-size:10;mso-tab-count:1;">     </span>
            <span style="font-family:Arial;font-size:10pt;">-&#x3e; ca. 14,91 %</span>
           </p>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
            <span style="font-family:Arial;font-size:10pt;">Deckenbekleidung 2.OG:</span>
           </p>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
            <span style="font-family:Arial;font-size:10pt;">Lamellendecke ca. 177,50 m²</span>
           </p>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
            <span style="font-family:Arial;font-size:10pt;">Lamellendecke mit Akustikabsorbern ca. 85,00 m²</span>
           </p>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
            <span style="font-family:Arial;font-size:10pt;">Heiz- / Kühldecken ca. 77,50 m²</span>
           </p>
           <p style="font-family:arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;tab-stops:4.40mm;">
            <span style="font-family:Arial;font-size:10;mso-tab-count:1;">     </span>
            <span style="font-family:Arial;font-size:10pt;">-&#x3e; ca. 20,27 %</span>
           </p>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
            <span style="font-family:Arial;font-size:10pt;">Deckenbekleidung 1.OG:</span>
           </p>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
            <span style="font-family:Arial;font-size:10pt;">Lamellendecke ca. 410,00 m²</span>
           </p>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
            <span style="font-family:Arial;font-size:10pt;">Lamellendecke mit Akustikplatten ca. 84,00 m²</span>
           </p>
           <p style="font-family:arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;tab-stops:4.40mm;">
            <span style="font-family:Arial;font-size:10;mso-tab-count:1;">     </span>
            <span style="font-family:Arial;font-size:10pt;">-&#x3e; ca. 29,46 %</span>
           </p>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
            <span style="font-family:Arial;font-size:10pt;">Deckenbekleidung EG:</span>
           </p>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
            <span style="font-family:Arial;font-size:10pt;">Lamellendecke ca. 403,00 m²</span>
           </p>
           <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
            <span style="font-family:Arial;font-size:10pt;">Lamellendecke mit Akustikabsorbern ca. 190,00 m²</span>
           </p>
           <p style="font-family:arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;tab-stops:4.40mm;">
            <span style="font-family:Arial;font-size:10;mso-tab-count:1;">     </span>
            <span style="font-family:Arial;font-size:10pt;">-&#x3e; ca. 35,36 %</span>
           </p>
          </Text>
         </DetailTxt>
         <OutlineText>
          <OutlTxt>
           <TextOutlTxt>
            <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
             <span>Hinweistext Deckenbekleidungen</span>
            </p>
           </TextOutlTxt>
          </OutlTxt>
         </OutlineText>
        </CompleteText>
       </Description>
      </Remark>
      <BoQCtgy ID="ID_5840" RNoPart="01">
       <LblTx>
        <span>Metall-Lamellendecke</span>
       </LblTx>
       <BoQBody>
        <Itemlist>
         <Item ID="ID_5860" RNoPart="0010">
          <Qty>90.000</Qty>
          <QU>m2</QU>
          <Description ID="A0CC73D9-CDC8-4D46-8E83-E5E0EC4D5E6C">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Vorbereitung des Untergrundes für die Klebemontage Dämmplatten durch Abbürsten.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die Tragfähigkeit des vorhandenen Untergrundes und damit die Eignung für die reine Klebemontage ist vom Auftragnehmer vor Arbeitsbeginn zu prüfen.</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Vorbereitung des Untergrundes für die Klebemontage Dämmplatten</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Item>
         <Item ID="ID_5861" RNoPart="0020">
          <Qty>90.000</Qty>
          <QU>m2</QU>
          <Description ID="1C217E7E-E553-4FDD-95F9-3E6E8A176480">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Haftbrücke auftragen auf Stahlbetondecke mit lösungsmittelfreier Dispersion.</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Haftbrücke auftragen auf Stahlbetondecke</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Item>
         <Item ID="ID_5862" RNoPart="0030">
          <RefPerfNo IDRef="ID_-1"/>
          <Qty>90.000</Qty>
          <QU>m2</QU>
          <Description ID="18D00F63-E490-4E31-AFBF-1263CCEC0FC4">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Akustikdämmplatten einschließlich Verklebung an Rohdecke</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Akustikdämmplatten einschließlich Verklebung an Rohdecke</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
          <SumDescr>Yes</SumDescr>
          <SubDescr>
           <SubDNo>1</SubDNo>
           <Description ID="8142C94A-0050-40FB-B1F0-D4028ABD9DAA">
            <CompleteText>
             <DetailTxt>
              <Text textWidth="14.998cm">
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">Akustikdämmplatten an Rohdecke zur Verbesserung der Schallabsorption</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">Bereiche mit haustechnischer Installation (HLS, ELT) sind auszusparen.</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">Montage in Teilflächen in folgenden Bereichen:</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">- Abteilungsleitung 01 ca. 21,5 m² bei einer tatsächlichen Raumfläche von ca. 30 m²</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">- Büroräume 03-06 jeweils ca. 15,5 m² bei einer tatsächlichen Raumfläche von ca. 22 m²</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Dämmplatten zum Kleben an Stahlbetonrohdecke</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">Dämmplatten aus verdichteter, Kunstharz gebundener Steinwolle mit einem </span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">Schmelzpunkt &#x3e; 1000°C.</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">Anforderungen an Dämmplatten:</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">- Schallabsorption = mind. ein aw-Wert von 1,00 (Klasse A)</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">- Euroklasse A1, nicht brennbar gemäß DIN EN 13501-1</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">- Sichtseite mit schwarzer Vlieskaschierung</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">- Wärmeleitfähigkeit: 0,035 W/(mK)</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">- Feuchtigkeitsbeständig und formstabil bis  zu 100 % RH</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">- Oberfläche: geeignet für Trockenreinigung mit Tuch, weicher Bürste oder Staubsauger</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">- Gesundheitliche Unbedenklichkeit: Nachweis gemäß EU-Richtlinie 97/69</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">- Nachweis des RAL - Gütezeichens</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">- Recyclingfähigkeit: 100 %</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">Anforderungen an Kleber:</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">- Kunststoff vergüteter, nicht brennbarer Kleber auf Zementbasis gemäß DIN EN 12004,</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">- Güteklasse C2 F</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">- geeignet für die Verklebung von Steinwolleplatten</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">Verklebung der Dämmplatten:</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">- gemäß Herstellerangaben.</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Ausführung gemäß Zeichnung:</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-weight:bold;font-size:10pt;">- ARC_LP5_DEC_1OG_000_07_KON</span>
               </p>
              </Text>
             </DetailTxt>
             <OutlineText>
              <OutlTxt>
               <TextOutlTxt>
                <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                 <span>Akustikdämmplatten an Rohdecke</span>
                </p>
               </TextOutlTxt>
              </OutlTxt>
             </OutlineText>
            </CompleteText>
           </Description>
           <QtySpec>Yes</QtySpec>
          </SubDescr>
         </Item>
         <Item ID="ID_5853" RNoPart="0040">
          <RefPerfNo IDRef="ID_5852"/>
          <Qty>325.000</Qty>
          <QU>m2</QU>
          <Description ID="292F577E-5AF9-4D74-AA2C-93D3066F22F8">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Liefern und Montieren von Akustikabsorbern an Rohdecke</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Akustikabsorber 620/100/40 mm</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
          <SumDescr>Yes</SumDescr>
          <SubDescr>
           <SubDNo>1</SubDNo>
           <Description ID="ABD143F6-B3E3-4CED-A6F5-8201CF1C0E53">
            <CompleteText>
             <DetailTxt>
              <Text textWidth="14.998cm">
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">Akustikabsorber an Rohdecke zur Verbesserung der Schallabsorption</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">Montage in folgenden Bereichen:</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">- Großraum-Verwaltung EG über gesamte Raumfläche ca. 146 m²</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">- Stabsraum 2.OG ca. 85 m² bei einer tatsächlichen Raumfläche von ca. 110 m²</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Akustikabsorber</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">passend zum System der angebotenen Lamellendecke, Montage oberhalb der Tragschienen,</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">Absorber-Platten inkl. Befestigung mittels C-Profilen,</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">Brandschutzklasse A1</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">Abmessungen: ca. 620 x 100 x 40 mm bzw. gemäß angebotenem System, Farbe: schwarz</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">Akustikabsorber werden z.B. stehend oberhalb des Lamellensystems an der Rohdecke mit C-Profilen montiert.</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">Absorbierende Leistung in Verbindung mit der </span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-size:10pt;">Akustik-Lamellendecke = mind. ein aw-Wert von 0,60 (H)</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Ausführung gemäß Zeichnung:</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-weight:bold;font-size:10pt;">- ARC_LP5_DEC_EG_000_06_KON</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-weight:bold;font-size:10pt;">- ARC_LP5_DEC_2OG_000_06_KON</span>
               </p>
               <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span style="font-family:Arial;font-weight:bold;font-size:10pt;">- ARC_LP5_DEC_3OG_000_05_KON</span>
               </p>
              </Text>
             </DetailTxt>
             <OutlineText>
              <OutlTxt>
               <TextOutlTxt>
                <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                 <span>Akustikabsorber an Rohdecke</span>
                </p>
               </TextOutlTxt>
              </OutlTxt>
             </OutlineText>
            </CompleteText>
           </Description>
           <QtySpec>Yes</QtySpec>
          </SubDescr>
         </Item>
         <PerfDescr ID="ID_5841">
          <PerfNo>1</PerfNo>
          <PerfLbl>Ausführungsbeschr. Nr.1 - Metall-Lamellendecke(A)</PerfLbl>
          <Description ID="29FB3741-C5CF-4A43-BC24-390E07F64EA7">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="14.998cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Ausführungsbeschreibung Nr.1 - Metall-Lamellendecke als Akustiklamellensystem</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abgehängte Akustik Metall-Lamellendecke als Unterdecke gem. DIN 13964</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Gesamtaufbau: ca. 65 mm</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Befestigungsuntergrund: Stahlbetonflachdecke</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abhängehöhe bis UK Abhangdecke: von ca. 95 mm bis ca. 645 mm</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Tragkonstruktion aus schwarzen Lamellentragschienen, Tragschienenabstand ca. 1.000 mm</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Waagerechte und fluchtgerechte Abhängung mit Schnellspannabhängern, schwarz beschichtet</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Verbindung der Tragschienen mittels Nieten.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">An begrenzenden Bauteilen (Wände, Unterzügen, Stützen) ist das Abhängeraster so anzupassen, dass die Lamellen frei auskragen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Anschluss an aufgehende Wand mittels einer offenen Schattenfuge b = ca. 20 mm, bzw. ca. 120 mm im Bereich bauseitiges Lichtband</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Akustik-Lamellenprofil:</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">U-Profil aus Aluminium 0,5 mm, gekantet ca. 40 / 10 / 40 mm</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">mit innenseitig aufgebrachtem, schallabsorbierendem Vlies</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Achsabstand der Lamellen: 50 mm</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Lamellenlänge: von ca. 400 mm bis ca. 16.000 mm</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Längere Lamellen aus zusammengesetzten Elementen,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">kürzestes Element min. 1.200 mm.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Farbe: nach Farbpalette Hersteller, einbrennlackiert</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abmessung: U-Profil aus Aluminium</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Brandschutzklasse: Lamelle, Vlies und Tragschiene A2</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Sämtliche Einbauteile und Verbindungsmittel oberhalb der Lamelle sind tiefschwarz matt beschichtet auszuführen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Der lichte Abstand zwischen den Lamellen muss über die gesamte Bauhöhe frei sein, damit zwischen den Lamellen systemkonforme Leuchten eingebaut werden können, die höher als die Lamellen sind und somit oben überstehen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die Lamellenlängen werden in Bezug auf die Tragschienen bei der Planung individuell den Begrenzungswänden und Einbauten angepasst. Stöße der Lamellen erfolgen mittels eingebrachter systemeigener Lamellenverbinder in Verbindung mit einer Tragschiene.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Ausführung gemäß Zeichnung:</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">- ARC_LP5_DEC_EG_000_06_KON</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">- ARC_LP5_DEC_1OG_000_07_KON</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">- ARC_LP5_DEC_2OG_000_06_KON</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">- ARC_LP5_DEC_3OG_000_05_KON</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Ausführungsbeschr. Nr.1 - Metall-Lamellendecke(A)</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </PerfDescr>
         <Item ID="ID_5873" RNoPart="0050">
          <RefPerfNo IDRef="ID_5841"/>
          <Qty>39.500</Qty>
          <QU>m2</QU>
          <Description ID="EB4028DE-2C61-4909-B65A-0E8B8BE760AF">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abgehängte Deckenverkleidung als Lamellendecke gemäß Ausführungsbeschreibung Nr. 1,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Decke teilweise zur Inspektion und Wartung zu öffnen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Lamellen-Decke als Unterdecke gem. DIN 13964</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Unterkonstruktion aus Alu-Tragschiene, Abhängern und Verbindern,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">innen und außen schwarz RAL 9005 einbrennlackiert.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Befestigungsuntergrund: Stahlbeton bzw. an Stahlbeton aufgeklebte Akustikdämmplatten</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die Anpassung der Tragschienen an begrenzende Bauteile (Wände, Fassaden) ist gemäß Einzelflächenaufstellung einzukalkulieren.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abrechnung Randabschluss der Lamellen (senkrecht zu begrenzenden Bauteilen) in gesonderter Position.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">senkrechte Lamellen: Farbe RAL 9016 einbrennlackiert, bzw. nach Wahl des AG</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Prüfzeugnis nach DIN EN ISO 354:2003 ist bei Angebotsabgabe vorzulegen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">UK Abgehängte Decke: 3,00 m ü. OK FFB</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">UK Stb-Decke: von 3,10 m ü. OK FFB</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Abhanghöhe: 0,095 m</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Lamellendecke H 40 mm AH 0,095 m</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Item>
         <Item ID="ID_5874" RNoPart="0060">
          <RefPerfNo IDRef="ID_5841"/>
          <Qty>91.500</Qty>
          <QU>m2</QU>
          <Description ID="722D98C8-162B-44EF-9568-1D5925770C89">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abgehängte Deckenverkleidung als Lamellendecke gemäß Ausführungsbeschreibung Nr. 1,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Decke teilweise zur Inspektion und Wartung zu öffnen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Lamellen-Decke als Unterdecke gem. DIN 13964</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Unterkonstruktion aus Alu-Tragschiene, Abhängern und Verbindern,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">innen und außen schwarz RAL 9005 einbrennlackiert.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Befestigungsuntergrund: Stahlbeton bzw. an Stahlbeton aufgeklebte Akustikdämmplatten</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die Anpassung der Tragschienen an begrenzende Bauteile (Wände, Fassaden) ist gemäß Einzelflächenaufstellung einzukalkulieren.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abrechnung Randabschluss der Lamellen (senkrecht zu begrenzenden Bauteilen) in gesonderter Position.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">senkrechte Lamellen: Farbe RAL 9016 einbrennlackiert, bzw. nach Wahl des AG</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Prüfzeugnis nach DIN EN ISO 354:2003 ist bei Angebotsabgabe vorzulegen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">UK Abgehängte Decke: 3,085 m ü. OK FFB</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">UK Stb-Decke: 3,25 m ü. OK FFB</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Abhanghöhe: 0,165 m</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Lamellendecke H 40 mm AH 0,165 m</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Item>
         <Item ID="ID_5864" RNoPart="0070">
          <RefPerfNo IDRef="ID_5841"/>
          <Qty>1485.000</Qty>
          <QU>m2</QU>
          <Description ID="90571545-2534-4DB4-B038-C3B05CC8C873">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abgehängte Deckenverkleidung als Lamellendecke gemäß Ausführungsbeschreibung Nr. 1,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Decke teilweise zur Inspektion und Wartung zu öffnen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Lamellen-Decke als Unterdecke gem. DIN 13964</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Unterkonstruktion aus Alu-Tragschiene, Abhängern und Verbindern,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">innen und außen schwarz RAL 9005 einbrennlackiert.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Befestigungsuntergrund: Stahlbeton bzw. an Stahlbeton aufgeklebte Akustikdämmplatten</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die Anpassung der Tragschienen an begrenzende Bauteile (Wände, Fassaden) ist gemäß Einzelflächenaufstellung einzukalkulieren.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abrechnung Randabschluss der Lamellen (senkrecht zu begrenzenden Bauteilen) in gesonderter Position.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">senkrechte Lamellen: Farbe RAL 9016 einbrennlackiert, bzw. nach Wahl des AG</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Prüfzeugnis nach DIN EN ISO 354:2003 ist bei Angebotsabgabe vorzulegen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">UK Abgehängte Decke: von 2,755 bis 3,00 m ü. OK FFB</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">UK Stb-Decke: von 3,00 bis 3,25 m ü. OK FFB</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Abhanghöhe: 0,245 m</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Lamellendecke H 40 mm AH 0,245 m</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Item>
         <Item ID="ID_5877" RNoPart="0080">
          <RefPerfNo IDRef="ID_5841"/>
          <Qty>27.500</Qty>
          <QU>m2</QU>
          <Description ID="892C2FB0-275C-4175-8893-F744D9D59ACC">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abgehängte Deckenverkleidung als Lamellendecke gemäß Ausführungsbeschreibung Nr. 1,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Decke teilweise zur Inspektion und Wartung zu öffnen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Lamellen-Decke als Unterdecke gem. DIN 13964</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Unterkonstruktion aus Alu-Tragschiene, Abhängern und Verbindern,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">innen und außen schwarz RAL 9005 einbrennlackiert.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Befestigungsuntergrund: Stahlbeton bzw. an Stahlbeton aufgeklebte Akustikdämmplatten</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die Anpassung der Tragschienen an begrenzende Bauteile (Wände, Fassaden) ist gemäß Einzelflächenaufstellung einzukalkulieren.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abrechnung Randabschluss der Lamellen (senkrecht zu begrenzenden Bauteilen) in gesonderter Position.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">senkrechte Lamellen: Farbe RAL 9016 einbrennlackiert, bzw. nach Wahl des AG</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Prüfzeugnis nach DIN EN ISO 354:2003 ist bei Angebotsabgabe vorzulegen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">UK Abgehängte Decke: 3,00 m ü. OK FFB</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">UK Stb-Decke: 3,35 m ü. OK FFB</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Abhanghöhe: 0,345 m</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Lamellendecke H 40 mm AH 0,345 m</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Item>
         <Item ID="ID_5876" RNoPart="0090">
          <RefPerfNo IDRef="ID_5841"/>
          <Qty>53.000</Qty>
          <QU>m2</QU>
          <Description ID="69D07476-EFCA-4825-9501-E0F302E7F739">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abgehängte Deckenverkleidung als Lamellendecke gemäß Ausführungsbeschreibung Nr. 1,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Decke teilweise zur Inspektion und Wartung zu öffnen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Lamellen-Decke als Unterdecke gem. DIN 13964</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Unterkonstruktion aus Alu-Tragschiene, Abhängern und Verbindern,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">innen und außen schwarz RAL 9005 einbrennlackiert.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Befestigungsuntergrund: Stahlbeton bzw. an Stahlbeton aufgeklebte Akustikdämmplatten</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die Anpassung der Tragschienen an begrenzende Bauteile (Wände, Fassaden) ist gemäß Einzelflächenaufstellung einzukalkulieren.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abrechnung Randabschluss der Lamellen (senkrecht zu begrenzenden Bauteilen) in gesonderter Position.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">senkrechte Lamellen: Farbe RAL 9016 einbrennlackiert, bzw. nach Wahl des AG</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Prüfzeugnis nach DIN EN ISO 354:2003 ist bei Angebotsabgabe vorzulegen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">UK Abgehängte Decke: 2,755 m ü. OK FFB</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">UK Stb-Decke: 3,25 m ü. OK FFB</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Abhanghöhe: 0,495 m</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Lamellendecke H 40 mm AH 0,495 m</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Item>
         <Item ID="ID_5875" RNoPart="0100">
          <RefPerfNo IDRef="ID_5841"/>
          <Qty>19.000</Qty>
          <QU>m2</QU>
          <Description ID="1D0242F3-AEDD-406F-9B10-83C23E44217D">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abgehängte Deckenverkleidung als Lamellendecke gemäß Ausführungsbeschreibung Nr. 1,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Decke teilweise zur Inspektion und Wartung zu öffnen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Lamellen-Decke als Unterdecke gem. DIN 13964</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Unterkonstruktion aus Alu-Tragschiene, Abhängern und Verbindern,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">innen und außen schwarz RAL 9005 einbrennlackiert.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Befestigungsuntergrund: Stahlbeton bzw. an Stahlbeton aufgeklebte Akustikdämmplatten</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die Anpassung der Tragschienen an begrenzende Bauteile (Wände, Fassaden) ist gemäß Einzelflächenaufstellung einzukalkulieren.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abrechnung Randabschluss der Lamellen (senkrecht zu begrenzenden Bauteilen) in gesonderter Position.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">senkrechte Lamellen: Farbe RAL 9016 einbrennlackiert, bzw. nach Wahl des AG</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Prüfzeugnis nach DIN EN ISO 354:2003 ist bei Angebotsabgabe vorzulegen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">UK Abgehängte Decke: 2,605 m ü. OK FFB</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">UK Stb-Decke: 3,25 m ü. OK FFB</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Abhanghöhe: 0,645 m</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Lamellendecke H 40 mm AH 0,645 m</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Item>
         <Item ID="ID_5865" RNoPart="0110">
          <RefPerfNo IDRef="ID_5841"/>
          <Qty>1715.500</Qty>
          <QU>m2</QU>
          <Description ID="2335275A-5D74-4944-A343-28C56A1DD168">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Mehrpreis zu vorbeschriebener Position für</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Ausführung Lamellen mit Mikroperforation, sowie innenseitige Auslage mit schallabsorbierendem Vlies.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Mikroperforation: ca. 0,7 mm</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Absorption: mit innenseitigem schallabsorbierendem Vlies (schwarz)</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Erforderliche Absorptionsleistung durch Zusatzmaßnahme (Perforation und Vlies) der Metall-Lamellendecke:</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">mind. aw-Wert von 0,40(H)</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Brandschutzklasse Vlies: A2</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Stanzung zur Aufnahme in die Tragschienen darf nicht unter 10 mm Oberkante sein.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die Lamellen dürfen keine Stanzungen außerhalb des Tragschienenverlaufs aufweisen.</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Mehrpreis Ausführung Mikroperforation u. Vlies für Metall-Lam.decke</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Item>
         <PerfDescr ID="ID_5850">
          <PerfNo>2</PerfNo>
          <PerfLbl>Ausführungsbeschr. Nr.2 - Metall-Lamellendecke(A) + Heiz-/Kühlsystem</PerfLbl>
          <Description ID="7D3304C7-4A24-4320-B024-E83509B69A4A">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="14.998cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Ausführungsbeschreibung Nr.2 - Metall-Lamellendecke als Akustiklamellensystem mit zusätzlicher Ausführung als Heiz- / Kühlsystem</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abgehängte Metall-Lamellendecke wie in Ausführungsbeschreibung Nr. 1 beschrieben,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">jedoch Abhängehöhe bis UK Abhangdecke: ca. 245 mm</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">und zusätzlich mit</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Heiz- / Kühlsystem</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Heiz- / Kühlsystem passend für Lamellendecke (senkrecht), aktiv, mit senkrechten Lamellen,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Deckeneinbau luft- und schalltransparent zum Deckenhohlraum, ohne Wärmedämmung, mit Berücksichtigung von Einbauöffnungen und Aussparungen für Installationen der TGA und für Stützen, Decke teilweise zur Inspektion und Wartung zu öffnen, Befestigung Rohrsystem an vorh. Unterkonstruktion, Raumhöhe ca. 3,00 m,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">bei 20 Grad C Raumlufttemperatur, spezifische Heizleistung in W/m²: 84 (bei effektiver Heiz- / Kühlfläche von 77,50 m² und tatsächlicher Raumfläche von 250,50 m²)</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">bei 26 Grad C operativer Raumtemperatur in 1,7 m Höhe DIN EN 15251, Eintrittstemperatur 20 Grad C, max. Betriebsüberdruck 6 bar.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Verteil- bzw. Sammelleitungen quer zu Lamellen verlaufend, Rohraußendurchmesser Heizleitungen passend zur Positionierung innerhalb Lamellen. Achsmaß Abgänge an Verteil- bzw. Sammelleitungen entsprechend Achsmaß der Lamellen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">inkl. Verbindungs- und Formstücke. Verteil- und Sammelleitungen zur Befestigung an Heizkreisverteiler mittels Klemmringverschraubungen 20x2 Eurokonus.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Montagerichtlinien siehe Herstellerangaben.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Schnittstelle zu KG422 Wärmeverteilnetze: Anschluss an Verteiler.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">inkl. Druckprüfung gemäß DIN EN 806.</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Ausführungsbeschr. Nr.2 - Metall-Lamellendecke(A) + Heiz-/Kühlsystem</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </PerfDescr>
         <Item ID="ID_5878" RNoPart="0120">
          <RefPerfNo IDRef="ID_5850"/>
          <Qty>83.000</Qty>
          <QU>m2</QU>
          <Description ID="E9C1C14E-EBE2-45DA-B2EC-E85D83BB39D5">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abgehängte Deckenverkleidung als Lamellendecke gemäß Ausführungsbeschreibung Nr. 2,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Decke teilweise zur Inspektion und Wartung zu öffnen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Lamellen-Decke als Unterdecke gem. DIN 13964</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Unterkonstruktion aus Alu-Tragschiene, Abhängern und Verbindern,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">innen und außen schwarz RAL 9005 einbrennlackiert.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Befestigungsuntergrund: Stahlbeton</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die Anpassung der Tragschienen an begrenzende Bauteile (Wände, Fassaden) ist gemäß Einzelflächenaufstellung einzukalkulieren.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abrechnung Randabschluss der Lamellen (senkrecht zu begrenzenden Bauteilen) in gesonderter Position.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">senkrechte Lamellen: Farbe RAL 9016 einbrennlackiert, bzw. nach Wahl des AG</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Prüfzeugnis nach DIN EN ISO 354:2003 ist bei Angebotsabgabe vorzulegen</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">UK Abgehängte Decke: 3,00 m ü. OK FFB</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">UK Stb-Decke: 3,25 m ü. OK FFB</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-weight:bold;font-size:10pt;">Abhanghöhe: 0,245 m</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Lamellendecke H 60 mm AH 0,245 m</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Item>
         <Item ID="ID_5879" RNoPart="0130">
          <RefPerfNo IDRef="ID_5850"/>
          <Qty>83.000</Qty>
          <QU>m2</QU>
          <Description ID="993F36A4-7433-4387-B8FB-F208C9E3BB06">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Mehrpreis zu vorbeschriebener Position für</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Ausführung Lamellen mit Mikroperforation, sowie innenseitige Auslage mit schallabsorbierendem Vlies.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Mikroperforation: ca. 0,7 mm</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Absorption: mit innenseitigem schallabsorbierendem Vlies (schwarz)</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Erforderliche Absorptionsleistung durch Zusatzmaßnahme (Perforation und Vlies) der Metall-Lamellendecke:</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">mind. aw-Wert von 0,40(H)</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Brandschutzklasse Vlies: A2</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Stanzung zur Aufnahme in die Tragschienen darf nicht unter 10 mm Oberkante sein.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die Lamellen dürfen keine Stanzungen außerhalb des Tragschienenverlaufs aufweisen.</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Mehrpreis Ausführung Mikroperforation u. Vlies für Metall-Lam.decke</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Item>
         <Item ID="ID_5881" RNoPart="0140">
          <Qty>1515.000</Qty>
          <QU>m2</QU>
          <Description ID="8CA21D89-6D6C-4C29-929B-365BCCC72691">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Zulage zu den Lamellendecken für das Ausrichten / Anpassen der Deckenhöhen in Bereichen, in denen die Lamellendecken UK bündig mit Stahlbetonunterzügen ausgeführt werden sollen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Zwar sind die Abhanghöhen angegeben, diese müssen jedoch in Teilbereichen den Rohbautoleranzen angepasst werden.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">In die Position einzukalkulieren ist der zusätzliche Aufwand für das Einmessen und das Anpassen der Abhängungen in diesen Bereichen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Die erforderlichen Flächen sind vor Ausführung anzuzeigen und mit dem Architekten abzustimmen.</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Zulage Lamellendecken bündige Anschlüsse UK Betonstürze</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Item>
         <Item ID="ID_5866" RNoPart="0150">
          <Qty>770.000</Qty>
          <QU>m</QU>
          <Description ID="F4AD9B69-9875-4A48-9388-D655692ADE03">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Randabschluss Metall-Lamellendecke herstellen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">An Lichtfugen, aufgehenden Wänden.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abrechnung nur senkrecht zu Lamellen.</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Randabschluss Metall-Lamellendecke</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Item>
         <Item ID="ID_5867" RNoPart="0160">
          <Qty>30.500</Qty>
          <QU>m</QU>
          <Description ID="D4A2553F-7858-4329-A0DE-20BB82CE1798">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Randabschluss Metall-Lamellendecke an Stützen, Einbauten, etc. herstellen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abrechnung nur senkrecht zu Lamellen.</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Randabschluss Metall-Lamellendecke an Stützen, Einbauten, etc.</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Item>
         <Remark ID="ID_6066">
          <Description ID="AF59DA81-F766-47F1-BA2D-5EC24A0EA7A7">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.997cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Modulplatten mit Aussparungen für Einbauten</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Zum Einpassen von Präsenzmeldern, Lautsprechern, WLAN-Modulen etc. in das  Lamellensystem mithilfe von Modulplatten.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;"> Farbe: RAL nach Angabe AG, Farbton wie Metall-Lamellen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Ausführung der Unterkante Modulplatte mit der Lamelle bündig. </span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Arbeitshöhe der zu bearbeitenden Fläche bis 3,5 m über der Standfläche des hierfür erforderlichen Gerüstes.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">einschl. den erforderlichen Einmessarbeiten </span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">einschl. bauaufsichtlich zugelassenen Befestigungsmitteln</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Modulplatten mit Aussparungen für Einbauten</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Remark>
         <Item ID="ID_6063" RNoPart="0170">
          <Qty>180.000</Qty>
          <QU>St</QU>
          <Description ID="10C9385D-66A0-4973-862A-431C3C5B37A2">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.997cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Modulplatten Typ A - UK bündig mit UK Lamelle</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Systemkonforme Modulplatten zum Einbau in vorbeschriebene Metall-Lamellendecke.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Modulplatte 250 x 250 x 41 mm (l x b x h)</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">einschl. herstellen der Öffnung</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">rund,Durchmesser ca. 10-170 mm,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">einschl. herstellen von jeweils einer Bohrung</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Durchmesser Bohrung ca. 8 mm bis 12 mm,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">die bauseitig fixierten Elektrokabel sind durch die Löcher zu führen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">(Einbau Präsenzmelder, Lautsprecher, WLAN bauseits)</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Modulplatten Typ A - 25x25 UK bündig und Öffnung herstellen D 10-170mm</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Item>
         <Item ID="ID_5882" RNoPart="0180">
          <Qty>6.000</Qty>
          <QU>St</QU>
          <Description ID="A580B731-362F-4366-B209-308C21319E96">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Liefern und Montieren von Revisionsklappe in vorbeschriebener Lamellendecke,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">systemzugehörig,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Revisionsklappe ist durch Zurückschieben eines Riegels nach unten zu öffnen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abmessungen Reviklappe: 25 x 25 cm</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">bestehend aus:</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Tragschiene, Abhängern und Verbindern:</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">innen und außen schwarz RAL 9005 einbrennlackiert,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">senkrechten Lamellen, Farbe RAL 9016 einbrennlackiert,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">U-Profil aus Aluminium 40/10/40 mm, ca. 0,5 mm stark,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Lamellenabstand: 50 mm</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">einschl. bauaufsichtlich zugelassenen Befestigungsmitteln</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Brandschutzklasse: Lamelle und Tragschiene A2</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Sämtliche Einbauteile und Verbindungsmittel oberhalb der Lamellen sind tiefschwarz auszuführen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Position ist einschl. Herstellen der Aussparung zu kalkulieren.</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Reviklappe 25 x 25 cm in Lamellendecke</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Item>
         <Item ID="ID_6067" RNoPart="0190">
          <Qty>24.000</Qty>
          <QU>St</QU>
          <Description ID="E673A030-834F-4E15-95DF-24C1EC8531E5">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Liefern und Montieren von Revisionsklappe in vorbeschriebener Lamellendecke,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">systemzugehörig,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Revisionsklappe ist durch Zurückschieben eines Riegels nach unten zu öffnen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abmessungen Reviklappe: 30 x 30 cm</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">bestehend aus:</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Tragschiene, Abhängern und Verbindern:</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">innen und außen schwarz RAL 9005 einbrennlackiert,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">senkrechten Lamellen, Farbe RAL 9016 einbrennlackiert,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">U-Profil aus Aluminium 40/10/40 mm, ca. 0,5 mm stark,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Lamellenabstand: 50 mm</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">einschl. bauaufsichtlich zugelassenen Befestigungsmitteln</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Brandschutzklasse: Lamelle und Tragschiene A2</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Sämtliche Einbauteile und Verbindungsmittel oberhalb der Lamellen sind tiefschwarz auszuführen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Position ist einschl. Herstellen der Aussparung zu kalkulieren.</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Reviklappe 30 x 30 cm in Lamellendecke</span>
               </p>
              </TextOutlTxt>
             </OutlTxt>
            </OutlineText>
           </CompleteText>
          </Description>
         </Item>
         <Item ID="ID_5880" RNoPart="0200">
          <Qty>125.000</Qty>
          <QU>St</QU>
          <Description ID="BB6431DE-D476-40CA-A828-9FF54ECEAB21">
           <CompleteText>
            <DetailTxt>
             <Text textWidth="9.999cm">
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Liefern und Montieren von Revisionsklappe in vorbeschriebener Lamellendecke,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">systemzugehörig,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Revisionsklappe ist durch Zurückschieben eines Riegels nach unten zu öffnen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Abmessungen Reviklappe: 50 x 50 cm</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">bestehend aus:</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Tragschiene, Abhängern und Verbindern:</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">innen und außen schwarz RAL 9005 einbrennlackiert,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">senkrechten Lamellen, Farbe RAL 9016 einbrennlackiert,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">U-Profil aus Aluminium 40/10/40 mm, ca. 0,5 mm stark,</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Lamellenabstand: 50 mm</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">einschl. bauaufsichtlich zugelassenen Befestigungsmitteln</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Brandschutzklasse: Lamelle und Tragschiene A2</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Sämtliche Einbauteile und Verbindungsmittel oberhalb der Lamellen sind tiefschwarz auszuführen.</span>
              </p>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;"/>
              <p style="font-family:Arial;font-size:10pt;text-align:left;margin-top:0pt;margin-bottom:0pt;">
               <span style="font-family:Arial;font-size:10pt;">Position ist einschl. Herstellen der Aussparung zu kalkulieren.</span>
              </p>
             </Text>
            </DetailTxt>
            <OutlineText>
             <OutlTxt>
              <TextOutlTxt>
               <p style="text-align:left;margin-top:0pt;margin-bottom:0pt;">
                <span>Reviklappe 50 x 50 cm in Lamellendecke</span>
               </p>